background image

3

ing regulations. It is therefore recommend that 

a registered gas installer be employed for this 

task. The engineer will provide you with informa-

tion about the safety limits of the installation and 

should fix a notice plate in a place where it can 

be readily seen.

This appliance is designed as an efficient heating 

device and consequently all body parts become 

very hot in use. Except for the control knob and 

control access door, which are designed to stay 

cool, all other parts are working surfaces and 

should not be touched.

The glass and frame on this appliance acts as 

a fireguard conforming to BS: 1945 – 1971 and 
satisfies  the  Heating Appliance  (Fireguards) 

regulations 1991. No part of the window or frame 

should be permanently removed. 

It does not 

give protection for young children aged or 
infirm

, extra guarding(conforming to BS8423: 

2002)  should  be  considered  so  the  special 
hazards that exist in nurseries and other places 
where there are young children, aged or infirm 

persons are minimized.

Bearing in mind that the heat given off by this 

appliance may affect articles placed close to it, 

curtains should not be placed within 30cm.

The appliance is not designed as a dryer. It is not 

therefore recommended that the appliance be 

used in such a manner. Do not place any articles 

within 30cm of this appliance as this may result 

in damage to the articles.

The installation must be carried out in accord-

ance with the following regulations:

The Building Regulations issued by the Depart-

GENERAL INFORMATION

Important Safety Notice

This appliance has a ceramic Fire-bed arrange-

ment; this contains Refractory Ceramic Fibres, 

which  are  man-made  vitreous  silicate  fibres. 
Excessive  exposure  to  these  materials  can 

cause irritation to eyes, skin and respiratory 

organs. Hence we recommend that when han-

dling these materials the release of dust should 

be kept to a minimum. During installation and 

servicing we recommend that a HEPA filtered 

vacuum be used to remove any dust and soot 

in  and  around  the  fire.  If  any  of  the  ceramic 
fire-bed  components  need  to  be  replaced  we 

recommend that the removed parts be sealed in 

a heavy-duty polythene bag, and be labelled as 

RCF waste. RCF is not “Hazardous waste” and 

can be disposed of at a licensed tipping site for 

the disposal of industrial waste.

The appliance incorporates a permanent pilot. 

This is located on the front of the burner, and 

must not be adjusted by the installer. This system 

must not be put out of operation, and if any parts 

require changing, only original manufacturer 

parts shall be used.

This appliance is designed to be used either 

Natural or LPG gas however, each individual 

appliance is only capable of running off the type 

of gas specified at the time of purchase. It is im

-

portant to note that once a type of gas has been 

specified the stove cannot run off any other type. 

The type of gas that your stove is capable of 

burning is stated on the data information panel.

This appliance has been designed, tested and 

approved to meet standards in place for prod-

uct use, performance and safety. Installation of 

your appliance must comply with current build-

Содержание Bidore

Страница 1: ...ustomer for future reference User and installation manual Trisore 95 Bidore 95 Trisore 70 Bidore 70 WARNING THE COMBUSTION CHAMBER OF THIS STOVE SHOULD ONLY BE OPENED AND SERVICED BY A REGISTERED GAS INSTALLER i e GAS SAFE REGISTERED ENGINEER GB ...

Страница 2: ...oncentric Flue Parts Identification 14 Rigid Balanced Flue Connection Possibilities 21 Wall Terminal Terminations 21 Vertical Roof Terminations 22 Installing Remote Control Electronic Ignition System GV60 25 Arranging The Ceramic Fire bed 26 Log Arrangements 26 Gravel Arrangements 28 COMMISSIONING THE APPLIANCE 28 Installing the fire 29 Servicing Instructions 28 Troubleshooting 29 TECHNICAL INFORM...

Страница 3: ... Regulations issued by the Depart GENERAL INFORMATION Important Safety Notice This appliance has a ceramic Fire bed arrange ment this contains Refractory Ceramic Fibres which are man made vitreous silicate fibres Excessive exposure to these materials can cause irritation to eyes skin and respiratory organs Hence we recommend that when han dling these materials the release of dust should be kept to...

Страница 4: ... has been broken removed or is open Note Since the appliance is a source of heat circula tion of air occurs Therefore it is of importance that you do not use the appliance shortly after a renovation of the home Because of the natural circulation of air moist and volatile components from paint building materials carpet etc will be attracted These components can settle themselves down onto cold surf...

Страница 5: ...plication into operation a communication code must be set between the remote control and the receiver The code is cho sen randomly from the 65000 available codes As a result the chance that other remote controls near you are using the same code and affect the operation of your appliance is very small Follow the procedure described below Hold down the reset button on the receiver until you hear two...

Страница 6: ...t button A on the gas control to ON button B is controlled automatically The gas control is located in the control hatch or is placed under the appliance Simultaneously press the buttons OFF and large flame on the remote control Let go of the buttons when a short sound signal indicates that the ignition process has been started In succession the continuous signals will indicate that the ignition p...

Страница 7: ...ously press OFF and small flame until the correct display appears Time The display can indicate time After placing the battery or simultaneously press ing large flame and small flame the time indication will flash on the display and you will be able to adjust the time Simultaneously press and until the time in dication flashes on the display Press the button large flame to set the hours Press the ...

Страница 8: ...h the following steps Place the appliance in the standby pilot burner position using button small flame Set the day night temperature Choose the TEMP or TEMP function using the SET button Timer for thermostat function Using the timer enables you to set two times per 24 hours for switching on the day temperature and two times per 24 hours for switching on the night temperature In order to control t...

Страница 9: ... steps below for activating the timer control Place the appliance in the standby pilot burner position using button small flame Set the day night temperature if you have not yet done so Set the timer times P1 TIMER P1 TIMER P2 TIMER and P2 TIMER Choose the P TIMER function using the SET button Replacing the battery If the battery is almost empty the display will show BATT To replace the battery pr...

Страница 10: ...ulted If the chimney has been previously used it must be professionally cleaned and certi fied as being sound and fit for use The European CE approval on this appliance is restricted to the Flue systems as specified by the supplier thus the appliance must only be installed with the original flue system no others may be used The gas fire in combination with the concentric flue system has been appro...

Страница 11: ...be referenced e g Gas Installations in Tim ber Frame Buildings from the CORGI installer series in the UK Carport or Building Extension Where a flue terminal is sited within a carport or building extension it should have at least two completely open and unobstructed sides The distance between the lowest part of the roof and the top of the terminal should be at least 600mm Note A covered passageway ...

Страница 12: ...oil pipe 300 H From an internal or external corner 600 I Above ground roof or balcony level 300 J From a surface facing the terminal 600 K From a terminal facing the terminal 600 L From an opening in the car port e g door window into the dwelling 1200 M Vertically from a terminal on the same wall 1500 N Horizontally from a terminal on the same wall 300 P From a vertical structure on the roof 600 Q...

Страница 13: ... 1 m higher than the intake supply opening or a window that can be opened If the required distance cannot be achieved the position of the outlet must be at least 1 m above the highest facade roof Important note for Roof Terminations C31 When installing the appliance with a roof termination classification C31 it is important to fit a flue restriction strip across the flue outlet inside the stove se...

Страница 14: ...oncentric Flue Pipe 1m Length US 100 100 US 100 130 4 Locking Band USKB 100 USKB 130 5 Protection Band USAB 100 USAB 130 6 Concentric Flue Pipe Adjustable Length 50 300mm USPP 100 USPP 130 7 Vertical Terminal USDVC2 100 8 Horizontal Terminal Excentric Exit Ø100 USDHCE 100 9 Mounting Band USEB 100 USEB 130 10 Wall Band Adjustable USMB 100 USMB 130 11 Concentric Flue 90 USB 90 100 USB 90 130 12 Conc...

Страница 15: ...15 installer information ...

Страница 16: ...16 installer information ...

Страница 17: ...17 installer information ...

Страница 18: ...18 installer information ...

Страница 19: ...19 installer information 22 USVK 100 130 REDUCER Ø130 Ø100 23 USDHC 130 HORIZONTAL TERMINALØ130 ...

Страница 20: ...20 installer information 24 USBI 100 130 Elbow 90 with inspection cover 25 USI 100 130 Inspection Element ...

Страница 21: ...egree bend 20 cm Maximum height V whilst using a wall terminal 3 meter Horizontal possibilities 0 5 meter vertical gives maximum horizontal 6 meter Bidore 95 Trisore 95 Diameter Concentric Flue 200 130 Minimal vertical height V is 0 5 meter Maximum vertical height V whilst using a wall terminal 3 meter Horizontal possibilities 0 5 meter vertical gives maximum horizontal 2 meter 1 0 meter vertical ...

Страница 22: ... termination classification 31 it is important to fit a flue restrictor across the flue outlet inside the fire Roof terminations will need the 60 mm flue restrictors fitting This is delivered with the fire Distance V 1m 11m min max We recommend using flue reducer USVK to flue dimension 150 100 ...

Страница 23: ...23 installer information Vertical Roof Mounted Termination with Elbow for Rigid Concentric Flue We recommend using flue reducer USVK to flue dimension 150 100 ...

Страница 24: ...24 installer information Vertical Roof Mounted Termination with Angled Elbow for Rigid Concentric Flue We recommend using flue reducer USVK to flue dimension 150 100 ...

Страница 25: ...line and 9V PP3 alkaline respectively Setting the electronics code The receiver has to select the code of the hand set please follow the procedure 1 Power up handset 2 Power up receiver LED flashes 3 Push reset button on receiver till long beep 4 Push flame high or flame low button on sender till short beep 5 Gas fire is now ready for ignition See options in user part The receiver unit can be hidd...

Страница 26: ...te aligning with the centre slots on the Burner Tube The Pilot flame must be visible through the grate and the cut out in the Pilot Shield Make sure there is a 1 cm gap between the back log and the back wall of the fire INFORMATIE VOOR DE INSTALLATEUR Ensure that a number of holes in the Grate and the Pilot area are free of embers After placing the embers and logs according to the figures sprinkle...

Страница 27: ...in the centre of the Grate aligning with the centre slots on the Burner Tube The Pilot flame must be visible through the grate and the cut out in the Pilot Shield Make sure there is a 1 cm gap between the back log and the back wall of the fire Ensure that a number of holes in the Grate and the Pilot area are free of embers After placing the embers and logs according to the figures sprinkle some as...

Страница 28: ...the appliance with the customer Gravel Arrangements Blackstones Brilliants Ensure that the Grate is sitting firmly in the base of the fire box with the long slot in the centre of the Grate aligning with the centre slots on the Burner Tube The Pilot flame must be visible through the grate and the cut out in the Pilot Shield Scatter evenly the Gravel over the top of the Grate and Burner Make sure th...

Страница 29: ... your convenience a special service door from Element4 is available BDLE4 The plaster of the outside has to be resistant to a high temperature Use therefore the plaster materials especially made for this to prevent discoloring min 100 degrees C temperature re sistant If the appliance is to be fitted against a wall with combustible cladding the cladding must be removed from the area covered by the ...

Страница 30: ...e the metal clamps which hold the glass window in place top and bottom glass window See figure 4 Now remove the glass window by lifting the glass and then bring it forward See figure 5 When the glass window is placed back again DON T tighten the screws of the metal clamps too tight This brings tension and might cause the glass window to break Figure 4 Figure 5 Figure 2 Figure 3 ...

Страница 31: ...is required then the engineer should check the setting pressure at inlet to burner the correct pressure is shown at the rear of the manual Brush off and replace ceramic arrangement as earlier in this manual replacing any broken or damaged pieces Check all seal on door including glass and replace the Door Check the installation for gas leaks Check flue for clearance of products of combus tion If an...

Страница 32: ...e re mote control within 20 sec until you hear an extra long sound signal confirming that the new code has been set 2 Replace batteries Caution Avoid short circuit between the batteries and metal parts of the appliance 3 Replace the receiver and confirm the code remedy 1 4 Replace the remote control and confirm the code remedy 1 5 Replace the motor cable 6 Make sure that the pins of the 8 wire connec...

Страница 33: ...he cable shoe The cable shoe is located on the outside directly next to the magnet nut at the rear of the gas control The voltage should be at least 5mV within 20 seconds It may not be lower when the appliance is warm If the voltage is too low the thermocouple should be placed bet ter in the flame or the thermocouple should be replaced 1 2 Check the size of the pilot burner flame Correct a flame that...

Страница 34: ...34 Technical drawings techniCAL INFORMATION Trisore 95 Bidore 95 ...

Страница 35: ...35 technical information Bidore 70 Trisore 70 ...

Страница 36: ...stonia ü I2H G20 20mbar ES Spain ü I2H G20 20mbar FI Finland ü I2H G20 20mbar FR France ü I2E G20 G25 20 25mbar GB United Kingdom ü I2H G20 20mbar GR Greece ü I2H G20 20mbar HR Croatia ü I2H G20 20mbar HU Hungary IE Ireland ü I2H G20 20mbar IT Italy ü I2H G20 20mbar LT Lithuania ü I2H G20 20mbar LU Luxembourg ü I2E G20 20mbar LV Latvia ü I2H G20 20mbar NL The Netherlands ü I2L G25 25mbar NO Norway...

Страница 37: ...dom ü I3B P G30 G31 30mbar I3 G30 G31 28 30 37mbar GR Greece ü I3B P G30 G31 30mbar I3 G30 G31 28 30 37mbar HR Croatia ü I3B P G30 G31 30mbar HU Hungary ü I3B P G30 G31 30mbar IE Ireland ü I3 G30 G31 28 30 37mbar IT Italy ü I3 G30 G31 28 30 37mbar LT Lithuania ü I3B P G30 G31 30mbar LU Luxembourg LV Latvia MT Malta ü I3B P G30 G31 30mbar NL The Netherlands ü I3B P G30 G31 30mbar NO Norway ü I3B P ...

Страница 38: ...reby declare that the design and construction of Element4 s atmospheric gas heating ap pliance comply with the essential requirements of the Gas Appliance Directive Product atmospheric gas heating appliance Type Trisore 95 Bidore 95 Trisore 70 Bidore 70 Applicable EEC directives 90 396 EEC Applied harmonized standards NEN EN 613 NEN EN 613 A1 Internal measures by the company guarantee that applian...

Страница 39: ...e factory warranty is valid for 12 months after date of purchase Trisore 70 and Bidore 70 PIN 0558CM1329 Natural Gas LPG Gas Category I2H I3B P I3 Supply Pressure mbar 20 30 28 30 37 Nominal Input 10 4 8 8 8 8 Gross kW Efficiency Class 2 2 2 Pilot Burner 446 0330 14 446 0330 07 446 0330 07 Gas Rate 0 990 0 252 0 252 max m3 hr Burner Pressure 11 3 27 3 27 3 mbar hot Injector Marking 1200 260 260 NO...

Страница 40: ...40 Element4 B V Paxtonstraat 23 8013 RP Zwolle The Netherlands ...

Отзывы: