14 Messages
During operational faults / malfunction, the 7-
segment display 47 displays an error code.
As long as there is an error code on
display welding is not possible.
Code
Error description
Note
Rectification
E00
No program
Selected program number does not
exist
Select a different characteristic line
Instead of material thickness „ - - - „
is displayed and by pressing the
torch key „E00“ shows up. Welding
is not possible at activated charac-
teristic line and set welding step
Select a different welding step
E01
Excessive temperature
The equipment has been overheated Allow the system to cool down in
standby, check the ventilation system
E02
Mains over voltage
Mains input voltage too high
Check mains voltage
E03
Over current
Output current is too high / Perma-
nent short circuit
Inform Service
E04-1 Emergency STOP /
periphery fault (optional)
PE conductor monitoring input
(Fault current to protective earth
conductor) / Emergency STOP
activated
Check connection of the work piece
cable and ground clip, check for short-
circuits between welding wire and
housing / Check emergency stop chain
E04-2 Emergency STOP /
periphery fault (optional)
Gas pressure switch input activated Check inert gas
E06
Over voltage
Output voltage too high
Inform Service
E07
EEProm checksum error Setting data faulty or missing
Switch the equipment off and on again
E08
Wire feed
Too high power intake from wire
feed motor (Motor Over-Current)
Blow down torch package with
pressured air and check pressure on
wire feed rolls
E09
Voltage-measuring
Voltage measuring system defective Inform Service
E13
Temp. sensor error
Thermal sensor not ready for opera-
tion
Inform Service
E14
Supply voltage
Internal supply voltage too low
(18V~ / 24V-)
Check mains voltages
E15
Power measuring
Fault at power measuring
Inform Service
E16
Supply voltage motor
and main contactor
Internal supply voltage is too little
(42V~ / 60V-)
Check power supply voltage
E17
Periphery
overload / short circuit
Short circuit in torch or hose pack-
age, gas valve or feed line, wire run
key or line
Test alt. exchange the connected torch
E18
Error configuration
Faulty or wrong pc-board,
wrong software system played
Inform Service
Tab. 3:
Messages