Elkay EZFS8*2FQ Series Скачать руководство пользователя страница 3

Page 3

1000002234  (Rev. A - 11/14)

EZFS8*2FQ,  LZFS8*2FQ

Lower and Upper Shroud

To access the refrigeration system and plumbing connections, remove four screws from bottom 

of cooler to remove the lower shroud.  To remove the upper shroud for access to the pushbars, 

regulator, solenoid valve or other components located in the top of the unit, remove lower shroud, 

disconnect drain, remove four screws from tabs along lower edge of upper shroud, unplug two wires 

and water tube.

Switches Behind the Push Bar

The regulator, in an EZ cooler is always held fully open by the use of a single regulator nut (See Fig. 

6).  Water is not dispensed until the pushbar is depressed to activate a switch which then opens 

a solenoid valve.  When installing the regulator nut, the regulator spring must be depressed while 

turning the nut. 

Single bar units will have the same wiring as side push bar units but will not have the extra leads 

attached to sidebars.

To remove sidebars, from the inside compress the flared tabs and pull out carefully.  To reinstall side 

pushbars, the front of the pushbar is inserted first.  While keeping the switch depressed, snap the 

rear of the pushbar into position.

Service Instructions

12 - Bubbler

Assembly

Fig. 3

2

12

7

22

15

6

9

Bubbler

To remove the bubbler, first disconnect the power supply. The underside of the bubbler can be 

reached through the access panel (Item 7) on the underside of the upper shroud (Item 6). Remove 

the access panel by removing the retaining screw. To remove the bubbler, loosen locknut from the 

underside of the bubbler and remove the tubing from the quick connect fitting per the Operation Of 

Quick Connect Fittings section in the General Instructions. After servicing, replace the access panel 

and retaining screw.

15

HANGER BRACKETS & TRAP 

INSTALLATION

1)  Remove hanger bracket fastened to back of cooler by 

removing one (1) screw.

2)  Mount the hanger bracket as shown in Figure 2.  

NOTE:

  Hanger Bracket MUST be supported securely.  

Add  fixture  support  carrier  if  wall  will  not  provide 

adequate support.  Anchor hanger securely to wall 

using all six (6) 1/4 in. dia. mounting holes.

IMPORTANT:

 

  5-7/8 in. (150mm) dimension from wall to centerline 

of trap must be maintained for proper fit.

INSTALLATION OF COOLER

3)  Hang the cooler on the hanger bracket.  Be certain 

the hanger bracket is engaged properly in the slots 

on the cooler back as shown in Figure 2.

4)  Remove the four (4) screws holding the lower front 

panel at the bottom of cooler.  Remove the front panel 

by pulling straight down and set aside.

5)  Connect water inlet line--See Note 4 of General 

Instructions.

6)  Install trap.  Remove the slip nut and gasket from the 

trap and install them on the cooler waste line making 

sure that the end of the waste line fits into the trap.  

Assemble  the  slip  nut  and  gasket  to  the  trap  and 

tighten securely.

IMPORTANT:

 

If it is necessary to cut the drain, loosen 

the screw at the black rubber boot and remove tube, 

check for leaks after re-assembly.

7)  Plug in electrical power.  Unit must have

    electrical power to have water flow.

START UP

Also See General Instructions

8)  Stream height is factory set at 35 PSI.  If supply pres-

sure varies greatly from this, adjust screw located on 

the left side below push bar ass’y. on crossbar.  CW 

adjustment will raise stream and CCW adjustment will 

lower stream.  For best adjustment, stream should hit 

basin approximately 6-1/2” (165mm) from bubbler on 

the downward slope of the basin.

NOTE: 

If continuous flow occurs at the end of the com

-

pressor cycle, turn cold control screw counterclock

-

wise 1/4 turn.

9)  Replace the front panel ensuring that the metal wrap-

per is secured inside of the upper shroud.  Replace 

all four screws previously removed.

Warm, soapy water or mild household cleaning products 

can be used to clean the exterior panels of the EZ cool-

ers.  Extra caution should be used to clean the mirror 

finished stainless steel panels.  They can be easily 

scratched and should only be cleaned with mild soap and 

water or Windex glass cleaner and a clean, soft cloth.  

Use of harsh 
chemicals or petroleum based or abrasive cleaners 

will 

void the warranty.

CLEANING