background image

PAGE 3

97344C (7/98)

EFOA8*1D

NOTE:

WHEN INSTALLING REPLACEMENT

BUBBLER AND PEDESTAL, TIGHTEN

NUT (ITEM 12) ONLY TO HOLD

PARTS SNUG IN POSITION.

DO NOT OVER TIGHTEN.

FIG. 4

BASIN

9

10

11

12

8

WIRING DIAGRAM

This Drawing is merely for illustrating the

components of the electrical sytem.

SENSOR RANGE ADJUSTMENT

:  The electronic sensor used in this cooler is factory pre-set for a "visual" range of 36

     inches (914 mm).  If actual range varies greatly from this or a different setting is desired, follow the range adjustment

     procedure below:

A.  Remove front panel of cooler.

B.  Using a small tip screwdriver, rotate range adjustment screw clockwise to increase range and counterclockwise to

     decrease range (See Fig. 3).

     CAUTION

:  Complete range of sensor (24-28 inches/610-711mm) is only one turn of the adjusting screw.

C.  Replace front panel.

SENSOR CONTROL

:  If sensor fails to operate valve mechanism or operates erratically, check the following.

A.  Ensure there are no obstructions within a 40 inch (1016mm) radius in front of cooler.

B.  Check wire connections at the solenoid valve and sensor.  

CAUTION

:  Make sure unit is unplugged before checking any

     wiring.

C.  Ensure proper operation of solenoid valve.  If there is an audible clicking sound yet no water flows, look for an obstruction

     in the valve itself or elsewhere in the water supply line.

RANGE ADJUSTMENT SCREW

30

6

31

32

3

4

5

2

1

TO PRECOOLER

33

TO SOLENOID VALVE (ITEM 32)

FIG. 3

TO EVAP. ASSY.(ITEM 29)

Содержание EFOA8 1D

Страница 1: ...PAGE 1 97344C 7 98 EFOA8 1D With FLEXI GUARD Installation Care Use Manual USES HFC 134A REFRIGERANT FIG 1 7 27 15 16 14 SEE FIG 4 26 30 28 22 23 25 17 18 19 20 21 34 13 29 32 33 31 24 ...

Страница 2: ...GAR DENTRO DE ESTA ÁREA ON PEUT PLACER LA TUYAUTERIE DANS CETTE RÉGION LEGEND LEYENDA LÉGENDE A RECOMMENDED WATER SUPPLY LOCATION 3 8 O D UNPLATED COPPER TUBE CONNECT STUB 1 1 2 IN 38mm OUT FROM WALL SHUT OFF BY OTHERS SE RECOMIENDA UBICAR EL TUBO CORTO DE CONEXIÓN AL TUBO DE COBRE SIN CHAPAR DE 3 8 DE DIÁM EXT A 1 1 2 38mm FUERA DE LA LLAVE DE PASO EN LA PARED COLOCADA POR TERCEROS EMPLACEMENT RE...

Страница 3: ...t screw clockwise to increase range and counterclockwise to decrease range See Fig 3 CAUTION Complete range of sensor 24 28 inches 610 711mm is only one turn of the adjusting screw C Replace front panel SENSOR CONTROL If sensor fails to operate valve mechanism or operates erratically check the following A Ensure there are no obstructions within a 40 inch 1016mm radius in front of cooler B Check wi...

Страница 4: ...y Pedestal Bubbler Locknut Cold Control Power Cord Condenser Fan Shroud Fan Motor Fan Blade Fan Bracket Fan Blade Nut Drier Compressor Serv Pak Overload Relay Assembly Receptor Drain Electrical Shield Strainer Precooler Heat Exchanger Evaporator Regulator Bracket Sensor clear Solenoid Valve Assembly Cross Brace Screw Evaporator Mtg 40116C 70254C 15005C 61313C 40045C 50986C 27316C 51349C 40322C 509...

Отзывы: