COPY CARD / UNICARD
When connected to the serial port (TTL), the Copy Card/Unicard allows instrument parameters to be programmed rapidly.
Enter PA2 to access “Installer” parameters, scroll through the folders using
and
until folder
FPr
is displayed.
Press
to select it, scroll through the parameters using
and
then press
(e.g. UL) to select the function.
•
Upload
(UL):
select UL and press
. This function uploads the programming parameters from the instrument to the card.
If the operation is successful, the display will show “
y
”, otherwise it will show “
n
”.
•
Format
(Fr):
This command is used to format the copy card (which is necessary when using the card for the first time).
Important
: the Fr parameter deletes all data present. This operation cannot be reversed.
•
Download
(dL): Connect the Copy Card when the instrument is switched off. At power-on, data will automatically start
downloading from the USB key to the instrument. At the end of the lamp test, the display will show “
dLy
”
if the operation was successful and “
dLn
” if not.
NOTE
: After the download, the instrument will use the newly uploaded map settings.
ELECTRICAL CONNECTIONS
Important! Make sure the machine is switched off before working on the electrical connections.
The instrument is equipped with screw connectors to connect power cables with a maximum cross-section of 2.5mm
2
(one wire per
terminal). Make sure that the power supply is of the correct voltage for the device.
Temperature probes
(NTC, PTC, PT1000) have no connection polarity and can be extended using a normal bipolar cable (note that
the extension of the probes influences the instrument's EMC electromagnetic compatibility: take great care with the wiring).
Ratiometric
or
pressure probes
(4...20mA), have a connection polarity.
Probe cables, power supply cables and the RS485 serial cable should be routed separately from power cables.
DISCLAIMER
This document is the exclusive property of ELIWELL CONTROLS SRL and may not be reproduced or circulated without the express
permission of ELIWELL CONTROLS. While all possible care has been taken to ensure the accuracy of this document, ELIWELL
CONTROLS SRL cannot accept liability for any damage resulting from its use. The same applies to any person or company involved
in preparing and editing this document. ELIWELL CONTROLS SRL reserves the right to make aesthetic or functional changes at any
time without notice.
LIABILITY AND RESIDUAL RISKS
ELIWELL CONTROLS SRL declines all liability for damage due to:
- installation/use other than expressly specified and, in particular, in conflict with the safety prescriptions set down in regulations
and/or specified in this document;
- use on panels that do not provide adequate protection against electric shocks, water or dust in the adopted mounting conditions;
- use on panels allowing access to dangerous parts without having to use tools;
- tampering with and/or modification of the product;
- installation/use on panels that do not comply with statutory laws and regulations.
CONDITIONS OF USE
Permitted use
For safety reasons, the device must be installed and used according to the instructions provided. In particular, parts carrying dan-
gerous voltages must not be accessible in normal conditions. The device must be adequately protected from water and dust with
regard to the application, and must only be accessible using tools (with the exception of the front panel). The device is suitable for
use in household refrigeration appliances and/or similar equipment and has been tested for safety aspects in accordance with the
harmonized European reference standards.
Improper use
Any use other than that expressly permitted is prohibited. The relays provided are of a functional type and can be subject to failure:
any protection devices required by product standards, or suggested by common sense for obvious safety requirements, must be
installed externally to the controller.