Positioning
CAREFUL POSITIONING IS ESSENTIAL TO 
OBTAIN OPTIMUM PERFORMANCE.

Use the detection range to determine a 
suitable location for the sensor. When 
locating the position of the units, ensure 
the sensor is not subjected to bright or 
direct sunlight or in areas with high 
refl ective surfaces. Do not site units on a
vibrating surface, or near forced air 

Diagram 3

Please note:

 The black bar denotes the 

position of the dip switch. Dip switch 
4 is only used for Setting Automatic 
(150 Lux) or Manual Lux ONLY.

Diagram 2

Diagram 2

heating and ventilation. They should not 
be placed within 1 metre of the load.

Sensors work when objects move across 
their fi eld of view. Position the sensor 
where people will be detected walking 
across the zones rather than towards the 
zones identifi ed in Diagram 1. Adjust 
sensitivity to suit the area that the sensor 
has been installed in.

2

INSTRUCTION GUIDE

|

CEILING MOUNT PIR TIMER – 3 WIRE

 Auto Lux    Manual Lux                Test Mode               2 mins         5 mins        10 mins       15 mins       20 mins      30 mins        60mins

                                                         10 secs             

ON      DIP

4
3
2
1

ON      DIP

4
3
2
1

ON      DIP

4
3
2
1

ON      DIP

4
3
2
1

ON      DIP

4
3
2
1

ON      DIP

4
3
2
1

ON      DIP

4
3
2
1

ON      DIP

4
3
2
1

ON      DIP

4
3
2
1

ON      DIP

4
3
2
1

Diagram 4

Time Settings (Test Mode to 60 mins).

LIVE IN

LIVE OUT

NEUTRAL

Wiring diagram for a single unit.

Wiring diagram for a single unit.

DIL 

SWITCHES

7-10 metres approx

2.4 metres

7-10 metres approx

.

CEILING

FLOOR

Diagram 1

Removing the Sensor from
Surface Mount Box.

Squeeze 
the housing 
on either side as shown here.

Содержание 374B-1

Страница 1: ...ff the load after the adjustable time period has elapsed If infra red heat is detected again during the timing period the timing sequence will restart The unit has a lux level adjustment and Auto Lux function which measures the ambient light levels and prevents lighting being switched on when there is sufficient lighting in the room There is sensitivity adjustment and test mode function added for ...

Страница 2: ...osition of the dip switch Dip switch 4 is only used for Setting Automatic 150 Lux or Manual Lux ONLY Diagram 2 Diagram 2 heating and ventilation They should not be placed within 1 metre of the load Sensors work when objects move across their field of view Position the sensor where people will be detected walking across the zones rather than towards the zones identified in Diagram 1 Adjust sensitiv...

Страница 3: ...tical position and insert unit into the hole Release unit ensuring arms are securely in place For surface mounting fit surface mount cup onto ceiling or conduit terminal box and return connected PIR into surface mount cup Step 4 Remove the fascia by turning anti clockwise to show the lux pot sensitivity pot and the timing lux Dip switches Please adjust the Lux Level and Sensitivity potentiometer g...

Страница 4: ...ximately 1 minute to initialise and will flash rapidly after the mains power is first applied to allow the sensor to learn its environment The load will be ON after 7 seconds initially then switch off after 1 minute if there is no detection in the zones Operation of the Unit In standard operation the PIR will now sense infra red heat when a person or source of heat passes through the detection zon...

Отзывы: