background image

code 9IS54225-1 - Televis

In

&

Out

 - rel.05/12 - EN -

© Eliwell Controls s.r.l. 2012 - All rights reserved.

Eliwell Controls s.r.l.

 

Via dell’Industria, 15 • Z.I. Paludi
32010 Pieve d’Alpago (BL) - ITALY
Telephone:  +39 0437 986 111
Fax: 

+39 0437 989 066

www.eliwell.com

Technical Customer Support:

Technical helpline: +39 0437 986 300
E-mail: [email protected]

Sales:

Telephone:  +39 0437 986 100 (Italy)
 

+39 0437 986 200 (other countries)

E-mail: [email protected]

COPY CARD / UNICARD

When connected to the serial port (TTL), the Copy Card/Unicard allows instrument parameters to be programmed rapidly. 
Enter PA2 to access  “Installer” parameters, scroll through the folders using 

 and 

until folder 

FPr

 is displayed.

Press 

 to select it, scroll through the parameters using 

 and 

 then press  

 (e.g. UL) to select the function.

 

• 

Upload

 (UL): 

 select UL and press 

. This function uploads the programming parameters from the instrument to the card. 

If the operation is successful, the display will show “

y

”, otherwise it will show “

n

”.

 

• 

Format

 (Fr): 

This command is used to format the copy card (which is necessary when using the card for the first time).

     

Important

: the Fr parameter deletes all data present. This operation cannot be reversed.

 

• 

Download

 (dL):   Connect the Copy Card when the instrument is switched off. At power-on, data will automatically start 

downloading from the USB key to the instrument. At the end of the lamp test, the display will show “

dLy

” 

if the operation was successful and “

dLn

” if not.

NOTE

: After the download, the instrument will use the newly uploaded map settings.

ELECTRICAL CONNECTIONS

Important! Make sure the machine is switched off before working on the electrical connections.

The instrument is equipped with screw connectors to connect power cables with a maximum cross-section of 2.5mm

2

 (one wire per 

terminal). Make sure that the power supply is of the correct voltage for the device.

Temperature probes

 (NTC, PTC, PT1000) have no connection polarity and can be extended using a normal bipolar cable (note that 

the extension of the probes influences the instrument's EMC electromagnetic compatibility: take great care with the wiring).

Ratiometric

 or 

pressure probes 

(4...20mA), have a connection polarity.

Probe cables, power supply cables and the RS485 serial cable should be routed separately from power cables.

DISCLAIMER

This document is the exclusive property of ELIWELL CONTROLS SRL and may not be reproduced or circulated without the express 

permission of ELIWELL CONTROLS. While all possible care has been taken to ensure the accuracy of this document, ELIWELL 

CONTROLS SRL cannot accept liability for any damage resulting from its use. The same applies to any person or company involved 

in preparing and editing this document. ELIWELL CONTROLS SRL reserves the right to make aesthetic or functional changes at any 

time without notice.

LIABILITY AND RESIDUAL RISKS

ELIWELL CONTROLS SRL declines all liability for damage due to:

  -  installation/use other than expressly specified and, in particular, in conflict with the safety prescriptions set down in regulations 

and/or specified in this document;

  -  use on panels that do not provide adequate protection against electric shocks, water or dust in the adopted mounting conditions;

  - use on panels allowing access to dangerous parts without having to use tools;

  - tampering with and/or modification of the product;

  - installation/use on panels that do not comply with statutory laws and regulations.

CONDITIONS OF USE

Permitted use

For safety reasons, the device must be installed and used according to the instructions provided. In particular, parts carrying dan-

gerous voltages must not be accessible in normal conditions. The device must be adequately protected from water and dust with 

regard to the application, and must only be accessible using tools (with the exception of the front panel). The device is suitable for 

use in household refrigeration appliances and/or similar equipment and has been tested for safety aspects in accordance with the 

harmonized European reference standards.

Improper use

Any use other than that expressly permitted is prohibited. The relays provided are of a functional type and can be subject to failure: 

any protection devices required by product standards, or suggested by common sense for obvious safety requirements, must be 

installed externally to the controller.

Отзывы: