3208GLD

3208GLD

Installation, Operation

Installation, Operation

and Programming

and Programming

E L E C T R O N I C S   L I N E ’ S   T E C H N I C A L   S U P P O R T   D E P A R T M E N T :  (972)-3-9211110

Electronics Line (E.L.) Ltd. reserves the right to change the information within this manual without prior notice.

ZI0084A (12/98)

Electronics Line (E.L.) Ltd.

www.elecline.com

Содержание Summit 3208GLD

Страница 1: ...amming and Programming E L E C T R O N I C S L I N E S T E C H N I C A L S U P P O R T D E P A R T M E N T 972 3 9211110 Electronics Line E L Ltd reserves the right to change the information within this manual without prior notice ZI0084A 12 98 Electronics Line E L Ltd www elecline com ...

Страница 2: ...2 ...

Страница 3: ... Partitioning 19 3 11 Tests 20 3 12 Additional Operations 20 Chapter Four Programming 23 4 1 General 23 4 2 Guide to Programming 23 4 3 Programming Procedure 23 4 4 Programming Parameters 24 Appendix A Troubleshooting 45 Appendix B Hexadecimal Conversion Chart 46 Glossary 47 INTRODUCTION About the Summit 3208GLD Installation Operation and Programming Manual This manual is designed to help you the ...

Страница 4: ...user code 3 to 6 Authorization levels 15 Open Close Windows Number of windows 1 opening window 1 closing window for each day of the week per sub system Window sizes 15 min 30 min 45 min 60 min Remote Programming Equipment Remote Programmer software package Access Direct Password Callback Off hook Current Consumption Control Panel Approximately 130mA 3108 LCD Keypad 20mA without backlight 60mA with...

Страница 5: ...e zones can be used for detectors protecting the area in which a keypad has been installed or the area crossed in order to reach the keypad Common Zone A common zone belongs to all systems An alarm will only be generated from a common zone if all the sub systems are armed Common zones are generally used in partitioned systems where a corridor is shared by more than one protected area 24hr zones 24...

Страница 6: ...grammed at address 197 Telephone 4 is designed for use with this feature as it is the only telephone number that can be easily programmed by the user without the need to enter programming mode Telephone Line Supervision Approximately 20 seconds after the telephone line is cut all keypads sound a trouble beep and the message Telephone Comm Failure appears on LCD keypads 1 4 Remote Programming Elect...

Страница 7: ...s entry and exit scheduling requirements If required the user can activate the Late to Close command to extend the closing window period for that day The user may opt to program an auto arming time at the end of a closing window so that the system automatically arms itself at a set time This prevents situations where the system is left unarmed at the end of the day Latch Key The latch key feature ...

Страница 8: ...ing Software 3911 Up Downloading Remote Programmer RS232 Cable 12Vdc Adapter for Remote Programmer 12Vdc 7Ah battery 3722 15Vac 30VA Transformer 2 2 Mounting the Keypad Both the LCD and LED keypads are supplied configured to keypad address 1 in unsupervised mode To connect the keypad s you will need a small flat head screwdriver The maximum recommended distance between the control panel and the ke...

Страница 9: ...esses 132 139 for keypad system allocation System 1 Zone Expander A System 2 Zone Expander B System 3 Zone Expander C System 4 Zone Expander D Note If zone expander A is not in use the control panel s 8 onboard zones are displayed from a System 1 keypad Keypad supervision A supervised keypad will generate an alarm should it become disconnected from the control panel To configure the keypad supervi...

Страница 10: ...phone J4 or 8 POSITION TELEPHONE SOCKET Attach the incoming telephone line and telephone according to the instructions provided in the Installation manual Connect to Earth LED SYSTEM STATUS INDICATOR On Telephone Tone Detection Off System in Communication Flashing Dialing Flashing 1 pulse sec Standby 12V 7Ah BATTERY Use POWERSONIC PS 1270 or YUASA NP7 12 Replace the battery every 3 5 years Long Ra...

Страница 11: ...nal at 1A max including keypads and detection devices for 4 hours standby For CSFM Fire applications 220mA max including keypads and smoke detectors for 24 hours standby Microphone Terminal 23 Microphone input for listen in applications software dependant Smoke Detector Power Output Terminals 24 25 These terminals provide up to 100mA for powering latching smoke detectors The smoke detector output ...

Страница 12: ...s fuse use a bel 5MF3 or other 3A 250V fuse F3 AUX Power Output Protection Fuse Protects terminals 6 keypad power 21 AUX output and 24 smoke detector power output To replace this fuse use a bel 5MF1 6 or other 1 6A 250V fuse MAKE SURE YOU REPLACE A FUSE WITH THE CORRECT RATING 2 6 Turning on the System Once all of the systems components are properly connected to their destination terminals the Sum...

Страница 13: ...nes have been bypassed The Bypass LED and the relevant zone LEDs blink to indicate that zones have been bypassed TROUBLE Blinks if a trouble situation exists within the system telephone communication failure Status Indicators ARMED On when the system is armed off when the system is disarmed Note If the keypad is programmed to display all systems the Armed LED lights up only when all systems are ar...

Страница 14: ...back to the main menu when scrolling or programming Note If one key arming is enabled the user can arm the system using the STAY and AWAY keys without having to enter a user code 3 3 System Status Displays On the LED keypad system status is displayed using the eight zone LEDs as well as the Ready Program Bypass and Trouble LEDs LEDs 1 8 represent alarm situations from the corresponding zone The ot...

Страница 15: ...o perform a command on the control panel Direct commands LCD and LED keypads Menu selections LCD keypad only Direct Command Codes To perform a direct command 1 Press SELECT 2 Enter the operation code for the desired command refer to the Command Codes table below 3 If prompted to enter an authorized user code an acknowledgment tone is sounded to indicate that the command has been performed Command ...

Страница 16: ...ULT PROG 1 22 NORMAL ARM 425 SYSTEM TEST 73 LOAD DEFAULT PROG 2 23 LATE TO CLOSE 426 BATTERY TEST 74 REMOTE PROGRAMMING 3 BYPASS 43 FIRE SENSOR RESET 741 OFF HOOK 31 BYPASS ZONE 44 BELL CANCEL 742 CALLBACK 32 UNBYPASS ZONE 45 STOP COMMUNICATIONS 8 AUX RELAY 33 CHIME ON 46 FOLLOW ME 83 RESET RELAY 34 CHIME OFF 5 USER CODES 84 SET RELAY 39 UNBYPASS ALL 6 VIEW LOG 9 ACCESS CONTROL 4 SERVICE 61 VIEW L...

Страница 17: ...perations of Level 4 view log Follow me telephone number programming and access control Level 6 Operations of Level 5 Zone bypass unbypass clock setting late to close clear log remote programming and stop call Level 7 Operations of Level 6 User code programming Level 8 Same as Level 7 Level 9 Operations of Level 7 Tests Level 10 Operations of Level 9 Programming Level 11 Not available at this time...

Страница 18: ...ange the value of the current field enter the required value 6 Press AWAY to exit user code programming or MENU NEXT to program the next user code Note A user cannot program a code to a higher access level or to a sub system other than the one to which their code belongs Additionally a user cannot view user codes assigned to a higher access level The system accepts the first user code it recognize...

Страница 19: ... Armed LED to stop flashing and zone in alarm messages to be cleared 3 10 System Partitioning The Summit 3208GLD can be operated in partitioned mode where the system is separated into a maximum of four sub systems A sub system is created when at least one zone has been assigned to it The following section describes how certain elements of the system are affected by system partitioning Zones Each z...

Страница 20: ...itiated The report code for this message is at address 251 or 285 Note The control panel seizes the telephone line to run this test System Test To perform a system test Press SELECT 4 2 5 or select System Test from the Test menu the system tests the control panel s electronic circuitry Should the LCD display the message System Failure contact our technical support department Battery Test To perfor...

Страница 21: ...and Q to switch to tone dialing DTMF after a short delay the Program LED turns off Examples To program telephone number 921 1110 using DTMF dialing enter Q9211110 To dial telephone number 9211110 in pulse dialing and then switch to tone dialing to access extension 231 after a pause key in 9211110 Q231 Up to 16 digits can be entered including pauses and tone dialing switches Q The Q key will appear...

Страница 22: ...elease the door latch from the keypad by activating a relay programmed to Access Control mode see address 477 A relay is controlled by its corresponding keypad For example Keypad 1 controls Relay 1 Keypad 2 controls Relay 2 and so on Note Keypad 8 cannot be used to operate this feature as it has no relay assigned To activate an access control relay 1 Press SELECT 9 2 Enter an authorized user code ...

Страница 23: ...ata from the programming form into the control panel To program the Summit 3208GLD using the 3108 LCD keypad 1 Press SELECT 7 1 to enter programming mode 2 Enter an authorized user code 3 Enter a 3 digit parameter address the keypad displays the selected address within a group of related parameters zones telephone numbers routing etc For example if a zone parameter address is selected the four par...

Страница 24: ...amming parameters The following table lists the addresses for each group of programming parameters ADDRESSES PARAMETERS ADDRESSES PARAMETERS 000 127 Zone Parameters 388 Swinger Parameters 128 131 System Parameters 389 409 Opening Closing Windows 132 139 Keypad Parameters 410 Bell Cut Off 140 179 Telephone Numbers 411 Dealer Lockout Latchkey 180 195 Account Numbers 412 475 Custom LCD Zone Descripto...

Страница 25: ...ORTH 06 46 86 C6 BASEMENT 26 66 A6 E6 NURSERY 07 47 87 C7 BATHROOM 27 67 A7 E7 OFFICE 08 48 88 C8 BEDROOM 28 68 A8 E8 PANIC 09 49 89 C9 BEDROOM 1 29 69 A9 E9 PERIMETER 0A 4A 8A CA BEDROOM 2 2A 6A AA EA POOL 0B 4B 8B CB BEDROOM 3 2B 6B AB EB ROOF 0C 4C 8C CC COMPUTER 2C 6C AC EC ROOM 0D 4D 8D CD CONFERENCE 2D 6D AD ED ROOM 1 0E 4E 8E CE CORRIDOR 2E 6E AE EE ROOM 2 0F 4F 8F CF DINING 2F 6F AF EF ROO...

Страница 26: ...Value Bypassable Chime System Value 1 0 1 8 No 2 1 No 2 9 3 2 3 A No 4 3 Yes 4 B 1 4 1 C Yes 2 5 Yes 2 D 3 6 3 E 4 7 4 F 002 First Digit Zone ID for zone 1 Zone ID is the number that can be sent to identify the zone in event code messages to the central station event oriented event code table Generally the zone ID is the same as the zone number First digit value Enter a value between 0 F for Zone ...

Страница 27: ... Same as above for zone 13 052 055 Same as above for zone 14 056 059 Same as above for zone 15 060 063 Same as above for zone 16 ADDRESSES 064 095 Zones 17 24 These addresses are added to the control panel with either the 3508 or 3528 zone expanders zone expander jumper setting C Zone expanders are programmed at address 476 064 067 Same as above for zone 17 068 071 Same as above for zone 18 072 07...

Страница 28: ...o B No C Continuous No 1 D 3 E Yes No F Second Digit Display Power Trouble Tones and One Key Arming for System 1 The second digit of this address offers options for the display type of each sub system s keypads and the tones sounded for power related trouble conditions One Key Arming allows the user the capability to arm the system using either the STAY or AWAY keys without needing to enter a user...

Страница 29: ...sion Display System Operate System Value 1 1 0 1 1 8 2 2 1 2 2 9 3 3 2 3 3 A No 4 4 3 Yes 4 4 B 1 4 1 C All 2 5 All 2 D 3 6 3 E 4 7 4 F 133 Same as above keypad 2 134 Same as above keypad 3 135 Same as above keypad 4 136 Same as above keypad 5 137 Same as above keypad 6 138 Same as above keypad 7 139 Same as above keypad 8 ADDRESSES 140 179 TELEPHONE NUMBERS Consecutive addresses are used to enter...

Страница 30: ...nable Disable The first digit of this address comprises the following options Dialing Initiation the control panel only dials if a dial tone is detected within the time out programmed at address 197 or allowed anyway after the second time out Dialing Mode the panel can be programmed to use either pulse or tone DTMF dialing Telephone Event Message Enable Disable this option enables or disables tele...

Страница 31: ... according to the requirements of the local telecommunications authority If any problems are experienced please contact Electronics Line Technical Support Dept Second digit value 0 Dial after 1 second 2 second anti jam 1 Dial after 5 seconds 2 second anti jam 2 Dial after 10 seconds 2 second anti jam 3 Dial after 20 seconds 2 second anti jam 4 Dial after 1 second or if dial tone present 2 second a...

Страница 32: ...d data rate should be defined in addition to the event code table Select the second digit value from the following table Event Code Table Data Frequency and Data Rate Options for Pulse Protocols Second digit value Event Code Format Data Frequency Ack Frequency Data Rate Value 1400Hz 10pps 0 1800Hz 20pps 1 2300Hz 10pps 2 Event Oriented 20pps 3 1400Hz 10pps 4 1900Hz 20pps 5 2300Hz 10pps 6 20pps 7 14...

Страница 33: ...227 Event code for zone 25 228 Event code for zone 26 229 Event code for zone 27 230 Event code for zone 28 231 Event code for zone 29 232 Event code for zone 30 233 Event code for zone 31 234 Event code for zone 32 235 Event code for opening disarming 236 Event code for normal closing arming 237 Event code for closing with bypassed zones 238 Event code for perimeter closing STAY arming 239 Event ...

Страница 34: ... code for zone trouble restore battery low 266 Event code for zone tamper 267 Event code for zone tamper restore 268 Event code for zone emergency alarm 269 Event code for opening disarming 270 Event code for normal closing arming 271 Event code for closing with bypassed zones 272 Event code for perimeter closing 273 Event code for LSCP unit tamper 274 Event code for LSCP unit tamper restore 275 E...

Страница 35: ...not call this telephone number 1 Primary telephone number 2 Duplicate telephone number 3 Backup telephone number Note If the Follow me feature is used define this number as a duplicate telephone number Telephone 3 Second digit value 0 Do not call this telephone number 1 Primary telephone number 2 Duplicate telephone number 3 Backup telephone number 297 Message routing for burglary alarms telephone...

Страница 36: ...Delay Time for System 3 381 Exit Delay Time for System 4 ADDRESSES 382 384 ENTRY TIMERS The entry delay timer determines the amount of time the user has to disarm the system before an alarm is generated Three different entry delay times can be programmed and each zone can be assigned one of these delays Enter a hexadecimal value number between 0 255 seconds using the hexadecimal conversion chart i...

Страница 37: ... table The times listed in the rows indicate the center of the window The size of the window can be selected from the columns For example a window starting at 7 30 and ending at 8 30 will be prog rammed as 41 8 00 30 minutes Note To disable an opening or closing window option enter FF Time 15 min 30 min 45 min 60 min Time 15 min 30 min 45 min 60 min 00 00 12 00 60 61 62 63 00 30 04 05 12 30 64 65 ...

Страница 38: ... 3 Second digit value System 4 SATURDAY 406 First digit value System 1 Second digit value System 2 407 First digit value System 3 Second digit value System 4 SUNDAY 408 First digit value System 1 Second digit value System 2 409 First digit value System 3 Second digit value System 4 ADDRESS 410 BELL CUT OFF 410 Enter the desired bell cut off time 1 255 FF seconds ADDRESS 411 DEALER LOCKOUT LATCH KE...

Страница 39: ...Descriptor 4 ADDRESS 476 ZONE EXPANDERS 476 Definition of Zone Expander Modules When installing zone expanders hardwire or wireless the system must be programmed to recognize the existence of the additional zones All defined zone expanders are supervised If a zone expander is disconnected all its zones are opened Note Following any modifications made to this address disconnect and re apply both AC...

Страница 40: ... System 2 alarm Cutoff System 2 disarm 07 Event System 3 alarm System 3 alarm Cutoff System 3 disarm 08 Event System 4 alarm System 4 alarm Cutoff System 4 disarm 09 Event Fire alarm Fire zone in alarm or keypad fire emergency Cutoff 0A Status System 1 status System 1 Not ready Pulsing if system has bypassed zones System 1 ready without bypassed zones 0C Status System 2 status System 2 Not ready P...

