![Elektor 1SD 510 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/elektor/1sd-510/1sd-510_operating-and-assembly-instructions-manual_2386333010.webp)
10
Typ Nr.
kW cos kW cos
Hz min
-1
min
-1
Hz
Mot. EN 60034-1 IP W-Kl.F
V V
A A
D-73760 Ostfildern
Germany
Operating and assembly instructions SD
www.elektror.com
0241
18 07.16/06
EN
CONTENT
1 MACHINE SPECIFICATIONS
2 INFORMATION ON TRANSPORT, HANDLNG AND
STORAGE OF THE MACHINE
3 INFORMATION ON PUTTING INTO SERVICE
4 INSTRUCTIONS FOR OPERATION AND USE
5 INSTRUCTIONS FOR MAINTENANCE
6 SAFETY RELATED INFORMATION ON TAKING OUT
OF OPERATION AND REMOVAL
7 LIABILITY AND EXCLUSION OF LIABILITY
8 DECLARATION OF INSTALLATION CONFORMITY
PURSUANT TO ANNEX II 1 B
9 TECHNICAL SPECIFICATIONS
10 BROKEN VIEW DRAWING
11 GENERAL SPARE PARTS LIST
These Operating Instructions must be available to operating
personnel at all times. Read these Operating and Assembly
Instructions carefully before installing and putting the side
channel blower into service.
Subject to change without prior notice. If in any doubt, the
manufacturer should be consulted. This document is protect-
ed by copyright. It must not be disclosed to third parties with-
out our express written consent. Any form of duplication or
recording and storage in electronic equipment is forbidden.
1 MACHINE SPECIFICATIONS
Please refer to the cover sheet for our address.
For the area of validity of these Operating and Assembly In-
structions, please refer to the Declaration of Installation Con-
formity contained in Annex II 1 B.
The technical speci
fi
cations on pages 20-25 apply to the
standard version. Your side channel blower’s speci
fi
cations
may differ from these speci
fi
cations (refer to nameplate). If
this is the case, please refer to the enclosed, additionally ap-
plicable documents or your own applicable Operating and
Assembly Instructions.
Nameplate
The data on the rating plate is applicable to connection,
maintenance and ordering of spare parts. Also refer to the
nameplate for the serial number of the appliance and its year
of manufacture.
1.1 Designated use
Operation of the side channel blower is only permissible
within the limits speci
fi
ed on the nameplate. The information
in the following sections must be noted and observed.
The side channel blowers are exclusively designed for con-
veying gaseous media without solids. Any solid matter or im-
purities in the medium to be conveyed must be
fi
ltered out
before they enter the side channel blower.
Use of the blowers for
• aggressive,
• abrasive,
• sticky,
• toxic,
• potentially explosive or
• very moist
media is not permissible.
The permissible conveyed medium temperature for the
standard version is -20 °C to +40 °C. Solid particles or con-
taminants must be removed by a
fi
lter unit before entering
the side channel blower.
The ambient temperature must not 40 °C or under-
shoot a minimum of –20 °C.
The side channel blower is not suitable for installation in the
open air or in potentially explosive atmospheres.
The side channel blower is fundamentally designed for S1
operation (continuous operation). However, a maximum of
30 switching operations per hour are permitted. Remodelling
and modi
fi
cation of the side channel blower are not permit-
ted.
Special versions
for applications not mentioned above are available on re-
quest. Remodelling and modi
fi
cation of the blower are not
permitted. In the case of special equipment, the enclosed
supplementary Operating and Assembly Instructions must
be observed and adhered to. The supplementary instructions
differ in certain respects from these Operating and Assembly
Instructions.
Elektror blowers offer a high level of operational reliability.
As the blowers are high-powered machines, the safety in-
structions must be strictly observed in order to avoid injuries,
damage to objects and to the machine itself.
Special designs
Can be provided upon request for applications in conditions
beyond those described in these instructions. In the case of
special equipment, the enclosed supplementary Operating
and Assembly Instructions must be observed and adhered
to. The supplementary instructions differ in certain respects
from these Operating and Assembly Instructions, or are out-
side their area of applicability.
1.2 Mechanical hazards
The mechanical hazards in Elektror side channel blowers
have been minimised in accordance with the current state
of the art, as well as the requirements for safety and health
protection. To eliminate any further risk on the part of the op-
erator, we recommend that suitable protective gear be used
and worn during all lifecycle phases of the appliance (please
refer to the instructions below).
1.3 Danger of hand injury
The rotating parts inside the appliance pose a high risk of
injury during operation. Before opening, reaching in or insert-
ing tools into the appliance, always shut it down and wait
until all moving parts come to a standstill. Make sure the ap-
pliance is reliably protected against restarting while work is
in progress.
Also make sure that no hazardous situation can occur as a
consequence of restarting after shutdown, e.g. as a result of
a power cut or blockage.
1.4 Weight and stability
Beware of falling hazards during transportation and installa-
tion in particular. Refer to 2.1 – Transportation and handling,
as well as 3.2 – Installation and assembly.
Содержание 1SD 510
Страница 17: ...17 Operating and assembly instructions SD www elektror com 024118 07 16 06 EN...
Страница 26: ...26 024118 07 16 06...
Страница 27: ...27 024118 07 16 06...