Page 2
EZFS8*2FQ, LZFS8*2FQ
1000002234 (Rev. A - 11/14)
5
7/
8"
15
0m
m
12
1
/2
"
31
8m
m
27
"
68
6m
m
31
1
1/
32
"
79
6m
m
32
7
/8
"
83
5m
m
19
1
/3
2"
48
3m
m
8
1/
16
"
20
5m
m
13
1
5/
16
"
35
4m
m
C
HA
NG
ER
B
RA
CK
ET
A
2"
51
m
m
3
7/
8"
98
m
m
5
3/
4"
14
6m
m
7"
17
8m
m
7"
17
8m
m
F
C L
17
7
/1
6"
44
3m
m
19
"
48
3m
m
21
7
/8
"
55
6m
m
D
E
B
18
3
/8
"
46
7m
m
OR
IF
IC
E
HE
IG
HT
RI
M
H
EI
GH
T
3"
77
m
m
2"
51
m
m
28
1
3/
16
"
73
2m
m
2"
51
m
m
E
6
3/
8"
16
2m
m
6
3/
8"
16
2m
m
9/
32
"
O
H
O
LE
S
(6
)
7m
m
FI
NI
SH
ED
F
LO
OR
AD
A
RE
QU
IR
EM
EN
T
-
RE
DU
CE
H
EI
GH
T
BY
3
IN
CH
ES
F
OR
IN
ST
AL
LA
TI
ON
O
F
CH
IL
DR
EN
S
AD
A
CO
OL
ER
.
*
*
*
*
*
*
*
*
*
*
LEGEND/LEYENDA/LÉGENDE A = RECOMMENDED W
ATER SUPPL
Y LOCA
TION 3/8” O.D. UNPLA
TED COPPER TUBE CONNECT STUB WITH SHUT OFF (BY
OTHERS) 3” (76
mm
) MAXIMUM OUT FROM W
ALL
La UBICACION 3/8” O RECOMENDADA
de
ABASTECIMIENT
O DE
AGUA. D. El
TUBO del COBRE de UNPLA
TED CONECT
A
TALONARIO CON
AP
AGO (POR OTROS) 3 en. (76 Mm) el MAXIMO FUERA
DE P
ARED
L’O.D de 3/8” d’EMPLACEMENT
DE PROVISION D’EAU RECOMMANDE. LE
TUBE DE CUIVRE DE UNPLA
TED CONNECTE STUB
AVEC ETEINT
(P
AR LES
AUTRES) 3 dans. (76 mm) le MAXIMUM HORS DU MUR
B = RECOMMENDED LOCA
TION FOR W
ASTE OUTLET 1-1/4” O.D. DRAIN STUB 2” OUT FROM W
ALL
UBICACIÓN RECOMENDADA
P
ARA
EL
DRENAJE DE SALIDA
DE
AGUA, DE 1¼” DE DIÁMETRO.
El
TALONARIO 2 FUERA
DE P
ARED
EMPLACEMENT
RECOMMANDÉ POUR LE DRAIN DE D.E. 1-1/4” DE SOR
TIE D’EAU.
STUB 2 HORS DU MUR
C = 1-1/4” TRAP
NOT FURNISHED
PURGADOR DE 1¼” NO PROPORCIONADO SIPHON 1-1/4” NON FOURNI
D = ELECTRICAL
SUPPL
Y (3) WIRE RECESSED BOX
CAJA
RECESIV
A DE
ALAMBRES (3) DE SUMINISTRO ELÉCTRICO
BOÎTE ENCASTRÉE D’ALIMENT
ATION ÉLECTRIQUE (3) FILS
E = INSURE PROPER VENTILA
TION BY
MAINT
AINING 6” (152
mm
) (MIN.) CLEARANCE FROM CABINET LOUVERS T
O W
ALL.
ASEGURE UNA
VENTILACIÓN
ADECUADA
MANTENIENDO UN ESP
ACIO E 6” (152
mm
) (MÍN.) DE HOLGURA
ENTRE LA
REJILLA
DE VENTILACIÓN DEL
MUEBLE
Y LA
P
ARED
ASSUREZ-VOUS UNE BONNE VENTILA
TION EN GARDANT
6” (152
mm
) (MIN.) ENTRE LES ÉVENTS DE L
’ENCEINTE ET
LE MUR.
F = 7/16” BOL
T HOLES FOR F
ASTENING UNIT T
O W
ALL
AGUJEROS DE LAS
TUERCAS DE 7/16” P
ARA
SUJET
AR LA
UNIDAD
A LA
P
ARED
TROUS D’ÉCROUS 7/16” POUR FIXER L
’APP
AREIL
AU MUR
**NEW INST
ALLA
TIONS MUST USE GROUND F
AUL
T CIRCUIT INTERRUPTER (GFCI)
**
Las nuevas instalaciones deben utilizar el interruptor de circuito de tierra de la avería (GFCI)
**
Les nouvelles installations doivent employer l’interrupteur de circuit moulu de défaut (GFCI)
Fig. 2