page 21
Important note
When the limit switches ( S3 - S4) have not been operated
before being confirmed with OK, the control does not
recognise the commands and goes into fault mode. Display
shows escape.
Door OPEN >
Door CLOSE < OK ?
To exit use ESC
Final close
adjust
OK ?
To exit use ESC
Display appears, confirm with OK.
The control is now in the menu for setting the close
limit. The arrow buttons UP and DOWN are used to
move the shutter in DEAD MAN MODE to the final
close position to set the limit S4. See mechanical
instruction, setting the limits. The final close position
must be confirmed by pressing the OK button after
S4 has been operated when the door is moving.
After correct limit adjustment and switching over the selector switch to FUNCTION the control is
ready to operate in DEAD MAN MODE in the close direction.
In this mode only the foil keypad and the first external pushbutton are in enabled. The optional
second pushbutton terminals cannot be used.
ADJUSTMENT OF THE LIMITS/ BASIC-FUNCTION
ESC
OK
ESC
OK