8
EN
GLISH
APPROPRIATE USE
The GAS SENSOR GX-SE is a sensor for town, natural and liquid gas and is used as an
accessory with the gas warning devices in our product range.The sensor may not be used
in areas with a risk of explosion.Another use of the device as described above is not autho
-
rized.
TECHNICAL SPECIFICATIONS
Operating voltage:
5 V
Type sensor:
catalyitc
Humidity (ambient):
5–90 % RH (non-condensing)
Operating temperature:
-10 °C / +50 °C
Storage temperaturer:
-20 °C / +70 °C
Service life:
approx. 5 years
Protection type:
IP 20
Cable length:
2,5 m
Cable Ø:
3,5 mm
Dimensions (HxWxD):
52x27x29 mm
Data diagram Sensor
Gas type
Minimum concentration
CO
no alarm triggered
Methane
<5000 ppm (0,5%)
Propane (isobutane)
<2000 ppm (0,2%)
Ethanol (acetone)
<5000 ppm (0,5%)