3
2
1
Fig. 5 Circuit diagram SunTop-915 120 V / 60 Hz and
Wiring when using a Hirschmann plug connection
STAS-3 (with bridge)
5.4 Parallel
connection
Important
You can connect several SunTop-915 systems in parallel.
To do so, please observe the maximum control capacity.
5.5 Commissioning
Important
On delivery, the drive system is set to commissioning mode.
►
It is necessary to set the end positions with the
elero
installation cable (refer to
fi
g. 6) or a
elero
wand/hand
transmitter (refer to
fi
g. 7).
►
Connecting the installation cable is only for commissio-
ning of the drive system and for con
fi
guration.
5.5.1 Installation cable connection
Blau (Neutralleiter)
(1)
Schwarz
(2)
Braun
(3)
Grün-gelb
ele
ro
Blue (neutral wire) (1)
Black (2)
Brown (3)
Green-yellow (4)
Fig. 6 Installation cable connection
►
Switch on power supply.
►
Now, you can set the end positions with the
elero
instal-
lation cable.
5.5.2 Wireless connection (transmitter operation)
ele
ro
Blue (neutral wire) (1)
Black (2)
Brown (3)
Green-yellow (4)
Fig. 7 Wireless connection (transmitter operation)
►
Switch on power supply.
►
The drive system moves up and down brie
fl
y.
Now, the drive system is in wireless operation.
Now, you can program the transmitter(s).
5.6
End position and relief settings
Setting of end positions and relief can either be carried out
• by means of
elero
installation cable (ensure proper con-
nection according to section 5.5.1) or
• by means of a programmed transmitter.
Programming a transmitter for a drive system is descri-
bed in section 5.7.
6 | US+CA
©
elero
GmbH
Installation: Electrical connection
5.2 Electrical
connection
WARNING
Danger to life due to incorrect electrical connection.
Risk of electric shock.
►
Before initial commissioning, check the correct connec-
tion of the PE conductor.
NOTE
Damage to the SunTop-915 due to incorrect electrical con-
nection.
►
Before initial commissioning, check the correct connec-
tion of the PE conductor.
Damage to or destruction of the SunTop-915 due to ingress
of humidity.
►
For devices with protection class IP44, the customer-
provided connection of cables or plugs (wiring) must also
be compliant with protection class IP44.
Damage to or destruction of the SunTop-915 for models
with 230 V 1 AC due to incorrect control.
►
Switches that are preset to OFF (dead man) for drive
systems must be mounted in viewing range of the Sun-
Top-915 but away from moving parts and at a height
above 1.5 m.
Important
For electrical connection, generally no connection and dis-
connection of the connection cable or plug is necessary.
Only connect when the system is disconnected from
the voltage. To do so, disconnect the drive cable.
1 Use a suitable screwdriver to push the locking mecha-
nism of the device plug to the cable.
2 Disconnect the plug.
3 Insert the device plug until the locking mechanism enga-
ges.
Removing and inserting the device plug
Delivery con-
dition
Remove plug
Insert plug
Fig. 4 Removing and inserting the device plug
5.3
Connection example SunTop-915 120 V / 60 Hz
N
PE
L1
sw
br
bl
gr
/g
e
→
1
→
2
→
3
1
Winding thermostat
2
Device plug
3
Junction box
(outside of roller shutter case)
4
Electronic
5
Condenser
sw
black
br
brown
bl
blue
gr/ge
green/yellow