42
492
Periodic Test Time Setting (Hour)
The periodic test time is set at two addresses, 492 and 493. The hour at which the test will take
place is programmed at this address.
Note: If either the 6-hour or 12-hour test has been
programmed this is the time of the first test. If the 1-hour test has been programmed,
only the minutes setting needs to be defined (Address 493).
Select a two digit value from the following table:
Time
Value
Time
Value
Time
Value
Time
Value
00:00
00
06:00
06
12:00
0C
18:00
12
01:00
01
07:00
07
13:00
0D
19:00
13
02:00
02
08:00
08
14:00
0E
20:00
14
03:00
03
09:00
09
15:00
0F
21:00
15
04:00
04
10:00
0A
16:00
10
22:00
16
05:00
05
11:00
0B
17:00
11
23:00
17
493
Periodic Test Time Setting (Minutes)
Enter a hexadecimal value between 0-59 using the hexadecimal conversion chart in Appendix B.
ADDRESSES 494-496: MISCELLANEOUS
494
First Digit: Arming Options
The first digit of this address offers the following options:
•
Auto unbypass upon disarm – the control panel automatically unbypasses all bypassed
zones when the system is disarmed.
•
Send ‘Arm’ only if all systems armed – the control panel only sends the arming event
code message when all existing sub-systems are armed. The panel sends this message
with the account number for the last sub-system to be armed.
•
Auto arming at the end of closing window – if the system has not been armed by the end
of the closing window, the control panel automatically arms itself.
•
Force Arm – the panel can be programmed to enable or disable forced arming.
First digit value:
Auto unbypass
upon disarm
Send ‘Arm’ only if
all systems armed
Auto arming at the
end of closing window
Force Arm
Value
No
No
0
No
Yes
1
Yes
No
2
No
Yes
3
No
No
4
Yes
Yes
5
Yes
No
6
Yes
7
No
No
8
No
Yes
9
Yes
No
A
Yes
Yes
B
No
No
C
Yes
Yes
D
Yes
No
E
Yes
F
Second Digit: Arming Ring
The control panel can be programmed to sound the bell/siren for 1 second on arming each
system or only after all sub-systems have been armed.
Second digit value:
0 – no arming ring
1 – 1 second ring after arming of every system
5 – 1 second ring only after all systems are armed