17
Sensor and heating cable mounted
on the pipeline
Final Check
After the heating cable has been installed in the
gutter or in case of pipe installation, after thermal
insulation has been laid, perform the
measurements of the heating cable insulation's
resistance, and test-run the heating circuits to
assess the correctness and safety of the system's
operation.
The heating cable insulation's resistance, as
measured with an appliance of the rated voltage
1000 V (megaohmmeter), should not drop below
50 M . Enter the results into the Warranty Card.
Ù
Содержание SelfTec DW
Страница 2: ......
Страница 24: ......
Страница 45: ...SelfTec DW DWF ELEKTRA RU Instrukcja monta u PL Installation manual UK www elektra otoplenie ru...
Страница 46: ......
Страница 47: ...ELEKTRA SelfTec DW DW F 47 RU...
Страница 48: ...6 5 4 3 2 1 7 1 2 3 4 5 6 7 LDPE ELEKTRA SelfTec DW 48 SelfTec DW DWF ELEKTRA...
Страница 49: ...6 5 4 3 2 1 1 2 3 4 5 6 ELEKTRA SelfTec DW F 10 16 10 49...
Страница 54: ...54 SelfTec DW DWF ELEKTRA HL T 1 1 ELEKTRA SelfTec DW DW F EC PRO ECM25 PRO H LT H LT 1 2 3 4 1 1...
Страница 55: ...55 2 HL T 1 2 H LT 1 2...
Страница 56: ...56 HL T HL T SelfTec DW DWF ELEKTRA...
Страница 57: ...57 HL T ELEKTRA SelfTec DW DW F 30...
Страница 58: ...58 SelfTec DW DWF ELEKTRA...
Страница 59: ...59 ELEKTRA UTR60 PRO 16 1200...
Страница 60: ...60 SelfTec DW DWF ELEKTRA 40 120 DIN 16 1200 ELEKTRA ETV 1991...
Страница 61: ...61 5 1000 0 M...
Страница 62: ...62 SelfTec DW DWF ELEKTRA PE...
Страница 63: ...63 ELEKTRA ELEKTRA SelfTec DW 2 DW F c 1 a b 2 ELEKTRA 3 a b c d 4 ELEKTRA...
Страница 64: ...64 SelfTec DW DWF ELEKTRA ELEKTRA...
Страница 65: ...E mail P o 2...
Страница 66: ...M M M C 1000 50 W...
Страница 67: ...ESG PL 427 Grupa V5 02 20 0 b www elektra eu...