Страница 2: ...INSTALLATION MANUAL i Do not use this product as a primary heat source...

Страница 3: ...8 6 1 FIRE SAFETY DEVICE SET UP 8 6 1 1 PROTECTION OF WALL AND CEILING 8 6 2 ASSEMBLY REGULATIONS 8 6 2 1 GENERAL ASSEMBLY REGULATIONS 8 6 2 2 ASSEMBLY REGULATIONS FOR NON FLAMMABLE MATERIALS 8 6 2 3...

Страница 4: ...SOUND CHECK 19 A TROUBLESHOOTER 20 A A FIRST AID FOR MALFUNCTION 20 A B NECESSARY TOOLS 24 B ERRORS CODES PROCONTROL APP 25 B A MESSAGES SHOWN IN APP 25 B B MESSAGES SHOWN IN REMOTE 26 C FAULTS AND E...

Страница 5: ...unted to the device Make sure it is accessible at all times This device may not be used a primary heat source This device is designed to be used with natural gas or LPG The device can only be used wit...

Страница 6: ...sembly error or material defect Element4 will provide a free replacement part to the installer without compensation for disassembly or montage 5 In case the installer is not able to fix the problem hi...

Страница 7: ...ON 1 2 OFF Figure 3 1 Remote and ignition sign Figure 3 2 Gas Block Figure 3 3 Top and side view of the Receiver 4 2 IGNITING THE PILOT LIGHT Check that the control knob A is in the ON position Figur...

Страница 8: ...e in the near vicinity of the device Position the gas connection such that it is always accessible for service purposes The gas block and receiver are under the combustion chamber in the deivce so tha...

Страница 9: ...objects e g built in furniture or wooden panels are mountedonthesideofthewallthatisturnedawayfromthefireplace For these types of installations please refer to CHAPTER 6 2 3 CHAPTER 6 2 3 6 2 ASSEMBLY...

Страница 10: ...fireplace 200 C Table 6 1 Legenda 6 7 21 6 6 7 21 6 E d3 D F G I d1 H A2 B C d2 Figure 6 4 C31 Flue situation Flammable materials 6 7 21 6 RQ 5 1 339 0 4 81 66 27 5 6 63 0 16 216 5 1 0 0 7 56 685 1 6...

Страница 11: ...enclosure ventilation opening are necessary Figure 6 5 The ventilation grills are to be placed at a minimal distance of 20cm from the ceiling and 30cm from any built in furniture from the side any fla...

Страница 12: ...nal see APPENDIX E APPENDIX E you search for the corresponding calculation tables Each category refers to a set of tables 1 A table for horizontal outlet 2 A table for vertical outlet 3 A table for re...

Страница 13: ...FLUE MATERIAL Follow the following instrucions for the installation of flue materials Drill a hole of 160 mm for the wall or roof transit with a 150 mm diameter flue connection and 210 mm with a flue...

Страница 14: ...one week to ensure yourself of an optimal desired room temperature Also the device can changed between high and low flames and it features an eco setting The amount of users that can operate the devic...

Страница 15: ...ection The trays can be easily removed for maintenance The trays must be filled with the supplied glass crystals Divide the glass evenly over the bottom so that the light is well broken Cover the glas...

Страница 16: ...r the trims are removed in as in step 10 1 1 Remove the ropes holding the glass See Figure 9 3 Put the section cup on the glass and make sure it is properly vaccuumed so it will not come off See Figur...

Страница 17: ...15 Chapter 9 INSTALLATION MANUAL Figure 9 2 Remove side trims Figure 9 3 Put on suction cup Figure 9 4 Remove Glass ropes Figure 9 5 Remove Windows...

Страница 18: ...this is the case check the burner pressure at the inlet to the burner The instructions of changing the burner pressure and the correct pressure per gastype can be found in 9 3 2 PILOT The pilot flame...

