-16-
3.9: Additional Operations
Bell Cancel
To cancel the bell:
•
Enter a valid user code or turn the keyswitch as if disarming the system.
Bell/LED Test
To perform a bell/LED test:
•
Press
4
,
4
,
1
; the siren is sounded and all LEDs on the keypad are lit for a
period of two seconds.
Walk Test
Walk test mode enables you to test peripheral detection devices, such as PIR detectors
and magnetic door contacts. In this mode, when a zone is opened or closed, the keypad
chimes.
To perform a walk test:
1. Press
4
,
4
,
2
.
2.
Enter User Code 1; the Ready, System, Power and Armed LEDs flash to
indicate that the system is in Walk Test mode. To end Walk Test mode, press
#
.
This mode is automatically terminated after 4 minutes.
Note: The Tamper Zone always generates an alarm if opened, even if the system is
in Walk Test mode.
Stop Communications
To cancel the transmission of all unsent messages:
1. Press
ENTER
,
1
.
2. Enter User Code 1; all pending messages are cleared and all communications
stop immediately.
Note: The Stop Communications function is available only if enabled in programming
(Address 02).
Zone Chime On/Off
The keypad can be set to chime when Perimeter With Delay or Perimeter zones are
opened or closed. This feature only functions when the system is disarmed.
To toggle the zone chime On or Off:
•
Press
4
,
6
while the system is disarmed.
The keypad will sound a continuous tone to indicate “Zone Chime ON” or two short
beeps to indicate “Zone Chime OFF”.
Keypad Backlight On/Off
To toggle the backlight of any keypad On or Off:
•
Press and hold down
#
for more than 2 seconds.