background image

1 3

Chapter 8 

I N S T A L L A T I O N   M A N U A L   |

 ELECTRICAL CIRCUIT 

Figure 9.1

 shows a simplified connection circuit for the fireplace. Every 

fireplace is provided with a main adapter. 

8�1 

DOMOTICA 

The receiver offers the possibility to be connected to a domotica system. 

A special connector is being supplied for this. Type: G60- ZCE

8�2 

ELEMENT4 PROCONTROL APP� 

It is possible to operate your device via smartphone or tablet with the 

ProControl  App,  available  in  the  appstore  on  iOS  and  google  play  on 

Android. 

The app has a user friendly, interactive layout and the design is adjusted 
for Element4 devices. Up to eight devices can be used with one app, in 
the situation that multiple fire are installed in the same location. 

Another functionality of the app is to pre-set the temperature of you 

device, for a period of one week, to ensure yourself of an optimal desired 

room temperature. Also the device can changed between high and low 

flames and it features an eco-setting. 

The amount of users, that can operate the device is unlimited, so every 
family member can make use of it, by easily making a personal account. 
By two-way communication, one can check on the device at any moment. 

To use the app, the device needs to be provided with the correct receiver 

and remote combination. 

Necessities for the installation of the ProControl: 

• 

220 volt electricty near the fire 

• 

Wi-Fi code of the router

• 

Smart Phone or tablet 

• 

ProControl manual

Should any problems occur you can always check 

APPENDIX B

APPENDIX B

.

#

Description 

(1)

Gas Block

(2)

Receiver

(3)

Main Burner

(4)

Pilot set

(5)

Second Thermocouple

(6)

Adapter 6V

(7)

Wifi-Box

Table 8.1  | 

Componen ts

(2)

RELAIS

AUX
MODULE

(1)

(3)

(6)

(7)

(4)

(5)

MERTIK MAXITROL

LED 1

LED 2

Receiver

RESET

Figure 8.1  | 

Schematic Electronic Circuit 

Содержание BIDORE

Страница 1: ...INSTALLATI O N MA NUAL INSTALLATI O N MA NUAL Please leave these instructions behind with the device M O D O R E B I D O R E T R I S O R E 1 0 0...

Страница 2: ...INSTALLATION MANUAL i Do not use this product as a primary heat source...

Страница 3: ...ION 8 6 1 FIRE SAFETY DEVICE SET UP 8 6 1 1 PROTECTION OF WALL AND CEILING 8 6 2 ASSEMBLY REGULATIONS 8 6 2 1 GENERAL ASSEMBLY REGULATIONS 8 6 2 2 ASSEMBLY REGULATIONS FOR NON FLAMMABLE MATERIALS 8 6...

Страница 4: ...OR MALFUNCTION 19 A B NECESSARY TOOLS 23 B ERRORS CODES PROCONTROL APP 24 B A MESSAGES SHOWN IN APP 24 B B MESSAGES SHOWN IN REMOTE 25 C FAULTS AND ERROR CODES IN THE REMOTE 26 C A F41 ERROR 26 C B RO...

Страница 5: ...nted to the device Make sure it is accessible at all times This device may not be used a primary heat source This device is designed to be used with natural gas or LPG The device can only be used with...

Страница 6: ...sembly error or material defect Element4 will provide a free replacement part to the installer without compensation for disassembly or montage 5 In case the installer is not able to fix the problem hi...

Страница 7: ...ON 1 2 OFF Figure 3 1 Remote and ignition sign Figure 3 2 Gas Block Figure 3 3 Top and side view of the Receiver 4 2 IGNITING THE PILOT LIGHT Check that the control knob A is in the ON position Figur...

Страница 8: ...e in the near vicinity of the device Position the gas connection such that it is always accessible for service purposes The gas block and receiver are under the combustion chamber in the deivce so tha...

Страница 9: ...objects e g built in furniture or wooden panels are mountedonthesideofthewallthatisturnedawayfromthefireplace For these types of installations please refer to CHAPTER 6 2 3 CHAPTER 6 2 3 6 2 ASSEMBLY...

Страница 10: ...fireplace 200 C Table 6 1 Legenda 6 7 21 6 6 7 21 6 E d3 D F G I d1 H A2 B C d2 Figure 6 4 C31 Flue situation Flammable materials 6 7 21 6 RQ 5 1 339 0 4 81 66 27 5 6 63 0 16 216 5 1 0 0 7 56 685 1 6...

Страница 11: ...enclosure ventilation opening are necessary Figure 6 5 The ventilation grills are to be placed at a minimal distance of 20cm from the ceiling and 30cm from any built in furniture from the side any fla...

Страница 12: ...ee APPENDIX E APPENDIX E you search for the corresponding calculation tables Each category refers to a set of tables 1 A table for horizontal outlet 2 A table for vertical outlet 3 A table for reducti...

Страница 13: ...FLUE MATERIAL Follow the following instrucions for the installation of flue materials Drill a hole of 160 mm for the wall or roof transit with a 150 mm diameter flue connection and 210 mm with a flue...

Страница 14: ...erature of you device for a period of one week to ensure yourself of an optimal desired room temperature Also the device can changed between high and low flames and it features an eco setting The amou...

Страница 15: ...re removed in as in step 10 1 1 Remove the ropes holding the glass See Figure 9 3 Put the section cup on the glass and make sure it is properly vaccuumed so it will not come off See Figure 9 4 Lift th...

Страница 16: ...15 Chapter 9 INSTALLATION MANUAL Figure 9 2 Remove side trims Figure 9 3 Put on suction cup Figure 9 4 Remove Glass ropes Figure 9 5 Remove Windows...

Страница 17: ...this is the case check the burner pressure at the inlet to the burner The instructions of changing the burner pressure and the correct pressure per gastype can be found in 9 3 2 PILOT The pilot flame...

Страница 18: ...of the appliance 10 DECORATIVE CERAMIC PARTS This appliance is equipped with a ceramic fire bed with heat resistant ceramic fibers or artificial glassy silicate fibers Excessive exposure to this mate...

Страница 19: ...ble plus button to switch between burners Flames and soot During this first fire examine the flame for appearance and quality Flames may appear blue at first but will turn yellow after 15 to 20 minute...

Страница 20: ...turbs the reception Change the position of the antenna See Figure A B C No ignition no beep 1 Receiver defective Reset the receiver See K1 If necessary replace the receiver D No ignition receiver give...

Страница 21: ...Appendix A INSTALLATION MANUAL Figure A A Bend pin Figure A B Antenna Figure A C Torx screw Figure A D Testpoint 4 5 mV 4 5 mV Figure A E Interrupter Figure A F Wiring receiver 40mm Figure A G Pilot s...

Страница 22: ...ouple Position burner grate 3 Airflow in the burner chamber causes a restless fire image Check drain configuration Fit a flue gas limiter I Receiver gives 3 short beeps after each command 1 Batteries...

Страница 23: ...Aux position receiver AM PM ON 1 2 OFF Figure A L Double plus button on the remote Figure A M SI port PANEL G60 ZCE 1000 MA GR MO SW 2 1 3 MODE Ignition Main Burner High Flames Pilot Extinguish Main...

Страница 24: ...ed Please note If a problem is found that cannot be solved on site always contact your dealer or directly contact Element4 via our credentials which can be found on the back page of this manual 00 00...

Страница 25: ...eeps for 3 sec during motor turn Low Receiver battery power supply F10 Contact Service Pilot lit Main burner fails to ignite and pilot shuts off Ignition is blocked for 2 minutes 2nd thermocouple is o...

Страница 26: ...mmunication between Receiver and myfire Wi Fi Box F44 Contact Service No temperature shown in App N a not applicable displayed in App Handset not within range Low battery power in handset F49 Contact...

Страница 27: ...istances from occurring Many people put the router in the meter cupboard because that is where the internet comes in at many households A bad choice For a powerful WiFi signal the router needs as much...

Страница 28: ...NAL LOCATION WITH VERTICAL EXHAUST C11 Distance Exhaust 1 2 of 3 At the same roof level 6m At a different roof level 3m On a lower wall 2m On a higher sloping surface 6m Distance minimum distance requ...

Страница 29: ...V 4 O O O O O V V V V 3 5 O O O O O V V V V 3 V V V V V V V V V 2 5 V V V V V V V V X 2 V V V V V V V X X 1 5 V V V V V V X X X 1 V V V V V X X X X 0 0 5 1 2 2 5 3 5 4 4 5 5 Total Horizontal Section T...

Страница 30: ...urnerinjection 1200 240 Type of flue C11 C31 C91 Additional electricity use At rated heat output elmax 9 5 kW With minimal heat emission elmin 9 5 kW In standby mode elsb 9 5 kW Power requirement for...

Страница 31: ...lways supplied with the fireplace The ecolabel shows which category the fireplace belongs to G A ECOLABELS The ecolabels for the different types of gas are indicated below respectively G20 G25 and G30...

Страница 32: ...DRAWINGS On this page you will find the dimensional drawings of the Fireplace with some of the important dimensions that you have to take into account when installing and installing your fireplace Fi...

Страница 33: ...32 Appendix H INSTALLATION MANUAL Figure H A Dimensional drawing of the Bidore 100...

Страница 34: ...33 Appendix H INSTALLATION MANUAL 119 420 235 714 918 1000 280 1036 338 980 47 311 165 420 200 930 980 170 427 Figure H A Dimensional drawing of the Trisore 100...

Страница 35: ...Info element4 nl www element4 nl 26 01 22 ELEMENT 4 B V Design Assembly by RELEASE DATE...

Отзывы: