Page 3
1000002234 (Rev. A - 11/14)
EZFS8*2FQ, LZFS8*2FQ
Lower and Upper Shroud
To access the refrigeration system and plumbing connections, remove four screws from bottom
of cooler to remove the lower shroud. To remove the upper shroud for access to the pushbars,
regulator, solenoid valve or other components located in the top of the unit, remove lower shroud,
disconnect drain, remove four screws from tabs along lower edge of upper shroud, unplug two wires
and water tube.
Switches Behind the Push Bar
The regulator, in an EZ cooler is always held fully open by the use of a single regulator nut (See Fig.
6). Water is not dispensed until the pushbar is depressed to activate a switch which then opens
a solenoid valve. When installing the regulator nut, the regulator spring must be depressed while
turning the nut.
Single bar units will have the same wiring as side push bar units but will not have the extra leads
attached to sidebars.
To remove sidebars, from the inside compress the flared tabs and pull out carefully. To reinstall side
pushbars, the front of the pushbar is inserted first. While keeping the switch depressed, snap the
rear of the pushbar into position.
Service Instructions
12 - Bubbler
Assembly
Fig. 3
2
12
7
22
15
6
9
Bubbler
To remove the bubbler, first disconnect the power supply. The underside of the bubbler can be
reached through the access panel (Item 7) on the underside of the upper shroud (Item 6). Remove
the access panel by removing the retaining screw. To remove the bubbler, loosen locknut from the
underside of the bubbler and remove the tubing from the quick connect fitting per the Operation Of
Quick Connect Fittings section in the General Instructions. After servicing, replace the access panel
and retaining screw.
15
HANGER BRACKETS & TRAP
INSTALLATION
1) Remove hanger bracket fastened to back of cooler by
removing one (1) screw.
2) Mount the hanger bracket as shown in Figure 2.
NOTE:
Hanger Bracket MUST be supported securely.
Add fixture support carrier if wall will not provide
adequate support. Anchor hanger securely to wall
using all six (6) 1/4 in. dia. mounting holes.
IMPORTANT:
5-7/8 in. (150mm) dimension from wall to centerline
of trap must be maintained for proper fit.
INSTALLATION OF COOLER
3) Hang the cooler on the hanger bracket. Be certain
the hanger bracket is engaged properly in the slots
on the cooler back as shown in Figure 2.
4) Remove the four (4) screws holding the lower front
panel at the bottom of cooler. Remove the front panel
by pulling straight down and set aside.
5) Connect water inlet line--See Note 4 of General
Instructions.
6) Install trap. Remove the slip nut and gasket from the
trap and install them on the cooler waste line making
sure that the end of the waste line fits into the trap.
Assemble the slip nut and gasket to the trap and
tighten securely.
IMPORTANT:
If it is necessary to cut the drain, loosen
the screw at the black rubber boot and remove tube,
check for leaks after re-assembly.
7) Plug in electrical power. Unit must have
electrical power to have water flow.
START UP
Also See General Instructions
8) Stream height is factory set at 35 PSI. If supply pres-
sure varies greatly from this, adjust screw located on
the left side below push bar ass’y. on crossbar. CW
adjustment will raise stream and CCW adjustment will
lower stream. For best adjustment, stream should hit
basin approximately 6-1/2” (165mm) from bubbler on
the downward slope of the basin.
NOTE:
If continuous flow occurs at the end of the com
-
pressor cycle, turn cold control screw counterclock
-
wise 1/4 turn.
9) Replace the front panel ensuring that the metal wrap-
per is secured inside of the upper shroud. Replace
all four screws previously removed.
Warm, soapy water or mild household cleaning products
can be used to clean the exterior panels of the EZ cool-
ers. Extra caution should be used to clean the mirror
finished stainless steel panels. They can be easily
scratched and should only be cleaned with mild soap and
water or Windex glass cleaner and a clean, soft cloth.
Use of harsh
chemicals or petroleum based or abrasive cleaners
will
void the warranty.
CLEANING