INSTALLATION GUIDE FOR EUREKA CISTERN TANK
Plycem guarantees that in case it is proven that a product with its
brand is defective regarding its materials or manufacturing pro-
cess within 100 years (5 years for accessories) as of its manufac-
turing date, at the discretion of the company, fix or replace the said
product. Plycem’s responsibility is exclusively limited to the cost of
the product, and it excludes the cost for installing or removing the
product or for any resulting damage.
Neither Plycem nor its distributors authorized in Central America
shall be responsible for any indirect damages or defects caused by
the incorrect installation or by the omission of any steps described
in this document. It does not cover transportation or labor costs
that may result from the incorrect application of the installation
procedures indicated. The manufacturer’s warranty only covers
manufacturing defects.
Using an Eureka Tank Product for a purpose different from any pur
-
pose described in this document is not recommended. Any other
use will void the warranty for the Eureka Tank by Plycem -either ex-
press or implied. In no case, Plycem may be deemed responsible
for the resulting damages.
This limited standard warranty does not apply to damages result-
ing from the incorrect use of the product, the incorrect application
of the recommended materials, accidents, installation, omission of
procedures, or from inadequate maintenance.
Warranty
Installation precaution
General installation
1.
Remove the discharge plug from
the multi-connector, remove all
contents and rinse.
2.
3.
Do a final cleaning of the inside
walls and bottom with a clean, dry
rag or mop.
4.
5.
Install the discharge plug on the
manifold and open the valve that
supplies water to your home.
6.
7.
Turn on the water supply to your
Cistern, wait for it to fill and it is
ready to use.
5
6
7
8
•
Cisterns should be washed before installation.
•
The tank should always be cleaned every six months. Check
the filter and connections and make necessary adjustments
and repairs.
•
The Cistern should always be covered.
•
When using a pumping system, the inlet pipe should be
anchored to cushion any movement on the Cistern connector.
•
The system should be installed in an easily accessible location
to allow for inspection and to facilitate proper maintenance.
•
When storing the Cistern before installation, be sure to keep it
in an upright position on a smooth, level surface.
•
The temperature of the liquid to be stored must not exceed 60°
Celsius.
•
For the installation of additional accessories to the Cistern, it is
important to consult your authorized supplier beforehand.
•
Cistern tanks are not fire resistant. Do not store them near a
flame or heat exceeding 80° Celsius.
•
Make sure the level of the support surface of the tank.
•
Make sure that the support surface is larger than the bottom
of the tank.
•
Do not place the tank on irregular ground.
•
Do not place the tank on separate parts or beams.
•
Do not place the tank on irregular surfaces, vegetation, roots
or elements that may damage the bottom of the tank.
1.
Shut off the water supply to the
Cistern.
2.
Empty your cistern until there
is about 5 cm of water at the
bottom.
3.
Shut off the water supply to your
house by closing the valve.
4.
Wash the inside walls and the
bottom of your Cistern with
a plastic bristle brush and
disinfectant liquid soap.
1
2
3
4
Maintenance
5.
6.
7.
8.