4.4 Power and Ground
The requirements for power are shown in
Table 6
. The black with white stripe wire, Pin 7 on the 23-pin
XDI connector, must be grounded. The DFU chassis must also be grounded.
Description
Wire Color
Voltage
Peak Current
(Amps)
“Key On”, switched battery
Yellow
10-18
2
DFU Power
Red w/ white stripe
10-18
10
NOTE:
DFU Power shown is for one DFU. If you are using two DFU’s, you must have two circuits capable
of 10 amps.
NOTE:
24-volt units are available upon special request.
The installation regarding power distribution depends on the user’s preference and needs.
Figures 11 and 12
show the recommended installation.