Element P303BT User Guide I Page 44 of 53
Message Length
Message length can be set to the maximum value, minimum value. The data is valid between the maximum and the
minimum.
The maximum value and minimum value can be set using Programming command. Please check the programming
command guide for the detail.
PDF417 max length command: 021F06. The parameter of this command can be set from min to 2750.
PDF417 min length command: 021F05. The parameter of this command can be set from 1 to max. Example: Set the
Barcode Message length of the minimum value is 10; the maximum value is 25.
Programming command: Max: 021F0625 ; Min: 021F0510.
5.16
QR Code
Enable/Disable QR Code
Enable QR Code (Default)
Disable QR Code
Message Length
Message length can be set to the maximum value, minimum value. The data is valid between the maximum and the
minimum is valid.
The maximum value and minimum value can be set using Programming command. Please check the programming
command guide for the detail.
QR max length command: 023703. The parameter of this command can be set from min to 7089.
QR min length command: 023702. The parameter of this command can be set from 1 to max.
Example: Set the Barcode Message length of the minimum value is 10; the maximum value is 25.
Programming command: Max: 02370325 ; Min: 02370210.
QR Code Append
This function allows the scanner to append several QR barcode data together before transmitting to host. When the
scanner encounters a QR barcode with append character (ex. Space character), it buffers the data until it reads a QR
barcode which does not have append character. Then the data is transmitted in the order that the barcodes were read.