Страница 19: ...ltering system is used Re fit the firebed arrangement reseal the appliance and check the safe operation of the appliance 10 DECORATIVE CERAMIC PARTS This appliance is equipped with a ceramic fire bed...

Страница 20: ...ble plus button to switch between burners Flames and soot During this first fire examine the flame for appearance and quality Flames may appear blue at first but will turn yellow after 15 to 20 minute...

Страница 21: ...turbs the reception Change the position of the antenna See Figure A B C No ignition no beep 1 Receiver defective Reset the receiver See K1 If necessary replace the receiver D No ignition receiver give...

Страница 22: ...Appendix A INSTALLATION MANUAL Figure A A Bend pin Figure A B Antenna Figure A C Torx screw Figure A D Testpoint 4 5 mV 4 5 mV Figure A E Interrupter Figure A F Wiring receiver 40mm Figure A G Pilot s...

Страница 23: ...ouple Position burner grate 3 Airflow in the burner chamber causes a restless fire image Check drain configuration Fit a flue gas limiter I Receiver gives 3 short beeps after each command 1 Batteries...

Страница 24: ...Aux position receiver AM PM ON 1 2 OFF Figure A L Double plus button on the remote Figure A M SI port PANEL G60 ZCE 1000 MA GR MO SW 2 1 3 MODE Ignition Main Burner High Flames Pilot Extinguish Main...

Страница 25: ...ed Please note If a problem is found that cannot be solved on site always contact your dealer or directly contact Element4 via our credentials which can be found on the back page of this manual 00 00...

Страница 26: ...eeps for 3 sec during motor turn Low Receiver battery power supply F10 Contact Service Pilot lit Main burner fails to ignite and pilot shuts off Ignition is blocked for 2 minutes 2nd thermocouple is o...

Страница 27: ...mmunication between Receiver and myfire Wi Fi Box F44 Contact Service No temperature shown in App N a not applicable displayed in App Handset not within range Low battery power in handset F49 Contact...

Страница 28: ...istances from occurring Many people put the router in the meter cupboard because that is where the internet comes in at many households A bad choice For a powerful WiFi signal the router needs as much...

Страница 29: ...NAL LOCATION WITH VERTICAL EXHAUST C11 Distance Exhaust 1 2 of 3 At the same roof level 6m At a different roof level 3m On a lower wall 2m On a higher sloping surface 6m Distance minimum distance requ...

Страница 30: ...V 4 O O O O O V V V V 3 5 O O O O O V V V V 3 V V V V V V V V V 2 5 V V V V V V V V X 2 V V V V V V V X X 1 5 V V V V V V X X X 1 V V V V V X X X X 0 0 5 1 2 2 5 3 5 4 4 5 5 Total Horizontal Section T...

Страница 31: ...n 2x 280 log 1x 80 Main 2x 120 log Type of flue C11 C31 C91 Additional electricity use At rated heat output elmax 9 5 kW With minimal heat emission elmin 9 5 kW In standby mode elsb 9 5 kW Power requi...

Страница 32: ...always supplied with the fireplace The ecolabel shows which category the fireplace belongs to G A ECOLABELS The ecolabels for the different types of gas are indicated below respectively G20 G25 and G3...

Страница 33: ...nd the dimensional drawings of the Fireplace with some of the important dimensions that you have to take into account when installing and installing your fireplace 199 703 165 427 170 420 714 119 280...

Страница 34: ...33 Appendix H INSTALLATION MANUAL 200 703 170 165 420 427 747 234 420 714 119 280 338 688 741 739 749 48 326 Figure H B Dimensional drawing of the Summum 70 C...

Страница 35: ...34 Appendix H INSTALLATION MANUAL 200 703 780 170 165 420 427 420 234 714 119 280 806 47 338 780 688 800 326 Figure H C Dimensional drawing of the Summum 70 3S...

Страница 36: ...Info element4 nl www element4 nl 03 02 22 ELEMENT 4 B V Design Assembly by RELEASE DATE...