1.
Battery Power
2.
Funtion Gen
3.
Tool to be tested (actuator)
Proceed as follows:
1.
Connect the clamps to the vehicle battery.
2.
Connect the terBATT and DRIVE to the actuator or device that you
wish to test; using, if necessary, the accessories supplied.
3.
Follow the instructions supplied by the software.
4.
Start mode PWM CURRENT DRIVE through the software.
Below are described some test examples that is possible to operate in
mode
PMW CURRENT DRIVE
.
In addition to these it is possible to list, including but not limited to:
•
EGR and FLOW METER diagnosis.
•
Diagnosis of variable-geometry turbocharger blades, with engine on.
•
Diagnosis of A/C pressure sensor.
•
A/C compressor diagnosis.
•
Seal diagnosis of diesel common rail injectors.
•
Diagnosis of flow regulator and common rail high pressure pump.
•
Flow and seal diagnosis of diesel common rail injectors.
Cable with code 3903843 is part of the cables kit for signal generator
(optional).