-19-
Address 02: Communication Options
This address consists of the various options used in communication and/or remote
programming. Enter five digits according to the following.
Fifth Digit:
Dialing
0 - Pulse
1 - DTMF
First Digit:
Stop Communications
0 - Disabled
1 - Enabled
Fourth Digit:
Handshake
0 - 1400Hz Handshake
1 - 2300Hz Handshake
Second Digit:
RP Access Type
0 - Passcode
1 - Callback
Third Digit:
RP Access
0 - Disable RP Access
1 - Enable RP Access
Zone Definitions
You can define one of seven response types for each zone. Each zone type can be
programmed as silent or audible, except for Fire which is always audible. A silent zone
will not activate a siren or bell when the zone is tripped.
00 - Perimeter zone with delay (Silent)
10 - Perimeter zone with delay (Audible)
01 - Perimeter zone (Silent)
11 - Perimeter zone (Audible)
02 - Conditional zone (Silent)
12 - Conditional zone(Audible)
03 - Interior zone (Silent)
13 - Interior zone (Audible)
04 - 24hr zone (Silent)
14 - 24hr zone (Audible)
05 - Fast Loop Perimeter Zone (Silent)
15 - Fast Loop Perimeter Zone (Audible)
16 - Fire zone (Audible –
can only be assigned to Zone 1
)
Address 03: Zone 1 Definition
Address 04: Zone 2 Definition
Address 05: Zone 3 Definition
Address 06: Zone 4 Definition