Installation Steps
IT IS ESSENTIAL THAT YOU FOLLOW 
CLOSELY STEPS 1 TO 8 OF THE MOUNTING 
AND INSTALLATION INSTRUCTIONS 
BELOW. FAILURE TO DO SO WILL 
INVALIDATE THE WARRANTY.

Step 1 

Please ensure that you position the PIR in 
the correct place by reading the Positioning 
section of these instructions. For flush 
mounting cut a clean hole measuring 
64mm in diameter in the chosen area for 
the sensor. For surface mounting attach 
surface mount cup to ceiling with
connection cable hanging through the 
middle. Seal any large holes on ceiling to 
prevent air current activation.

Step 2

Ensure that the mains power to the circuit 
is switched off. Ensure terminal cover 
and cable clamp are correctly fitted with 
screws supplied. Place the Live In into the 
Terminal marked Live In and the switched 
Live Out into the Live Out terminal.  
Place the neutral into the connection 
marked N for neutral. Please note that it is 
essential that the Live In wire and the 
switch Live Out and Neutral are identified 
prior to commencing installation. 
To connect multiple units connect the live 
switch live and neutrals as shown in 
Diagram 2. Turn off mains supply for 
installation as live working is not 
recommended and can damage the unit.

Step 3

For flush mounting fold the two arms up 
into the vertical position and insert unit 
into the hole. Release unit ensuring arms 
are securely in place. For surface mounting 
fit surface mount cup onto ceiling or 

conduit terminal box and return connected 
PIR into surface mount cup.

Step 4

Remove the fascia by turning anti-clockwise 
to show the lux pot, sensitivity pot and 
the timing/lux Dip switches. Please adjust 
the Lux Level and Sensitivity potentiometer 
gently without force as this is a sensitive 
electronic part. After adjustment please 
wait 30 seconds for changes to take effect. 
It is recommend product is set up initially 
using the 10 secs walk test mode. 

Step 5

To set Auto Lux (150 Lux), switch Dip switch 4 
to the ON position. This will allow activation 
of the PIR from Dusk until Dawn only. 
To set manually then put dip switch 4 off 
and use the potentiometer to adjust to 
desired lux level setting. All the way to the 
plus setting will allow the PIR to switch 
day and night. All the way to the minus sets 
the timer to ZERO lux and effectively 
switches off the PIR. To set manually you 
will need to be present at dusk 
(See Diagram 3).

Step 6

To adjust sensitivity turn anti-clockwise 
to the High (H) setting to increase 
sensitivity and clockwise to the Low (L) to  
decrease sensitivity.

Step 7

To set time please utilise the dip switch 
timing diagram above. The black bar 
denotes dip switch position. Replace fascia 
ring by turning anti clockwise 
(See Diagram 4).

Continued overleaf...

3

INSTRUCTION GUIDE

 

|

 

CEILING MOUNT PIR TIMER – 3 WIRE

Содержание 374B-1

Страница 1: ...ff the load after the adjustable time period has elapsed If infra red heat is detected again during the timing period the timing sequence will restart The unit has a lux level adjustment and Auto Lux function which measures the ambient light levels and prevents lighting being switched on when there is sufficient lighting in the room There is sensitivity adjustment and test mode function added for ...

Страница 2: ...osition of the dip switch Dip switch 4 is only used for Setting Automatic 150 Lux or Manual Lux ONLY Diagram 2 Diagram 2 heating and ventilation They should not be placed within 1 metre of the load Sensors work when objects move across their field of view Position the sensor where people will be detected walking across the zones rather than towards the zones identified in Diagram 1 Adjust sensitiv...

Страница 3: ...tical position and insert unit into the hole Release unit ensuring arms are securely in place For surface mounting fit surface mount cup onto ceiling or conduit terminal box and return connected PIR into surface mount cup Step 4 Remove the fascia by turning anti clockwise to show the lux pot sensitivity pot and the timing lux Dip switches Please adjust the Lux Level and Sensitivity potentiometer g...

Страница 4: ...ximately 1 minute to initialise and will flash rapidly after the mains power is first applied to allow the sensor to learn its environment The load will be ON after 7 seconds initially then switch off after 1 minute if there is no detection in the zones Operation of the Unit In standard operation the PIR will now sense infra red heat when a person or source of heat passes through the detection zon...

Отзывы: