27
Short duration (Less than one month)
Allow the unit to run in no load condition for some time, then close the unit and
keep it under shelter, free from dust and moisture.
Long duration (More than one month)
Remove the air filter and pour 50ml preservation oil (Servo press 150) through
suction port of each LP cylinder. Remove the suction pipe of H.P cylinder,
pour rust prevention oil for the HP cylinder and then allow the unit for a few
minutes. Drain oil from the crankcase.
Now assemble the suction pipe and air filter, cover the whole unit. Keep the
unit under shelter. The unit should be thoroughly cleaned and examined every
month for corrosion prevention and free rotation.
Preservation