background image

Page 3

1000004006  (Rev. A - 08/2017)

EFRC12C_2AWR

Figure 1 (Rough-In)

FINISHED FLOOR LINE

EFRCM122FKWR ROUGH-IN

LEGEND:

A = RECOMMENDED WATER SUPPLY LOCATION 3/8” O.D. UNPLATED COPPER TUBE CONNECT   

      STUB 1-1/2” (38mm) OUT FROM WALL, SHUT OFF BY OTHERS (BOTH SIDES).

B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4” O.D. DRAIN (BOTH SIDES).

C = ELECTRICAL SUPPLY LOCATION (BOTH SIDES).

NOTES:

 1. THERE ARE HOLES AND KNOCKOUTS PROVIDED ON EACH SIDE OF THE MOUNTING BOX THAT

      ARE INTENDED TO BE USED TO MOUNT THE BOX. USE SIX SCREWS OR BOLTS (NOT PROVIDED).

Содержание EFRCM122FKWR

Страница 1: ...te Electrical supply must have Ground Fault Circuit Interrupter GFCI protection A means for disconnecting electrical supply to the unit must be incorporated in the fixed wiring in accordance with wiring rules This is to allow electrical disconnection of the unit from electrical supply after installation WARNING For use with clean clear potable drinking water only Do not use with water that is micr...

Страница 2: ...r before connecting to refrigeration package The furnished strainer Item 16 should be added to the supply line 7 Connect the refrigeration package to the supply line service stop valve Connect supplied fountain internal plumbing tubes as shown in figure 6 Remove any burrs from water tubes before inserting into fittings See Figs 7 and 8 DO NOT SOLDER TUBES INSERTED INTO THE STRAINER AS DAMAGE TO TH...

Страница 3: ...UNPLATED COPPER TUBE CONNECT STUB 1 1 2 38mm OUT FROM WALL SHUT OFF BY OTHERS BOTH SIDES B RECOMMENDED LOCATION FOR WASTE OUTLET 1 1 4 O D DRAIN BOTH SIDES C ELECTRICAL SUPPLY LOCATION BOTH SIDES NOTES 1 THERE ARE HOLES AND KNOCKOUTS PROVIDED ON EACH SIDE OF THE MOUNTING BOX THAT ARE INTENDED TO BE USED TO MOUNT THE BOX USE SIX SCREWS OR BOLTS NOT PROVIDED ...

Страница 4: ...7 EFRC12C_2AWR 1 3 7 10 12 10 8 13 7 NOTE WHEN INSTALLING REPLACEMENT BUB BLER AND PEDESTAL TIGHEN LOCKNUT ONLY TO HOLD PARTS SNUG IN POSITION DO NOT OVER TIGHTEN BASIN BASIN 2 6 Locknut 9 Adjustment Screw Figure 2 Figure 3 Figure 4 ...

Страница 5: ...Page 5 1000004006 Rev A 08 2017 EFRC12C_2AWR 4 24 23 11 14 16 15 15 5 Figure 5 Figure 6 ...

Страница 6: ...y collar before pulling on the tubing To insert tubing push tube straight into fitting until it reaches a positive stop approximately 3 4 19mm See Figure 8 NOTE WATER FLOW DIRECTION Figure 7 TUBE IS SECURED IN POSITION SIMPLY PUSH IN TUBE TO ATTACH PUSH IN COLLET TO RELEASE TUBE PUSHING TUBE IN BEFORE PULLING IT OUT HELPS TO RELEASE TUBE Figure 8 For Replacement Parts contact your local distributo...

Отзывы: