background image

ERS1*2F

Page 3

97718C (Rev. E - 09/15)

Service

For proper and safe servicing, please read these instructions completely.
       

DANGER

       •       All Service and Maintenance must be performed by an authorized service personnel. 

       •       Disconnect electrical supply to the unit before any service work to reduce risk of electrocution. 

       •       Shut off water supply serving the unit before any service work to reduce risk of water damage.
       

CAUTION

       •       Tools/Items required but not provided, for Servicing:

                     o     Safety Glasses

                     o     Protective Gloves

                     o     Hex drives.

Service: Adjustments

1.   Temperature Control: Water temperature is factory set at 50ºF ± 5º (10ºC ± 5º) under normal conditions. For colder water, adjust screw on

       item no. 10 in clockwise direction. 

Service: Inspection/Cleaning

      •     Inspect Water Chiller twice each year for proper operation and performance.

      •     Inspection of the unit will require disconnecting electrical supply, removal of panels, etc. and reassembly and return to service practices.

2.   Condenser Fan Motor

: Confirm condenser fan turns freely. If the condenser fan does not spin freely, have an authorized service personnel

      replace.

3.   Ventilation

: Cabinet louvers and condenser fins should be periodically cleaned with a brush, air hose or vacuum cleaner. Cleaning should be

      done twice each year or more frequently if needed due to environment. Excess dirt or poor ventilation can cause no cold water and

      compressor cycling on the compressor overload protector.

4.   Water Flow

: Confirm proper water flow. If water flow is slow, inspect filter or inline strainer for restriction. Replace filter cartridge if required.

      Disassemble inline strainer and clean if required.

5.   Lubrication: Motors are lifetime lubricated.

Replacement Parts: Parts  List

*INCLUDES RELAY & OVERLOAD.  IF UNDER WARRANTY, REPLACE 

WITH SAME COMPRESSOR USED IN ORIGINAL ASSEMBLY.

NOTE: All correspondence pertaining to any of the above water cool-

ers or orders for repair parts MUST include Model No. and Serial No. of 

cooler, name and part number of replacement part.

For Replacement Parts, contact your local distributor or call 1.800.834.4816

Elkay Manufacturing Co. 2222 Camden Court  - Oak Brook, IL 60523 U.S.A  - 630.574.8484

7, 14, 20

6, 9, 11

21

15

17

16

5

1, 8, 12, 13

10

3

4

19

2

18

ITEM NO.  PART NO. 

DESCRIPTION

1

22000C

BRACKET - FAN MOTOR

2

23084C

PANEL - FRONT

3

23085C

ELECTRICAL COVER

4

23086C

PANEL-RIGHT SIDE & BACK

5

23087C

LEFT SIDE

6

35768C

COVER - RELAY

7

19037000

CLIP

8

30824C

BLADE - FAN

9

36171C

OVERLOAD

10

31513C

COLD CONTROL

11*

35967C

COMPRESSOR SERVICE PACK

12

31395C

MOTOR - FAN

13 

111543043890

NUT #6 HEX (FAN MOTOR MTG)

14

100806740570

GROMMET

15

66199C

DRIER

16

61521C

CONDENSER

17

66606C

HEAT EXCHANGER

18

62031C

DRAIN PLUG

19

66363C

EVAPORATOR TANK ASSY

20

101516143550

STUD - COMPRESSOR MOUNTING

21

36166C

RELAY

Отзывы: