3.7: Zone Bypassing/Unbypassing
A bypassed zone is ignored by the system and will not generate an alarm when tripped.
To bypass a zone:
1. Press
4
,
1
.
2. Enter a valid user code; the System LED flashes and the LEDs of any currently
bypassed zones light up.
3. Enter the number of the zone to be bypassed; the corresponding zone LED is lit.
4. Press
#
to exit bypass mode; the bypassed zones flash.
To unbypass a zone:
1. Press
4
, 1.
2. Enter a valid user code; the System LED flashes and the LEDs of any currently
bypassed zones light up.
3. Enter the number of the zone to be unbypassed; the corresponding zone LED
turns off.
4. Press # to exit bypass mode.
Note: Disarming the system automatically unbypasses all bypassed zones.
3.8: Event Logs
The event logs record events that the system has undergone since the last arming. If any
events have been recorded in either event log, the System LED flashes until the relevant
event log has been viewed. In the event that a trouble condition still exists, the System
LED continues to flash until the condition has been remedied.
Emergency/Trouble Event Log
Zone tamper, keypad tamper, keypad trouble or any of the three distress key alarms are
registered in the Emergency/Trouble event log.
To view the Emergency/Trouble event log:
1. Press
4
,
2
; the various trouble conditions are indicated by the zone LEDs. The
following is a summary of the trouble condition that each LED indicates when lit:
1
-
Tamper or Keypad Trouble
2
-
Alarm from P key
3
-
Alarm from F key
4
-
Alarm from E key
2. Press # to exit the event log.
Note: The event logs can only be viewed when the system is disarmed.
Zone Alarm Event Log
The Zone Alarm event log displays the zones from which an alarm was generated since
the system was last armed.
To view the Zone Alarm event log:
1. Press
4
,
3
; an alarm from a specific zone is indicated by the corresponding
zone LED.
2. Press
#
to exit the event log.
Both logs are automatically reset when the system is next armed (at the end of the exit
delay).