2 8
Appendix E
I N S T A L L A T I O N M A N U A L |
E
CALCULATION TABLES FLUEGAS RESTRICTION
In the calcualtion table yo ucan see when you need to place a flue gas
restrictor
The Modore 185, Modore 240 & Tenore 240 need a minimum start
length of 1 meter.
The Modore 240H, Bidore 240H, Lucius 240H & Tenore 240H need a
minimum start length of 2 meter
Result
Action
V
No restrictor needed
O
Place the restrictor
X
No good operation guaranteed*
E�A
HORIZONTAL TERMINAL FLUE DIAMETER 200/130
E�B
VERTICAL TERMINAL FLUE DIAMETER 200/130
Total v
ertical Section
10
O
O
O
V
V
V
V
9
O
O
O
O
O
V
V
8
O
O
O
O
O
V
V
7
O
O
O
O
O
V
V
6
O
O
O
O
O
V
V
5
O
O
O
O
O
V
X
4
O
O
O
O
V
X
X
3
V
V
V
V
X
X
X
2.5
V
V
V
V
X
X
X
2
V
V
V
X
X
X
X
1.5*
V
V
X
X
X
X
X
1*
V
V
X
X
X
X
X
0
0.5
1
1.5
2
2.5
3
Total Horizontal Section
Total v
ertical Section
23
V
X
X
X
X
X
X
22
V
V
V
X
X
X
X
21
O
O
V
V
V
X
X
20
O
O
O
O
0
V
V
19
O
O
O
O
O
O
V
18
O
O
O
O
O
O
V
17
O
O
O
O
O
O
V
16
O
O
O
O
O
O
V
15
O
O
O
O
O
O
V
14
O
O
O
O
O
O
V
13
O
O
O
O
O
O
V
12
O
O
O
O
O
O
V
11
O
O
O
O
O
O
V
10
O
O
O
O
O
O
V
9
O
O
O
O
O
O
V
8
O
O
O
O
O
V
V
7
O
O
O
O
O
V
V
6
O
O
O
O
O
V
V
5
O
O
O
O
O
V
X
4
O
O
O
O
V
X
X
3
V
V
V
V
X
X
X
2.5
V
V
V
V
X
X
X
2
V
V
V
X
X
X
X
1.5*
V
V
X
X
X
X
X
1*
V
V
X
X
X
X
X
0
0.5
1
1.5
2
2.5
3
Total Horizontal Section
* Attention:
Does not apply to the Modore 240H, Bidore 240H, Lucius
240H and Tenore 240H
* Perhaps the powerfan is a good solution here.
Attention:
It is never allowed to reduce the flue diameter for this
fireplace
Attention:
For information on how to calcualte bends see
CHAPTER 7
CHAPTER 7