background image

PAGE 2

97344C (7/98)

EFOA8*1D

FIG. 2

FINISHED FLOOR

PISO ACABADO PLANCHER FINI

E = INSURE PROPER VENTILA

TION BY 

MAINT

AINING 4" (102mm) (MIN.) CLEARANCE FROM CABINET LOUVERS T

O

 W

ALL.

ASEGURE UNA

 VENTILACIÓN 

ADECUADA

 MANTENIENDO UN ESP

ACIO E 4" (102mm) (MÍN.) DE HOLGURA

 ENTRE LA

REJILLA

 DE VENTILACIÓN DEL

 MUEBLE 

LA

 P

ARED

ASSUREZ-VOUS UNE BONNE VENTILA

TION EN GARDANT

 4" (102mm) (MIN.) ENTRE LES ÉVENTS DE L

’ENCEINTE ET

 LE

MUR.

F = POWER CORD 4 FEET (1219mm) LONG

CABLE ELÉCTRICO DE 4 PIE (1219mm), DE LARGO CORDON D’ALIMENT

ATION 4' (1219mm)

G = 

A

LT

. ELECTRICAL

 OUTLET 

LOCA

TION

UBICACIÓN 

AL

T.

 DE LA

 T

O

M

A DE ELECTRICIDAD

EMPLACEMENT

 AL

TERNA

TIF DE LA

 PRISE DE COURANT

H = PLUMBING ROUGH-IN CAN BE LOCA

TED 

ANYWHERE WITHIN THIS 

AREA.

SE PUEDE COLOCAR EL

 DESBASTE DE LA

 TUBERÍA

 EN CUALQUIER LUGAR DENTRO DE EST

A ÁREA.

ON PEUT

 PLACER LA

 T

U

YAUTERIE DANS CETTE RÉGION.

LEGEND/LEYENDA/LÉGENDE A = RECOMMENDED W

ATER SUPPL

LOCA

TION 3/8 O.D. UNPLA

TED COPPER TUBE CONNECT STUB 1-1/2 IN. (38

m

m

) OUT

FROM WALL SHUT OFF BY OTHERS

 SE R

E

C

O

M

IEN

DA

 UBICAR EL

 TUBO COR

TO

 DE CONEXIÓN 

AL

 TUBO DE COBRE SIN CHAP

AR DE 3/8" DE DIÁM. EXT

. A

 1-1/2"

(3

8m

m

) FUERA

 DE LA

 LLA

VE DE P

ASO EN LA

 P

ARED COLOCADA

 POR 

TERCEROS.

        EMPLACEMENT

 RECOMMANDÉ D'ALIMENT

ATION EN EAU P

AR 

TUBE EN CUIVRE NON PLAQUÉ DE 3/8 PO. (9,5 m

m

) D.E.

CONNECT

ANT

 UNE T

U

YAUTERIE DE 1-1/2 PO. (38m

m

) DEPUIS LE ROBINET

 D'ARRÊT

 FOURNI P

AR D'AUTRES.

RECOMMENDED 

LOCA

TION FOR W

ASTE OUTLET 1-1/4” O.D.  DRAIN

 UBICACIÓN RECOMENDADA

 P

A

R

A EL

 DRENAJE DE SALIDA

 D

E

 AGUA, DE 1¼” DE DIÁMETRO.

EMPLACEMENT RECOMMANDÉ POUR LE DRAIN DE D.E. 1-1/4" DE SORTIE D’EAU.

C = 1-1/4 TRAP NOT FURNISHED**

PURGADOR DE 1¼ NO PROPORCIONADO** SIPHON 1-1/4 NON FOURNI**

D = ELECTRICAL

 OUTLET 

LOCA

TION

UBICACIÓN DE LA TOMA DE ELECTRICIDAD EMPLACEMENT DE LA PRISE DE COURANT

Содержание EFOA8 1D

Страница 1: ...PAGE 1 97344C 7 98 EFOA8 1D With FLEXI GUARD Installation Care Use Manual USES HFC 134A REFRIGERANT FIG 1 7 27 15 16 14 SEE FIG 4 26 30 28 22 23 25 17 18 19 20 21 34 13 29 32 33 31 24 ...

Страница 2: ...GAR DENTRO DE ESTA ÁREA ON PEUT PLACER LA TUYAUTERIE DANS CETTE RÉGION LEGEND LEYENDA LÉGENDE A RECOMMENDED WATER SUPPLY LOCATION 3 8 O D UNPLATED COPPER TUBE CONNECT STUB 1 1 2 IN 38mm OUT FROM WALL SHUT OFF BY OTHERS SE RECOMIENDA UBICAR EL TUBO CORTO DE CONEXIÓN AL TUBO DE COBRE SIN CHAPAR DE 3 8 DE DIÁM EXT A 1 1 2 38mm FUERA DE LA LLAVE DE PASO EN LA PARED COLOCADA POR TERCEROS EMPLACEMENT RE...

Страница 3: ...t screw clockwise to increase range and counterclockwise to decrease range See Fig 3 CAUTION Complete range of sensor 24 28 inches 610 711mm is only one turn of the adjusting screw C Replace front panel SENSOR CONTROL If sensor fails to operate valve mechanism or operates erratically check the following A Ensure there are no obstructions within a 40 inch 1016mm radius in front of cooler B Check wi...

Страница 4: ...y Pedestal Bubbler Locknut Cold Control Power Cord Condenser Fan Shroud Fan Motor Fan Blade Fan Bracket Fan Blade Nut Drier Compressor Serv Pak Overload Relay Assembly Receptor Drain Electrical Shield Strainer Precooler Heat Exchanger Evaporator Regulator Bracket Sensor clear Solenoid Valve Assembly Cross Brace Screw Evaporator Mtg 40116C 70254C 15005C 61313C 40045C 50986C 27316C 51349C 40322C 509...