C: Trigger wheel sensor connector. This connects the XDI main harness to the magnetic sensor on the crank
trigger wheel. This is described in Section 4.3.
D: Additional DFU Cable. This cable is only used for configurations that use a second DFU. This cable is not
included with the XDI. This cable is provided at no additional cost, but it must be requested with the purchase
of the XDI.
The pin-out for the 23-pin AMP connector is shown in
Table 5
.
Pin
Description
Wire Color
1
Coil A1
White
2
Reserved
NA
3
Magnetic Sensor Shield
Bare
4
Reserved
NA
5
Reserved
NA
6
+12V Switched Ignition
Yellow
7
Reserved
NA
8
Coil A2
White
9
Coil B1
Red
10
Magnetic Sensor Ground
Black
11
Magnetic Sensor Signal
Red
12
Reserved
NA
13
External Retard Control
Orange
14
Ground
Black w/ white stripe
15
Coil B2
Red
16
Shield for DFU #1
Bare
17
Coil C1
Black
18
Tachometer
Brown
19
+5V Output
Gray w/ red stripe
20
External Advance Control
Green
21
Advance Output
Pink
22
Coil C2
Black
23
DFU #2 Shield
Bare
4.2 Wiring the DFU’s
4.2.a DFU to XDI
DFU’s are made by Electromotive in two variants: 2-coil and 3-coil. Each coil drives two spark plugs in
waste-spark ignition setups. Two cycle applications will not use waste-spark.
The first step in wiring the DFU’s is to install the ground wire. The DFU’s come from our factory with
a ground wire pre-installed on a tapped, un-anodized hole. This wire MUST be connected to chassis/battery
ground.
NOTE
: Failure to ground the DFU chassis may result in severe electrical shock to the user! Electrical
shock will occur if the DFU is not grounded, and someone touches it while touching chassis ground (with the
engine running). If desired, the ground wire may be relocated elsewhere on the DFU chassis. However,
you
will need to scrape off the anodizing
from the chassis at the point of contact, since the anodizing acts as an
electrical insulator. Also, loose coil screws may cause an electrical shock as well, since they must be grounded
to the case at all times.
Always make sure that both the coil screws and the ground wire are securely fastened.
After the DFU has been grounded, the rest of the wiring may begin. You will receive the DFU cable
Table 5
–
23-pin AMP connector pinout
Содержание xdi
Страница 31: ...XDI Manual Version 1 8 Page 31 2017 Electromotive Inc Appendix B Quick Reference Sheets ...
Страница 32: ...XDI Manual Version 1 8 Page 32 2017 Electromotive Inc ...
Страница 33: ...XDI Manual Version 1 8 Page 33 2017 Electromotive Inc ...
Страница 34: ...XDI Manual Version 1 8 Page 34 2017 Electromotive Inc ...
Страница 35: ...XDI Manual Version 1 8 Page 35 2017 Electromotive Inc ...
Страница 36: ...XDI Manual Version 1 8 Page 36 2017 Electromotive Inc ...