OVERVIEW

The 

"TW" 

model of the ELK-M1XRF Wireless RF Receiver (part # ELKM1XRFTW) allows an ELK-M1 and ELK-M1EZ8

Controls to accept Elk's complete line of Two-Way Wireless Sensors.  Refer to the list of available transmitters in this manual.

Including this new Elk Two-Way Receiver, Elk now produces three (3) different models of wireless receivers for the M1 Control.
One is for Elk sensors (M1XRFTW), one is for GE sensors (M1XRF2G), and one is for Honeywell sensors (M1XRF2H).
Regardless of the receiver model, they each attach directly to the M1 via the four (4) wire Keypad Data Bus.  And they enroll
and integrate in much the same way as a hardwired zone expander, with the exception that a single M1XRF can handle up
to 144 wireless Sensors/Zones.  The benefits of operating from the data bus are: 1) Receiver(s) do not have to be installed
adjacent to the control, rather they can be installed virtually anywhere in a building up to the maximum distance of the data
bus.  This provides optimum convenience and coverage.  2) Multiple receivers (up to 11 total) can be connected to a single
control, providing greater coverage as well as redundancy.  Utilizing multiple receivers it is possible to cover hundreds if not
thousands of square feet with a receiver placed in strategic locations.

A strong point of the Elk Receivers is that all transmitter serial numbers and setup information is stored in the control panel
rather than in the receiver(s).  There are two advantages of this: 1) Sensors need only be enrolled one time, yet they can
be received by any compatible format "redundant" receiver in the building.  This is especially great for coverage of portable
Keychain (FOB) Remotes. 2) Should a receiver ever become damaged or need replacement it will not be necessary to re-
enroll the transmitters.  Simply replace the receiver and perform a data bus enrollment of the receiver to the control panel.

IMPORTANT NOTE - THE BRAND OF TRANSMITTERS INSTALLED MUST BE MATCHED TO THE CORRECT RECEIVER.

Receiver brands can be mixed on a single M1 Control, allowing a mixture of transmitter brands.   While this is
great for takeover situations, extreme care must be taken to assure that each transmitter is within range of it's
respective receiver model.  In other words, the receiver/transmitters are physically and electronically different
and are only compatible within their own brands.

Содержание M1XRFTW

Страница 1: ...Box 100 3266 US Hwy 70 West Hildebran NC 28637 828 397 4200 828 397 4415 Fax http www elkproducts com IMPORTANT NOTE ELK M1G and M1EZ8 Controls require application firmware ver 5 2 8 or higher to be...

Страница 2: ...NS Operating Frequency 902 Mhz to 928 Mhz Transmission Duration active on time 50 ms Sensitivity 105 dbm Operating Temperature 0 to 120 degrees F Operating Voltage 12 Volts D C Current Draw 25mA Recei...

Страница 3: ...control providing greater coverage as well as redundancy Utilizing multiple receivers it is possible to cover hundreds if not thousands of square feet with a receiver placed in strategic locations A s...

Страница 4: ...provide valuable information as to the operation of the M1XRF STATUS Data Bus Status Multiple conditions exist for this LED OFF No Power to the M1XRF ON Solid Power is good but it is not yet enrolled...

Страница 5: ...nge and coverage redundancy multiple like branded M1XRF Wireless Receivers can be installed on the bus Redundant receivers can be assigned to any unused data bus address as long as it doesn t conflict...

Страница 6: ...e ELK key then press 9 or scroll up to display 9 Installation Programming Press the RIGHT arrow key to select this menu The Installer Program Code PIN must be entered to access this menu 2 Enter the I...

Страница 7: ...ower using only enough power to get a signal through thereby maximizing the battery life of the sensor Confidence of signal strength at the time of installation another unique feature of the Elk Two W...

Страница 8: ...hod mentioned beside each device ElkRP Remote Programming involves typing in the TXID serial number of the sensor along with selecting the particular attributes Single Button Panic Xmtr Ademco Part 58...

Страница 9: ...and HOLD on the button If the M1 Lrn Enroll function has ended or been aborted it may be necessary to restart from the beginning with Step 1 M1 Rapid Enroll Feature The M1 Rapid Enroll feature advance...

Страница 10: ...456789012345678901234567890121234 123456789012345678901234567890121234 123456789012345678901234567890121234 123456789012345678901234567890121234 2 Xmit Sel b Prgr Transmitter Opt r 1234567890123456789...

Страница 11: ...123456789012123 12345678901234567890123456789012123 12345678901234567890123456789012123 12345678901234567890123456789012123 12345678901234567890123456789012123 12345678901234567890123456789012123 1234...

Страница 12: ...2 Zn 17 32 Data Bus Addr 3 Zn 33 48 Starting Zn ID 49 Data Bus Addr 4 Zn 49 64 M1XRF Cells marked indicate a Reserved Address which can only be used for wireless zones Cells marked RRF indicate bus ad...

Страница 13: ...r 11 Zn 161 176 M1XRF Data Bus Addr 2 Zn 17 32 Data Bus Addr 3 Zn 33 48 Data Bus Addr 4 Zn 49 64 Data Bus Addr 5 Zn 65 80 Data Bus Addr 6 Zn 81 96 Data Bus Addr 7 Zn 97 112 Data Bus Addr 8 Zn 113 128...

Страница 14: ...13 128 Zones 129 144 Zones 145 160 Zones 161 176 Zones 177 192 Zones 193 208 Bus Addr x Bus Addr 2 Bus Addr 3 Bus Addr 4 Bus Addr 5 Bus Addr 6 Bus Addr 7 Bus Addr 8 Bus Addr 9 Bus Addr 10 M1XIN or Key...

Страница 15: ...Updates directory This is where RP looks for all update files 7 Click on the check box for Update If Reprogram or Rollback is displayed the firmware file is the same as OR older that what is in the c...

Страница 16: ...Page 16 M1XRFTW Installation Manual...

Отзывы: