Symbologies
5.1
General Setting
5.1.1
Enable/Disable All Symbologies
If the
Disable All Symbologies
feature is enabled, the engine will not be able to read any non-programming barcodes
except the programming barcodes.
Enable All Symbologies
Disable All Symbologies
5.2
Code 128
Enable/Disable Code 128
Enable Code 128 (Default)
Disable Code 128
Message Length
Message length can be set to the maximum value or minimum value. The value between the maximum and the
minimum is valid.
The maximum value and minimum value can be set using “
Programming C
ommand”. Please check the programming
command guide for the detail.
Code 128 max length command: 020A03. The parameter of this command can be set from min to 90.
Code 128 min length command: 020A02. The parameter of this command can be set from 0 to max.