Explanation of functions
10 | EN
Semi-automatic mode
The system is in AUTO mode.
The system switches to semi-automatic mode, as soon as you
press a button on your AeroTec.
The automatic sun protection is disabled in semi-automatic
mode. No automatic motion is triggered from the
undershoot/overshoot of the light threshold value.
The system stays in the position it has been driven too and the
set points and reached values are shown on the display.
The wind monitor remains active.
Leave semi-automatic mode:
Set the sliding switch on the Aero Tec briefly to MANUAL mode
and then to AUTO mode again.
The system retracts automatically.
or
Press the
UP
button.
Approach the upper limit stop.
The drive switches off automatically when the upper limit position
is reached.
or
The system retracts automatically, once the lowest light value
(step 1) is undershot.
or
The system is retracted with a “wind“ command.
Afterwards the system is in AUTO mode again.
Manual/ Automatic sliding switch
In the “
MANUAL
“ mode, only manual control commands and
alarm signals are executed.
When the sliding switch is set to “
AUTO
“, automatic control
commands are carried out (e.g. wind alarm, ...)
Alarm signal control light
If the alarm signal control light is illuminated, this indicates an
alarm signal. An alarm signal is a continuous switching signal at
the group control inputs which lasts for more than 5 seconds.
Group control
Group control refers to the simultaneous control of several drives.
Operating mode
The current wind and/or sunlight settings can be seen in the dis-
play.
OK button
Press the
OK
button to store the current values displayed.
To activate the test mode, press the
OK
button and hold for
5 seconds. In addition, the MANUAL/AUTO sliding switch must be
set to
AUTO
.
EN | 11