INSTALLING THE GAS LINE
In accordance with the latest edition of the National Fuel Gas Code, NFPA 54 (USA) or CAN/CSA-B149.1 (Canada,) correctly size and
route the gas supply line from the supply regulator to the area where the appliance is to be installed.
Never use galvanized or plastic pipe unless it is rated for use with gas. Gas supply pipes must be designed, routed, constructed and
made of materials that are in strict accordance with local codes and regulations. A qualified plumber or gas fitter should be hired to
correctly size and route the gas supply line to the appliance in accordance with all applicable codes and regulations.
Installing a gas supply line from the fuel supply to the appliance involves numerous considerations of materials, protection, sizing,
locations, controls, pressure, sediment trap, and other criteria. The sizing and/or installing of gas piping should only be performed
by a qualified plumber or gasfitter.
The gas control inlet accepts a 3/8” NPT fitting.
The gas supply piping should have a separate gas shutoff valve and a capped,
1/8
” pipe tapping upstream of the valve for the purpose
of reading pressure. A service shutoff valve must be placed within six feet of the fireplace gas control valve.
The gas supply pressure at the gas control valve
must not exceed the
Maximum Supply Pressure
as shown in the
Specifications
and Dimensions
section of this manual
.
The gas supply line must be properly connected and bled by a certified gasfitter or plumber.
The appliance and its main gas valve must be disconnected from the gas supply piping system during any pressure testing of that
system at test pressures in excess of
1/2
psi (3.5 kPa). The appliance must be isolated from the gas supply piping system by closing
its equipment shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than
1/2
psi
(3.5 kPa).
Electrical work must be performed by a qualified, licensed electrician.
All wiring shall be in compliance with all local, city, and state codes.
WARNING
ELECTRICAL REQUIREMENTS
Two 120V AC receptacles are required for fireplace operation.
The Club 140 Series fireplaces use a mobile device app and/or remote control for their burner operation. The remote control comes
with two AAA batteries and its receiver is powered by a 120V AC adapter, included. The receiver
MUST
be powered by the AC
adapter. Four (4) AA batteries may be used for FLAME ONLY operation during a power outage. Remove batteries after use to avoid
battery corrosion. Battery corrosion will damage the receiver.
The LED lights and Wi-Fi Box are powered by a 24V power supply. The 24V power supply requires a 120V AC receptacle.
The installer must provide an approved 120V AC receptacle to be placed within the three foot cord limit of the 24V power supply.
ig
Содержание Club 240H C
Страница 2: ......
Страница 70: ...70 Element4 Gas Fireplaces Rev 01272020 www EuropeanHome com APPENDIX TWO ProControl Error Codes...
Страница 71: ...71 Element4 Gas Fireplaces Rev 01272020 www EuropeanHome com APPENDIX TWO ProControl Error Codes con t...
Страница 77: ...77 Element4 Gas Fireplaces Rev 01272020 www EuropeanHome com NOTES...
Страница 79: ......