1000004006  (Rev. A - 08/2017)

EFRC12C_2AWR

Refrigerated bottle filling station delivers chilled, clean potable drinking water with push button activated water flow. Recessed, in-wall mounting 

frame houses the remote chiller and provideds a means for mounting bottle filler.

• 

Electrical: 220Vac, 50Hz, (See Nameplate for Amperage),  

1 phase.

• 

Ambient Air Temperature: 50-100.4 °F (10-38 °C).

• 

Water Pressure: 20-100 psig (0.14-0.69 MPa).

• 

Maximum Water Temperature: 90 °F (32 °C).

• 

Ingress Protection: IP2x

• 

Refrigerant: HFC-R134a

• 

Four Indoor Commercial Use Only

DANGER

 

– Indicates death or serious injury will result if proper precautions are not taken.

WARNING

 – Indicates death, serious injury or property damage can result if proper precautions are not taken.

CAUTION

 – Indicates some injury or property damage may result if proper precautions are not taken.

Definitions

Authorized Service Personnel

 – Factory trained personnel or personnel having working knowledge of electrical, 

plumbing, and machine (appliance) maintenance procedures.

Safety

DANGER

• 

Please read these instructions completely before starting the installation or performing any service. Failure to follow the instructions and safety 

precautions in this manual can result in serious injury or death.

• 

After installation, keep these instructions in a safe location for future reference.

• 

Electric supply must be identical in voltage, cycle, and phase to that specified on nameplate.

• 

Electrical supply must have Ground Fault Circuit Interrupter (GFCI) protection. 

• 

A means for disconnecting electrical supply to the unit must be incorporated in the fixed wiring in accordance with wiring rules. This is to allow 

electrical disconnection of the unit from electrical supply after installation. 

WARNING

• 

For use with clean, clear potable drinking water only. Do not use with water that is microbiologically unsafe or of unknown quality without 

adequate disinfection before the system.

• 

Installation and connection to water and electrical mains must be in compliance with local and national laws. 

• 

All Installation and Service work must be performed by an authorized service personnel.

CAUTION

• 

This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory, or mental capabilities 

or lack of experience and knowledge if they have been given supervision or instructions concerning use of the appliance in a safe way and 

understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children 

without supervision.

• 

To prevent a metallic taste or increased metal content in the water due to an electrolysis process caused by electrical feedback from the 

grounding of electrical equipment to water supply and water waste mains, connect to these mains using non-conductive materials. The provided 

solenoid valve regulator assembly meets this requirement.

Description

Ratings

SEE FIG. 7

SEE FIG. 8

SEE FIG. 9

22

18, 19

17, 20

21

Installation / Care / Use Manual

Original Instructions

Model: EFRCM122FKWR

Содержание EFRCM122FKWR

Страница 1: ...te Electrical supply must have Ground Fault Circuit Interrupter GFCI protection A means for disconnecting electrical supply to the unit must be incorporated in the fixed wiring in accordance with wiring rules This is to allow electrical disconnection of the unit from electrical supply after installation WARNING For use with clean clear potable drinking water only Do not use with water that is micr...

Страница 2: ...r before connecting to refrigeration package The furnished strainer Item 16 should be added to the supply line 7 Connect the refrigeration package to the supply line service stop valve Connect supplied fountain internal plumbing tubes as shown in figure 6 Remove any burrs from water tubes before inserting into fittings See Figs 7 and 8 DO NOT SOLDER TUBES INSERTED INTO THE STRAINER AS DAMAGE TO TH...

Страница 3: ...UNPLATED COPPER TUBE CONNECT STUB 1 1 2 38mm OUT FROM WALL SHUT OFF BY OTHERS BOTH SIDES B RECOMMENDED LOCATION FOR WASTE OUTLET 1 1 4 O D DRAIN BOTH SIDES C ELECTRICAL SUPPLY LOCATION BOTH SIDES NOTES 1 THERE ARE HOLES AND KNOCKOUTS PROVIDED ON EACH SIDE OF THE MOUNTING BOX THAT ARE INTENDED TO BE USED TO MOUNT THE BOX USE SIX SCREWS OR BOLTS NOT PROVIDED ...

Страница 4: ...7 EFRC12C_2AWR 1 3 7 10 12 10 8 13 7 NOTE WHEN INSTALLING REPLACEMENT BUB BLER AND PEDESTAL TIGHEN LOCKNUT ONLY TO HOLD PARTS SNUG IN POSITION DO NOT OVER TIGHTEN BASIN BASIN 2 6 Locknut 9 Adjustment Screw Figure 2 Figure 3 Figure 4 ...

Страница 5: ...Page 5 1000004006 Rev A 08 2017 EFRC12C_2AWR 4 24 23 11 14 16 15 15 5 Figure 5 Figure 6 ...

Страница 6: ...y collar before pulling on the tubing To insert tubing push tube straight into fitting until it reaches a positive stop approximately 3 4 19mm See Figure 8 NOTE WATER FLOW DIRECTION Figure 7 TUBE IS SECURED IN POSITION SIMPLY PUSH IN TUBE TO ATTACH PUSH IN COLLET TO RELEASE TUBE PUSHING TUBE IN BEFORE PULLING IT OUT HELPS TO RELEASE TUBE Figure 8 For Replacement Parts contact your local distributo...

Отзывы: