1000004006  (Rev. A - 08/2017)

EFRC12C_2AWR

Service

• 

Safety Glasses

• 

Protective gloves

• 

5/16” (8mm) Hex Socket or Flathead Screwdriver

• 

3/32” (2.4mm) Hex Key

Service: Inspection/Cleaning

• 

Inspect Cooler twice each year for proper operation and performance.

• 

Inspection of the unit will require disconnecting electrical supply, removal of panels, etc. and reassembly and return to service practices.

1.  Cleaning: Warm, soapy water or mild household cleaning products can be used to clean the exterior panels. Extra caution should be used to 

clean the mirror finished stainless steel panels. They can be easily scratched and should only be cleaned with mild soap and water or Windex 

glass cleaner and a clean, soft cloth. Use of harsh chemicals or petroleum based or abrasive cleaners will void the warranty.

2.  Ventilation: Cabinet louvers and condenser fins should be periodically cleaned with a brush, air hose or vacuum cleaner. Cleaning should be 

done twice each year or more frequently if needed due to environment. Excess dirt or poor ventilation can cause no cold water and compressor 

cycling on the compressor overload protector.

3.  Water Flow: Confirm proper water flow. If water flow is slow, inspect filter or inline strainer for restriction. Replace filter cartridge if required.  

Disassemble inline strainer and clean if required.

4.  Actuation of Quick Connect Water Fittings: Cooler is provided with lead-free connectors which utilize o-ring water seal. To remove tubing from 

the fitting, relieve water pressure, push in on the gray collar before pulling on the tubing. To insert tubing, push tube straight into fitting until it 

reaches a positive stop, approximately 3/4” (19mm).  See Figure 8. 

NOTE: WATER FLOW

DIRECTION

Figure 7

TUBE IS SECURED

IN POSITION

SIMPLY PUSH IN

TUBE TO ATTACH

PUSH IN COLLET

TO RELEASE TUBE

PUSHING TUBE IN BEFORE

PULLING IT OUT HELPS TO

RELEASE TUBE

Figure 8

For Replacement Parts, contact your local distributor or call 1.800.834.4816

Elkay Manufacturing Co. 2222 Camden Court  Oak Brook, IL 60523 U.S.A – 630.574.8484

For proper and safe servicing, please read these instructions completely.

DANGER

• 

All Service and Maintenance must be performed by an authorized service personnel. 

• 

Disconnect electrical supply to the unit before any service work to reduce risk of electrocution. 

• 

Shut off water supply serving the unit before any service work to reduce risk of water damage.

CAUTION

• 

Tools/Items required but not provided, for Servicing:

1/4" O.D. TUBE

WATER INLET

FROM CHILLER

IN-LINE 

STRAINER 

(PROVIDED)

3/8" (9.5mm) O.D. 

UNPLATED COPPER 

TUBE (NOT PROVIDED)

BUILDING WATER SUPPLY

WATER SHUT-OFF VALVE

(NOT PROVIDED)

REPLACEMENT

 

PARTS LIST

ITEM NO.

PART NO.

DESCRIPTION

1

1000004196

Kit - Push Button Assy

2

40480C

Precooler

3

40038C

Strainer

4

62084C

Tube Assy - GF

5

56092C

Poly Tubing 48”(Cut to Length)

6

40619C

Ferrule

7

70151C

Gasket

8

70234C

Washer

9

1000004289

Bubbler Assy

10

40299C

Drain - 1/2”

11

1000004175

Glass Filler

12

50258C

Washer

13

61099C

Connector Assy

14

1000001994

Kit - Tee 1/4 (3 Pack)

15

1000002162

Kit - Union 1/4 (3 Pack)

16

1000004069

Strainer

17

110669443890

Screw - #10 x .63 PHSM

18

74070030

Screw - #8 x 1.00 PH

19

74070032

Speed Nut - #8

20

70567C

Clip - Speed

21

EFRCDF

Fountain - GF

22

EG23

Grill

23

31525028

O-ring

24

75580C

Locknut

Содержание EFRCM122FKWR

Страница 1: ...te Electrical supply must have Ground Fault Circuit Interrupter GFCI protection A means for disconnecting electrical supply to the unit must be incorporated in the fixed wiring in accordance with wiring rules This is to allow electrical disconnection of the unit from electrical supply after installation WARNING For use with clean clear potable drinking water only Do not use with water that is micr...

Страница 2: ...r before connecting to refrigeration package The furnished strainer Item 16 should be added to the supply line 7 Connect the refrigeration package to the supply line service stop valve Connect supplied fountain internal plumbing tubes as shown in figure 6 Remove any burrs from water tubes before inserting into fittings See Figs 7 and 8 DO NOT SOLDER TUBES INSERTED INTO THE STRAINER AS DAMAGE TO TH...

Страница 3: ...UNPLATED COPPER TUBE CONNECT STUB 1 1 2 38mm OUT FROM WALL SHUT OFF BY OTHERS BOTH SIDES B RECOMMENDED LOCATION FOR WASTE OUTLET 1 1 4 O D DRAIN BOTH SIDES C ELECTRICAL SUPPLY LOCATION BOTH SIDES NOTES 1 THERE ARE HOLES AND KNOCKOUTS PROVIDED ON EACH SIDE OF THE MOUNTING BOX THAT ARE INTENDED TO BE USED TO MOUNT THE BOX USE SIX SCREWS OR BOLTS NOT PROVIDED ...

Страница 4: ...7 EFRC12C_2AWR 1 3 7 10 12 10 8 13 7 NOTE WHEN INSTALLING REPLACEMENT BUB BLER AND PEDESTAL TIGHEN LOCKNUT ONLY TO HOLD PARTS SNUG IN POSITION DO NOT OVER TIGHTEN BASIN BASIN 2 6 Locknut 9 Adjustment Screw Figure 2 Figure 3 Figure 4 ...

Страница 5: ...Page 5 1000004006 Rev A 08 2017 EFRC12C_2AWR 4 24 23 11 14 16 15 15 5 Figure 5 Figure 6 ...

Страница 6: ...y collar before pulling on the tubing To insert tubing push tube straight into fitting until it reaches a positive stop approximately 3 4 19mm See Figure 8 NOTE WATER FLOW DIRECTION Figure 7 TUBE IS SECURED IN POSITION SIMPLY PUSH IN TUBE TO ATTACH PUSH IN COLLET TO RELEASE TUBE PUSHING TUBE IN BEFORE PULLING IT OUT HELPS TO RELEASE TUBE Figure 8 For Replacement Parts contact your local distributo...

Отзывы: