background image

4

Chapter 1 

I N S T A L L A T I O N   M A N U A L   |

4

CE STATEMENT 

We hereby declare that the design and construction of the Element4 gas 
appliances are complying to the essential demands and regulations for 
gas products. 

Product: 

• 

Gas fireplace, local spaceheater 

Model: 

E4-14

• 

Modore 240

• 

Tenore 240

Applicable EG-guidelines: 

• 

(EU) 2016/426 (GAR)

Applicable harmonized norms: 

• 

NEN-EN-613

• 

NEN-EN-613/A1

This declaration loses its validity when changes to the device are made 
without the written permission by Element4. You can ask for a copy of 

the test certificates of all models via our general e-mail adress, which is 

found on the back of this manual. 

J. Kempers

CEO

IMPORTANT SAFETY INFORMATION

Please take into account the following things for a safe installation of 

your fireplace! 

• 

The fireplace may only be installed by a qualified installer/dealer, 

following these installation instructions. We advise you to read 

these instructions properly, before commencing the installation of 

your device. 

• 

Before installation check the decive for transport damage and 
inform your supplier immediatly if damage is found. 

• 

Check the data on the data plate. The gas type and pressure should 
check out with those locally available. The data plate is mounted to 
the device. Make sure it is accessible at all times.  

• 

This device may not be used a primary heat source! 

• 

This device is designed to be used with natural gas or LPG. The 

device can only be used with the type of gas specified on the data 

plate at the time of purchase. 

• 

The device may never be used when glass is broken or damaged. 

The flue gasses can get into the installation room. The settings and 
construction of the device must not be changed! 

• 

Parts are only to be changed with original parts by the original 
manufacturer. 

• 

The device is provided with a special set of decorative materials. 
Do not place any extra imitation logs or decoration material on the 
burner or in the combustion chamber. See "

CHAPTER 10

CHAPTER 10

" for an 

instruction on how to arrange the decoration properly. 

• 

The glass and frame on this appliance acts as a fireguard conforming 
to BS: 1945 – 1971 and satisfies the Heating Appliance (Fireguards) 

regulations 1991. 

• 

No part of the window or frame should be permanently removed. 

It does not give protection for young children aged or infirm, extra 

guarding (conforming to BS8423: 2002) should be considered so 
the special hazards that exist in nurseries and other places where 

there are young children, aged or infirm persons are minimized.

• 

The heat that is coming from the device may effect the materials 

in its surroundings. Always take into account to correct safety 

distances. For more information see "

CHAPTER 6

CHAPTER 6

"

Содержание Modore 240

Страница 1: ...INSTALLATI O N MA NUAL INSTALLATI O N MA NUAL Please leave these instructions behind with the device M O D O R E A N D T E N O R E 2 4 0...

Страница 2: ...INSTALLATION MANUAL i Do not use this product as a primary heat source...

Страница 3: ...ION 8 6 1 FIRE SAFETY DEVICE SET UP 8 6 1 1 PROTECTION OF WALL AND CEILING 8 6 2 ASSEMBLY REGULATIONS 8 6 2 1 GENERAL ASSEMBLY REGULATIONS 8 6 2 2 ASSEMBLY REGULATIONS FOR NON FLAMMABLE MATERIALS 8 6...

Страница 4: ...18 A TROUBLESHOOTER 19 A A FIRST AID FOR MALFUNCTION 19 A B NECESSARY TOOLS 23 B ERRORS CODES PROCONTROL APP 24 B A MESSAGES SHOWN IN APP 24 B B MESSAGES SHOWN IN REMOTE 25 C FAULTS AND ERROR CODES IN...

Страница 5: ...evice Make sure it is accessible at all times This device may not be used a primary heat source This device is designed to be used with natural gas or LPG The device can only be used with the type of...

Страница 6: ...sembly error or material defect Element4 will provide a free replacement part to the installer without compensation for disassembly or montage 5 In case the installer is not able to fix the problem hi...

Страница 7: ...ON 1 2 OFF Figure 3 1 Remote and ignition sign Figure 3 2 Gas Block Figure 3 3 Top and side view of the Receiver 4 2 IGNITING THE PILOT LIGHT Check that the control knob A is in the ON position Figur...

Страница 8: ...e in the near vicinity of the device Position the gas connection such that it is always accessible for service purposes The gas block and receiver are under the combustion chamber in the deivce so tha...

Страница 9: ...objects e g built in furniture or wooden panels are mountedonthesideofthewallthatisturnedawayfromthefireplace For these types of installations please refer to CHAPTER 6 2 3 CHAPTER 6 2 3 6 2 ASSEMBLY...

Страница 10: ...fireplace 200 C Table 6 1 Legenda 6 7 21 6 6 7 21 6 E d3 D F G I d1 H A2 B C d2 Figure 6 4 C31 Flue situation Flammable materials 6 7 21 6 RQ 5 1 339 0 4 81 66 27 5 6 63 0 16 216 5 1 0 0 7 56 685 1 6...

Страница 11: ...enclosure ventilation opening are necessary Figure 6 5 The ventilation grills are to be placed at a minimal distance of 20cm from the ceiling and 30cm from any built in furniture from the side any fla...

Страница 12: ...radation 7 2 2 REFERENCE THE FLUE CALCULATION In order to ascertain whether your intended extraction shall function properly a stove category is determined After you have determined the applicable cat...

Страница 13: ...AL Follow the following instrucions for the installation of flue materials Drill a hole of 160 mm for the wall or roof transit with a 150 mm diameter flue connection and 210 mm with a flue with a diam...

Страница 14: ...is to pre set the temperature of you device for a period of one week to ensure yourself of an optimal desired room temperature Also the device can changed between high and low flames and it features a...

Страница 15: ...urners and pilot for good condition and operation 10 Replace Grate 11 Replace the Firebed arrangements 12 Replace the access doors 13 Check the flue system and terminal making sure that the terminal v...

Страница 16: ...15 Chapter 9 INSTALLATION MANUAL Figure 9 2 Remove side trims Figure 9 3 Remove bottom trim Figure 9 4 Remove glass cords Figure 9 5 Put on suction cup Figure 9 6 Remove side glasses...

Страница 17: ...this is the case check the burner pressure at the inlet to the burner The instructions of changing the burner pressure and the correct pressure per gastype can be found in 9 2 2 PILOT The pilot flame...

Страница 18: ...t problems Not doing so may cause the fire to explode on ignition 10 DECORATIVE CERAMIC PARTS This appliance is equipped with a ceramic fire bed with heat resistant ceramic fibers or artificial glassy...

Страница 19: ...ble plus button to switch between burners Flames and soot During this first fire examine the flame for appearance and quality Flames may appear blue at first but will turn yellow after 15 to 20 minute...

Страница 20: ...turbs the reception Change the position of the antenna See Figure A B C No ignition no beep 1 Receiver defective Reset the receiver See K1 If necessary replace the receiver D No ignition receiver give...

Страница 21: ...Appendix A INSTALLATION MANUAL Figure A A Bend pin Figure A B Antenna Figure A C Torx screw Figure A D Testpoint 4 5 mV 4 5 mV Figure A E Interrupter Figure A F Wiring receiver 40mm Figure A G Pilot s...

Страница 22: ...ouple Position burner grate 3 Airflow in the burner chamber causes a restless fire image Check drain configuration Fit a flue gas limiter I Receiver gives 3 short beeps after each command 1 Batteries...

Страница 23: ...Aux position receiver AM PM ON 1 2 OFF Figure A L Double plus button on the remote Figure A M SI port PANEL G60 ZCE 1000 MA GR MO SW 2 1 3 MODE Ignition Main Burner High Flames Pilot Extinguish Main...

Страница 24: ...ed Please note If a problem is found that cannot be solved on site always contact your dealer or directly contact Element4 via our credentials which can be found on the back page of this manual 00 00...

Страница 25: ...eeps for 3 sec during motor turn Low Receiver battery power supply F10 Contact Service Pilot lit Main burner fails to ignite and pilot shuts off Ignition is blocked for 2 minutes 2nd thermocouple is o...

Страница 26: ...mmunication between Receiver and myfire Wi Fi Box F44 Contact Service No temperature shown in App N a not applicable displayed in App Handset not within range Low battery power in handset F49 Contact...

Страница 27: ...istances from occurring Many people put the router in the meter cupboard because that is where the internet comes in at many households A bad choice For a powerful WiFi signal the router needs as much...

Страница 28: ...NAL LOCATION WITH VERTICAL EXHAUST C11 Distance Exhaust 1 2 of 3 At the same roof level 6m At a different roof level 3m On a lower wall 2m On a higher sloping surface 6m Distance minimum distance requ...

Страница 29: ...X X X 2 V V V X X X X 1 5 V V X X X X X 1 V V X X X X X 0 0 5 1 1 5 2 2 5 3 Total Horizontal Section Total vertical Section 23 V X X X X X X 22 V V V X X X X 21 O O V V V X X 20 O O O O 0 V V 19 O O O...

Страница 30: ...t 446 0330 24 446 0330 44 Burnerinjection 1200 3X 240 3X Type of flue C11 C31 C91 Additional electricity use At rated heat output elmax 9 5 kW With minimal heat emission elmin 9 5 kW In standby mode e...

Страница 31: ...with an eco label which is always supplied with the fireplace The ecolabel shows which category the fireplace belongs to G A ECOLABELS The ecolabels for the different types of gas are indicated below...

Страница 32: ...AWINGS On this page you will find trhr dimensional drawings of the Modore and Tenore 240 with some of the important dimensions that you have to take into account when installing and installing your fi...

Страница 33: ...32 Appendix H INSTALLATION MANUAL Figure H B Technical drawing of Tenore 240...

Страница 34: ...Info element4 nl www element4 nl 19 01 22 ELEMENT 4 B V Design Assembly by RELEASE DATE...

Отзывы: