background image

Filtered Undercounter Cooler 

Carbonator 

4B0004 

Product Manual

 

S18 Undercounter Chiller 

Technical Support

[email protected]

 

(800) 288-1891 

Содержание S18

Страница 1: ...Filtered Undercounter Cooler Carbonator 4B0004 Product Manual S18 Undercounter Chiller Technical Support wltechsupport quenchwater com 800 288 1891...

Страница 2: ...n working with high pressure carbon dioxide and in no cases should the maximum operating pressure of 4bar be exceeded The over counter unit uses R290 Care 40 Propane refrigerant Below are some safety...

Страница 3: ...let 1 4 John Guest Speedfit Water Inlet 3 8 John Guest Speedfit Bath Overflow 1 2 John Guest Speedfit CO2 Gas Inlet 1 4 John Guest Speedfit Recirc Return Recirc Out Sparkling Out Still Out 3 8 John Gu...

Страница 4: ...he rear Ensure that the supplied base guard is fitted to the underside of the unit Fill the bath with water To do this remove the lid from the unit and remove the bath inspection cover Min and Max wat...

Страница 5: ...lose At this stage re fit the lid and filter housing cover Turn on the electrical supply After a short delay the fridge system will activate check for air exhausting to the rear of the machine and the...

Страница 6: ...Installation and Commissioning Page 6 of 16 Mains Power In On Off Switch Control Board Carbonator Can Pressure Relief Valve Water Flow Meter...

Страница 7: ...Schematics Page 7 of 16 Electrical Circuit Water Circuit...

Страница 8: ...e the cloth and remove excess water Clean the dispense components by wiping the cloth over the entire area re submerging the cloth as necessary Rinse the cloth in clean warm water and wipe off excess...

Страница 9: ...that has been soaked in clean warm water Dry dispense component with disposable paper towels Refit all dispense components General Cleaning Parts not in contact with food products Important It is rec...

Страница 10: ...ed either using a pressurised container or by using a syphon In the latter case the sanitiser fluid needs to be held at a height sufficient to allow fluid to flow through the chiller Flush through app...

Страница 11: ...on OFF Water pump timeout ON 1 second OFF 2 second Timeout and protection events can be reset by cycling mains power off then on The cause of the event should be investigated and corrected Symptom Pos...

Страница 12: ...replace as necessary Air in Carbonator Can Purge the carbonator can by operating the flush switch until empty and CO2 is dispensed for 5 seconds Residue in Carbonator Can After prolonged use a surface...

Страница 13: ...3 of 16 1A6135 LED Filter Assembly 1A6139 Front Panel Assembly 3B7870 Side Panel 3B7870 Side Panel 1A6138 Lid 3B7868 Rear Panel 1A6209 Thermostat 3B7886 Base Guard 3B3201 Fan 1A6050 Pump Assy 1A4674 P...

Страница 14: ...Spare Parts Page 14 of 16 1A6002 Agitator 3B6223 Cooling Coil 1A5811 Carb Can 1A6065 PCB...

Страница 15: ...tant This unit must be transported in an upright position As with all refrigeration systems irreparable damage can be caused by laying the unit on its side or even transporting upside down Where the u...

Страница 16: ...Page 16 of 16...

Отзывы: