16 Repair and maintenance
Please heed the current safety
and accident prevention regu-
lations during all maintenance
and repair work.
16.1 Check regularly
Check the following points for damage
before starting up the welding machine:
•
Mains plug and cable
•
Welding torch and connections
•
Ground cable and connection
Blow out the welding machine every two
months
Switch the machine off
Disconnect the mains plug
Unscrew both side panels of the unit
Blow out the welding machine with dry, low
pressure compressed air. Avoid blowing
directly on the electronic components from a
short distance, to prevent damage
Screw the two side panels onto the machine
back again
Never make repairs or technical
changes yourself
In this case the manufacturer's
warranty is no longer valid.
If you experience problems or
need repairs, contact a dealer au-
thorised by ELEKTRON.
16.2 Torch care
Remove the weld spatter from inside the
gas nozzle using suitable tongs.
Spray the inside surface of the gas nozzle
with a releasing agent, or use nozzle
protection paste.
This will prevent weld spatter from being
burnt on.