44
Steam connection
9 Steam connection
Inlet pipes connected to the machine must be equipped with a manual shut-off valve to facilitate
installation and servicing.
The connection hose must be of type ISO/1307- 1983 or equivalent.
Connection size at filter:DN 15 (BSP 1/2").
Demount the top panel (A).
Demount the casing (B.
27
A
B
fig.6600
Mount the nipple to the steam valve.
Mount the steam valve on the machine.
Mount nipple, strainer and elbow. Note the direction of the strainer.
Mount steam hose to the elbow.
Check that there are no sharp angles or bends on the connected steam hose.
28
fig.5862A