24
5
Teach-in of the limit positions of the actuators
Module
Handling
Result
1. Adjustment of speed:
•
rotate right = faster
•
rotate left = slower
Optimum value: maximum speed
2. Adjustment of cut-out force:
•
step 0 = low force
•
step 9 = high force
Only select a step as high as necessary!
3. Switch the power
supply to ON.
•
LED-1
fl
ashes green on the control unit.
4. Close the pergola completely.
5. Run 3 complete paths
all to the limit position.
NOTE
If the green LED is still
fl
ashing after
three movements, run another one.
•
LED-1 lights green on the control unit.
•
LED-2 does not light red on the control unit.
6. Check intermediate position 1:
Press the DOWN key brie
fl
y twice
in succession.
•
Pergola stops at INT-1 (default 33% open).