background image

2

DESCRIPTION

PT23 is digital room thermostat with backlit display for automatic regulation of heating. 

Its advantages involve a quick change in the desired temperature by simply press the button, and 

possibility of setting up to weekly program with 6 temperature changes per day.

INSTALLATION

LOCATION

Install the thermostat at a suitable place where its operation cannot be affected by direct fl ow of 

hot air from the heater, sunshine or other disturbing effects. Do not install it on an external wall 

either. The installation height should be approx. 1.5 m above the fl oor. Place the thermostat in 

the “reference room”, such as the living room (the heating source will switch according to the 

temperature in this room).

1. 

Switch off the main circuit breaker. 

2. 

Remove the control part from the lower cover of the device (Fig.1). 

3. 

Chip away the central plastic piece from the lower cover to lead in conductors.

4. 

Run the conductor through the hole and connect it to the terminal acc. to the diagram.

5. 

Fasten the lower cover to the wiring box with screws (Fig. 2). 

6. 

Batteries are located at the back of the control part. Remove their protective paper (on fi rst use), or insert new 

batteries (Fig. 3). 

7. 

Mount the control part on the lower cover. 

8. 

Switch on the main circuit breaker and test correct connection of the thermostat, see page 5 (TEST).

9. 

Upon fi rst start (or reset), the thermostat displays “SET CLOCK”, set the current time and date according to page 4.

Wiring diagram:

Backlit display

if any button is 

pushed, the backlit 

switches on 

automatically for 5 s 

at least

Control elements

by pressing

= confi rmation of 

value chagne

by pressing

= entering of main 

menu or one step 

back

by pressing

= changing the 

   set value 

*

The thermostat terminals 

are marked differently with 

every type of boiler. 

Therefore, follow the 

wiring prescribed 

by the boiler 

manufacturer!

 

 

*

BOILER

Содержание PT23

Страница 1: ...s with ON OFF weekly program preset 6 temp changes per every day anti freeze mode easy installation modern design for all types boilers with LARGE WELL ARRANGED DISPLAY WITH TOUCHING CONTROL ROOM THERMOSTAT WITH BACKLIT DISPLAY ...

Страница 2: ... 3 Chip away the central plastic piece from the lower cover to lead in conductors 4 Run the conductor through the hole and connect it to the terminal acc to the diagram 5 Fasten the lower cover to the wiring box with screws Fig 2 6 Batteries are located at the back of the control part Remove their protective paper on first use or insert new batteries Fig 3 7 Mount the control part on the lower cov...

Страница 3: ... on the display you must replace the batteries 1 Remove the control part from the lower cover of the device Fig 1 2 Replace the batteries Heed the correct polarity marked in the battery compartment Fig 3 After removing the batteries all setting of the thermostat are saved in the memory 20 sec only Always use the type AA 2x1 5 V alkaline batteries Recommendation Check the batteries before every hea...

Страница 4: ... confirm with the button weekly program is factory set see page 8 Press the button twice using the buttons choose the MANU Mode and confirm with the button anti freeze temperature of 3 C is kept can not be changed Press the button twice using the buttons choose the OFF Mode and confirm with the button Press the button twice with buttons choose the and confirm with the button Stepwise set the tempe...

Страница 5: ...the button to confirm The 2nd change time appearsonthedisplay Proceedinthesamewayaswiththefirstchangesetting In this way you can set up to 6 temperature changes per day To return to the menu press the button After changing the preset program check whether all the changes made conform to your requirements It is not necessary to apply all six changes in one day Press twice the button by using button...

Страница 6: ...Status line dynamically changing according to the process running 14 Low battery indication TIME CHANGE YES VERSION DISPLAY DESCRIPTION 5 6 SUMMER WINTER time change VERSION restoring the default settings By choosing YES with buttons you can activate automatic SUMMER WINTER time change according calendar You don t need to take care about the time change thermostat make automatic setting for actual...

Страница 7: ...e Setting of week programms P1 P2 AUTOMATIC MODE MANUAL MODE OFF MODE thermostat is permanent switched OFF Antifreeze protection 3 C is still active HOLIDAY Setting of required temperature and point of holiday ending Summer winter time change Firmware version factory setting Touch sound 2 or Clock Setting Programming Constants level 0 level 1 level 2 CONTROL MENU PROGRAMING METHOD HOLIDAY ...

Страница 8: ...ies preset weekly program powered by batteries 2 x 1 5 V AA 6 temp changes per day programming by 10 minutes and 0 5 C programming day by day or Mon Fri Sat Sun or Mon Sun anti freeze protection 3 C short term change in the required temp auto SUMMER WINTER time change big backlit display output potential free contact max 5 A 250 V AC intuitive navigation in the selected language CZ SK PL EN DE RU ...

Отзывы: