EN
Instruction Manual
PSI 8000 2U Series
Date:04-26-2011
6.6
Adjusting set values
As long as „
extern
“ or „
remote
“ are not shown in the display,
the set values for voltage, current or power can be set manually.
The mode is selected in the device setup at
Accept set va-
lue.
The setting can be accessed with
->
Profile
->
General settings
->
Control panel
the control panel“ for details.
Direct setting of the set values
Using the rotary knobs directly sets the set values.
The left rotary knob adjusts the voltage. The set value of the
voltage is displayed invertedly while it is selected and adjusted.
The right rotary knob either sets the set value for the current, for
the power (at models from 1kW) or internal resistance (optional,
unlockable, with U/I/R mode chosen). The selected set value
is displayed invertedly.
With the select keys
the set value for the power, with
the set value for the internal resistance or with
the set value for the current is selected.
The maximum adjustable power can also be limited.
Set values are submitted
Alternatively to the direct adjustment of set values you can
choose to set the set values only after submitting them with
the
RETURN
button. See section „7. Device configuration“ for
details. The set values can still be changed with the rotary knobs,
but are not set to the output as long as they’re not submitted.
While the set value is unchanged, only its unit is displayed inver-
tedly. If the set value is changed it is also displayed invertedly.
The
SELECT
keys switch from current adjustment to power
adjustment for the right rotary knob. The chosen set values are
not submitted to and set by the power supply until then.
Pressing the
RETURN
button submits the set values.
Pressing the
ESC
button discards the new set values
and the old set values are displayed again.
Note: the adjustment of the resistance set value is only
accessible after the optional „internal resistance control“
is unlocked (see section 7.8).
The resistance set value is adjustable from 0Ω up to
20* Unom/Inom. Means, for example, at a device with Unom
= 65V and Inom = 10A it can be adjusted to a maximum of
130Ω.
Using predefined set values
A table of up to 4 sets of set values is accessible in the menu
Preset List
(„7.2 Predefining preset lists“). The left knob
selects the preset list and with the
RETURN
button the set is
submitted or discarded with the
ESC
button.
The chosen set is still 1. After the
RETURN
button
is pressed, the set values of set 3 are submitted to the power
supply. The display then shows the new set values of set
3
.
The
ORY
button can be used to jump straight to the
menu page where the preset lists are defined and there they‘re
edited and submitted with
RETURN
as usual.
Step widths for set value adjustment
Voltage
Current
Nom. val Coarse Fine
Nom. val
Coarse Fine
32V
200mV 10mV 4A
50mA 1mA
40V
0.5V
10mV 5A
50mA 1mA
65V
0.5V
10mV 10A / 15A
0.1A
10mA
80V
0.5V
10mV 20A / 30A
0.2A
10mA
160V
1V
100mV 40A / 60A
0.5A
10mA
360V
2V
100mV 120A
1A
100mA
720V
5V
100mV
Power
Resistance
Nom. val Coarse Fine
Nom. value
Coarse Fine
640/650W 5W
100mW 13.3/16Ω
100mΩ 10mΩ
1000W
10W
1W
26.7/32/40Ω
200mΩ 10mΩ
1500W
10W
1W
53.3/64Ω
500mΩ 10mΩ
3000W
20W
1W
130Ω
1Ω
10mΩ
240/260Ω
2Ω
10mΩ
480/720/800Ω 5Ω
10mΩ
960Ω
10Ω
10mΩ
6.7
Switching the button panel
The button
PAGE
is used to switch to another button
panel. The new button assignments of the other panel allow the
user to lock the control panel, switch to the function manager
or set the location mode.
6.8
Locking the control panel
The button „Lock button panel“ locks all buttons, except
itself, and the rotary knobs. The unit is now locked from manu-
al acess, so that no set value can be changed or no menu is
accessible. The locking mode can be set up in the menu. The
control panel can be either completely inactive or it can exclude
the
OFF
button (the unit is then locked but can be switched off
and on by the
OFF
button). See also „Control panel lock“ in
section „7.4 Configuring the control panel“.
After the control panel was locked it changes to this
icon. The button can be used to unlock the control panel again,
if button
is pressed within the next 2s.
6.9
Changing the location mode
The unit can be set up to a location mode which doesn’t allows
it to be remotely controlled or switched to remote control by an
interface card.
With the button
EXT
the user enables the remote control
of the unit via an digital or analogue interface card and disables
the
local
mode.
With this button the user sets the unit into strict local
mode, so that it is only controllable locally (
local
), means by
hand and access by any interface, analogue or digital, is denied.
Using the power supply