Страница 41: ...ontinuous F 479 480 Same as above for Relay 2 and onboard relay K6 481 482 Same as above for Relay 3 483 484 Same as above for Relay 4 485 486 Same as above for Relay 5 487 488 Same as above for Relay 6 489 490 Same as above for Relay 7 ADDRESSES 491 493 PERIODIC TEST Periodic test transmissions are used to check the system s ability to communicate with the central station The frequency of these t...

Страница 42: ...Auto unbypass upon disarm the control panel automatically unbypasses all bypassed zones when the system is disarmed Send Arm only if all systems armed the control panel only sends the arming event code message when all existing sub systems are armed The panel sends this message with the account number for the last sub system to be armed Auto arming at the end of closing window if the system has no...

Страница 43: ...itiated Off 0 On 1 Automatic Off 2 On 3 496 First Digit Police Key Operation and Remote Programming Communication Speed The following two options are available at the first digit of this address The Police key can be programmed to generate a silent or audible alarm The remote programming speed can be set to either 110 BPS or 300 BPS First digit value Remote Programmer tel Communication speed Polic...

Страница 44: ...t located in Appendix B 498 AC restore report delay The AC restore report delay determines how many minutes the panel will wait after AC power has been regained before transmitting a message to the central station Select a value in hexadecimal for the AC restore report delay For hexadecimal value conversions refer to the hexadecimal conversion chart located in Appendix B ADDRESS 499 LISTEN IN TIME...

Страница 45: ...o sound from the bell Blown bell fuse or wrong parameters Replace fuse or program the bell parameters correctly Zone expander does not give any zone indications Zone expander supervision is not programmed Reprogram parameters A single output does not react properly Programming error Correct the programming for the specific relay Wrong alarm or trouble indicator from the zone Wrong zone loop type s...

Страница 46: ...113 71 114 72 115 73 116 74 117 75 118 76 119 77 120 78 121 79 122 7A 123 7B 124 7C 125 7D 126 7E 127 7F 128 80 Dec Hex 129 81 130 82 131 83 132 84 133 85 134 86 135 87 136 88 137 89 138 8A 139 8B 140 8C 141 8D 142 8E 143 8F 144 90 145 91 146 92 147 93 148 94 149 95 150 96 151 97 152 98 153 99 154 9A 155 9B 156 9C 157 9D 158 9E 159 9F 160 A0 161 A1 162 A2 163 A3 164 A4 165 A5 166 A6 167 A7 168 A8 ...

Страница 47: ...voltage Bell Cancel A keypad operation that immediately stops the bell siren Bell Cut Off The programmable amount of time the bell siren is sounded when an audible alarm is generated Bell Muting A feature used in Listen in applications where the bell is not sounded until after a message has been sent to the central station Bell Test A manual test that sounds the bell for 1 second Bypassed Zone Ala...

Страница 48: ...med to initiate an entry delay when opened The entry delay is a pre programmed amount of time that allows the user enough time to enter the protected area and disarm the system without generating an alarm Event Code The code transmitted to the central station when an event occurs Event Log A record of the last 100 events that the system has undergone Exit Delay The amount of time the user has to e...

Страница 49: ...em events and status conditions P Partitioned System A system that is divided into a number of independent sub systems Perimeter Arming See Stay Arming Perimeter Zone A zone intended for detection devices that protect the outer perimeter of the premises These zones are used in conjunction see Stay Arming Periodic Test Test transmission used to check the control panel s capability to communicate wi...

Страница 50: ... that more than one keypad be configured to the same unit address see Keypad Unit Address User Code The code that grants access to certain operational capabilities The operations available to a specific user are dependent on the authorization level assigned to their user code see Authorization Level V View Log An LCD keypad operation that allows the user to view a record of the last 100 events the...

Страница 51: ... all other obligations or liabilities on the part of EL It is the sole warranty and any prior agreements or representations whether oral or written are either merged herein or are expressly canceled EL neither assumes nor authorizes any other person purporting to act on its behalf to modify to change or to assume for it any other warranty or liability concerning its products EL RECOMMENDS THAT THE...