background image

Page 14

M1XRFTW Installation Manual

Example A

All 208 Zones as Hardwired

Zones

1-16

Inputs on

Main Panel

Zones

17-32

M1XIN

Zones

33-48

Zones

49-64

Zones

65-80

Zones

81-96

Zones

97-112

Zones

113-128

Zones

129-144

Zones

145-160

Zones

161-176

Zones

177-192

Zones

193-208

Example B

16 Hardwired Zones

144 Wireless Zones

NO

M1XIN

Expanders

on these

addresses

Example C

48 Hardwired Zones

112 Wireless Zones

PLUS 2 Redundant Receivers

Bus

Addr x

Bus

Addr 2

M1XIN

Bus

Addr 3

M1XIN

Bus

Addr 4

M1XIN

Bus

Addr 5

M1XIN

Bus

Addr 6

M1XIN

Bus

Addr 7

M1XIN

Bus

Addr 8

M1XIN

Bus

Addr 9

M1XIN

Bus

Addr 10

M1XIN

Bus

Addr 11

M1XIN

Bus

Addr 12

M1XIN or

Keypad

Zones

Bus

Addr 13

Zones

1-16

Inputs on

Main Panel

Zones

17-32

Zones

33-48

Zones

49-64

Zones

65-80

Zones

81-96

Zones

97-112

Zones

113-128

Zones

129-144

Zones

145-160

Zones

161-176

Zones

177-192

Zones

193-208

Bus

Addr x

Bus

Addr 2

Bus

Addr 3

Bus

Addr 4

Bus

Addr 5

Bus

Addr 6

Bus

Addr 7

Bus

Addr 8

Bus

Addr 9

Bus

Addr 10

M1XIN or

Keypad

Zones

Bus

Addr 13

M1XRF

M1XIN or

Redundant

M1XRF  *

NO

M1XIN

Expanders

on these

addresses

Zones

1-16

Inputs on

Main Panel

Zones

17-32

Zones

33-48

Zones

49-64

Zones

65-80

Zones

81-96

Zones

97-112

Zones

113-128

Zones

129-144

Zones

145-160

Zones

161-176

Zones

177-192

Zones

193-208

Bus

Addr x

Bus

Addr 2

Bus

Addr 3

Bus

Addr 4

Bus

Addr 5

Bus

Addr 6

Bus

Addr 7

Bus

Addr 8

Bus

Addr 9

Bus

Addr 10

M1XIN or

Keypad

Zones

Bus

Addr 13

M1XRF

M1XIN

M1XIN

Bus

Addr 14

Bus

Addr 15

N/A

N/A

N/A

N/A

Ma
xim
um o
f 1

12 
Wirele

ss

 Zo
nes

< -------  Redundant M1XRF *

< -------  Redundant M1XRF *

Max

imum of 144

 Wire

les
s Zones

M1XIN or

Redundant

M1XRF  *

Bus

Addr 11

Bus

Addr 12

Bus

Addr 11

Bus

Addr 12

Bus

Addr 14

Bus

Addr 15

N/A

N/A

N/A

N/A

Bus

Addr 14

Bus

Addr 15

N/A

N/A

N/A

N/A

Appendix B - Examples of Zone Configurations

Содержание M1XRFTW

Страница 1: ...Box 100 3266 US Hwy 70 West Hildebran NC 28637 828 397 4200 828 397 4415 Fax http www elkproducts com IMPORTANT NOTE ELK M1G and M1EZ8 Controls require application firmware ver 5 2 8 or higher to be...

Страница 2: ...NS Operating Frequency 902 Mhz to 928 Mhz Transmission Duration active on time 50 ms Sensitivity 105 dbm Operating Temperature 0 to 120 degrees F Operating Voltage 12 Volts D C Current Draw 25mA Recei...

Страница 3: ...control providing greater coverage as well as redundancy Utilizing multiple receivers it is possible to cover hundreds if not thousands of square feet with a receiver placed in strategic locations A s...

Страница 4: ...provide valuable information as to the operation of the M1XRF STATUS Data Bus Status Multiple conditions exist for this LED OFF No Power to the M1XRF ON Solid Power is good but it is not yet enrolled...

Страница 5: ...nge and coverage redundancy multiple like branded M1XRF Wireless Receivers can be installed on the bus Redundant receivers can be assigned to any unused data bus address as long as it doesn t conflict...

Страница 6: ...e ELK key then press 9 or scroll up to display 9 Installation Programming Press the RIGHT arrow key to select this menu The Installer Program Code PIN must be entered to access this menu 2 Enter the I...

Страница 7: ...ower using only enough power to get a signal through thereby maximizing the battery life of the sensor Confidence of signal strength at the time of installation another unique feature of the Elk Two W...

Страница 8: ...hod mentioned beside each device ElkRP Remote Programming involves typing in the TXID serial number of the sensor along with selecting the particular attributes Single Button Panic Xmtr Ademco Part 58...

Страница 9: ...and HOLD on the button If the M1 Lrn Enroll function has ended or been aborted it may be necessary to restart from the beginning with Step 1 M1 Rapid Enroll Feature The M1 Rapid Enroll feature advance...

Страница 10: ...456789012345678901234567890121234 123456789012345678901234567890121234 123456789012345678901234567890121234 123456789012345678901234567890121234 2 Xmit Sel b Prgr Transmitter Opt r 1234567890123456789...

Страница 11: ...123456789012123 12345678901234567890123456789012123 12345678901234567890123456789012123 12345678901234567890123456789012123 12345678901234567890123456789012123 12345678901234567890123456789012123 1234...

Страница 12: ...2 Zn 17 32 Data Bus Addr 3 Zn 33 48 Starting Zn ID 49 Data Bus Addr 4 Zn 49 64 M1XRF Cells marked indicate a Reserved Address which can only be used for wireless zones Cells marked RRF indicate bus ad...

Страница 13: ...r 11 Zn 161 176 M1XRF Data Bus Addr 2 Zn 17 32 Data Bus Addr 3 Zn 33 48 Data Bus Addr 4 Zn 49 64 Data Bus Addr 5 Zn 65 80 Data Bus Addr 6 Zn 81 96 Data Bus Addr 7 Zn 97 112 Data Bus Addr 8 Zn 113 128...

Страница 14: ...13 128 Zones 129 144 Zones 145 160 Zones 161 176 Zones 177 192 Zones 193 208 Bus Addr x Bus Addr 2 Bus Addr 3 Bus Addr 4 Bus Addr 5 Bus Addr 6 Bus Addr 7 Bus Addr 8 Bus Addr 9 Bus Addr 10 M1XIN or Key...

Страница 15: ...Updates directory This is where RP looks for all update files 7 Click on the check box for Update If Reprogram or Rollback is displayed the firmware file is the same as OR older that what is in the c...

Страница 16: ...Page 16 M1XRFTW Installation Manual...

Отзывы: