page 34
REQUEST INFO MODE
number of cycles
00002
FUNCTION
INFO
PROG
To select INFO MODE set the switch to the central position, the display first shows the cycle
counter. It counts each full cycle. A full cycle means leaving and reaching the final close limit.
In
INFO mode shutter movements are not possible.
Pushing the arrow buttons UP and DOWN selects:.
Ï Ð
ESC
OK
number of cycles
Displays all movements after first installation
reset not possible.
last command
Displays the last command
last fault
Displays the last 2 faults
program change
at cycle count: XXX
Monitors program changes, only 3 numbers
( XXX ) at the counted shutter cycles
( XXXXX ) max. 5 numbers.
last maintenance
at cycle count: XXXXX
displays cycles from last maintenance
new maintenance
memory ?
Cycle count for the next maintenance can be
memorised.