Electrical operating instructions
Door control panel TS 980
(Design and functions subject to change)
51171150 -
b 07.2007
en
Страница 1: ...Electrical operating instructions Door control panel TS 980 Design and functions subject to change 51171150 b 07 2007 en...
Страница 2: ...ce evaluation 1K2 with normally open safety edge contact 9 Resistance evaluation 1K2 with normally closed safety edge contact 10 Resistance evaluation 8K2 with normally closed safety edge contact 11 O...
Страница 3: ...he automatic close feature 27 ADJUSTMENT AUXILIARY FUNCTIONS 27 Adjustment relay contact 1 pre information mechanical limit NES operation 28 Adjustment relay contact 2 30 Adjustment of pre limit 31 Ad...
Страница 4: ...al commercial and garage doors and gates Safety in use of power operated doors Requirements DIN EN 12978 Industrial commercial and garage doors and gates Safety devices for power operated doors Requir...
Страница 5: ...onnection an all pole main switch with appropriate back up fuse must be provided Check live cables and conductors regularly for insulation faults or breakages When a fault is detected in the cabling t...
Страница 6: ...ALLATION Before mounting the enclosure the surface has to be checked for flatness slope and freedom from vibrations For installation we recommend to use the template supplied Mounting must be vertical...
Страница 7: ...N PE 3 x 400V PE 3 x 230V PE 1 x 230V N PE Warning This indicates danger to the life through electric shock Before starting assembly disconnect the equipment from the electricity supply The control pa...
Страница 8: ...Resistance evaluation 8K2 with normally closed safety edge contact page 11 Optical safety edge system Fraba type page 11 Important note When connecting a safety edge make sure of compliance with DIN...
Страница 9: ...edge with 8K2 resistor and normally open contact This evaluation system is made for electrical safety edges within an end of line resistor of 1K2 The resistor must be connected in series with the swi...
Страница 10: ...essure wave activates the pressure switch in this time the TS 980 recognises the function of the safety edge If the pressure switch has not been activated the control goes into fault mode and the syst...
Страница 11: ...resistor of 8K2 When a normally closed safety edge system which works in quiescent current mode is connected a separate safety edge control has to be connected The resistor must be connected in serie...
Страница 12: ...ere lifting of people or obstacles cannot be prevented e g Grilles A separate control system within an end of line resistor of 1K2 should be connected TS 980 recognises various faults short circuit co...
Страница 13: ...tic closing mode can be programmed only when a beam is connected see program In accordance with EN 954 1 the beam has to meet category B Fig 4 Wiring diagram for reflective photo beam Important note P...
Страница 14: ...ad man mode control The Second push button can be installed at any other place and the door movement has not to be controlled When the control goes into fault mode the second pushbutton will be disabl...
Страница 15: ...F position the shutter works in standard mode With each command impulse the shutter responds as follows Shutter position Shutter mode Shutter closed Shutter moves to open position Shutter moving open...
Страница 16: ...Signal light green no function Switch contact no function only possible when the intermediate stop is not required when using a mechanical limit When using DES all functions are available The relay c...
Страница 17: ...page 17 PCB PRINT OVERVIEW S1 1 S2 2 1 MODULE POCKETS FOIL KEYPAD...
Страница 18: ...ich recognises DES digital limits or NES mechanical limits this needs max 5 sec adjust limit FUNCTION INFO PROG FUNCTION INFO PROG On initial installation the SELECTOR SWITCH must be set to PROG To mo...
Страница 19: ...he arrow buttons UP and DOWN choose SELECT LANGUAGE and confirm with OK The display will show D German GB English F French Move UP and DOWN with the arrowed buttons and confirm the required language w...
Страница 20: ...ol is now in the menu for setting the limits The arrow buttons UP and DOWN are used to move the shutter in DEAD MAN MODE to the final open position to set the limit S3 See mechanical instruction setti...
Страница 21: ...sed to move the shutter in DEAD MAN MODE to the final close position to set the limit S4 See mechanical instruction setting the limits The final close position must be confirmed by pressing the OK but...
Страница 22: ...DEAD MAN MODE to the final open position The final open position must be confirmed by pressing the OK button Display shows final limit close position Follow same commands as before for final close li...
Страница 23: ...etc each step changes the final limit switch position by about 5 mm New final limit position must be confirmed with OK After fine adjustment switch over the selector switch to Function the door positi...
Страница 24: ...tem is connected the display shows safety edge system not available and the door will move only in DEAD MAN MODE in the downwards direction A defective safety edge system has the same effect To exit u...
Страница 25: ...To change the safety edge function after the pre limit has been operated reaction STOP For both functions S5 has to be set 5 cm before the shutter final close position see page 31 Important note in co...
Страница 26: ...position is reached in DEAD MAN MODE Pre limit S6 must be switched once to set the memory in the control If the function works correctly the control confirms set If S6 has been chosen for intermediat...
Страница 27: ...g the arrow button a number between 0 and 2 can be set and confirmed with OK The second figure blinks on tens and by pushing the arrow button a number between 0 and 9 can be set and confirmed with OK...
Страница 28: ...ould not be interrupted set the arrow before no and confirm OK This will be shown after automatic close feature See description relay contact page 16 The TS 980 has 2 potential free relay contacts ava...
Страница 29: ...start of the closing cycle Adjustment is the same as the automatic closing feature and must be confirmed by OK With the arrowed button the required time can be selected and confirmed by OK When pre wa...
Страница 30: ...utton the display shows no function with the arrowed button the required function can be selected Information with mechanical limits NES the function relay contact 2 is only available if the inter med...
Страница 31: ...tivate Arrow set before active the safety edge is enabled after the rpe limit or if the arrow is set before inactive the safety edge is disabled after the pre limit is reached Important note in connec...
Страница 32: ...ctive or inactive can be selected This display appears automatically after the pre limit function is selected When this function is required it must be confirmed by OK The control supplies only two po...
Страница 33: ...ation at the close limit the shutter could be open 1 cm This fault can be corrected with switching the final limits by shutter movement correction lower limit active inactive ESC OK Final close FUNCTI...
Страница 34: ...ible Pushing the arrow buttons UP and DOWN selects ESC OK number of cycles Displays all movements after first installation reset not possible last command Displays the last command last fault Displays...
Страница 35: ...push button switch Key switch Key switch with emergency Stop Emergency Sop button Slack wire switch Internal red green light External red green light Connection cable NES Connection cable DES 4 core...
Страница 36: ...page 36 CONFIGURATION PLAN FOR LIMIT SWITCHES M 3 G1...
Страница 37: ...twice touched an obstacle new command demanded command Stop continuous Stop bridge 1 to S1 or 2 to S2 not available command open continuous command pushbutton fault command close continuous command pu...
Страница 38: ...using 10A delay Supply for external devices 230V supply with neutral fuse 2A delay 24V DC max current 150mA output short it circuit safe Power input control 15VA Max realy contact current 230V AC 2A C...