43
495
First Digit: Detailed Display
The keypad can be programmed to show the detailed display at all times or only when the
system is disarmed.
First digit value:
0 – Detailed display only when system disarmed.
1 – Detailed display at all times.
Second Digit: Fire Sensor Reset and Bell Muting for Listen-In Applications
The second digit of this address concerns the following:
•
Power reset for latching smoke detectors – an activated fire sensor can be reset in two
ways. The fire sensor can be reset manually (SELECT, 43)
or the system can be
programmed to automatically reset fire sensors. In both cases, power is restored 15
seconds after the zone has been reset.
•
Bell Muting for Listen-In applications – the bell is not sounded until after a message has
been sent to the central station.
Note: In the event that the telephone line has been
disconnected, the bell is sounded immediately even if bell muting is activated.
Second digit value:
Fire Sensor Reset
Bell Muting
Value
User initiated
Off
0
On
1
Automatic
Off
2
On
3
496
First Digit: Police Key Operation and Remote Programming Communication Speed
The following two options are available at the first digit of this address:
•
The Police key can be programmed to generate a silent or audible alarm.
•
The remote programming speed can be set to either 110 BPS or 300 BPS.
First digit value:
Remote Programmer tel.
Communication speed
Police Key alarm
Value
300 BPS
silent
0
audible
4
110 BPS
silent
8
audible
C
Second Digit: Remote Programming Communication Options
The following options are available at the second digit of this address:
•
The panel can be programmed to enable RP access 24 hours a day or only when all of the
sub-systems are disarmed.
•
The panel can be programmed to enable RP access to be established directly or using the
RP callback feature.
•
The number of rings after which the panel picks up can be set to 1, 3, 7 or 17 rings
Second digit value:
Remote
Prog.
Access
Remote
Prog.
Comm.
Number
of
Rings
Value
Remote
Prog.
Access
Remote
Prog.
Comm.
Number
of
Rings
Value
1
0
1
8
direct
3
1
direct
3
9
call
7
2
call
7
A
24 hours
17
3
disarmed
17
B
1
4
1
C
callback
3
5
callback
3
D
7
6
7
E
17
7
17
F