3.3.1 Casting a plinth
A plinth should be used where the existing floor is less than 100 mm thick or in order to ensure that
the machine is above the level of any water leakages.
The plinth should be approximately 150 - 200 mm in height.
⑤
150-200 mm /
5 7/8-7 7/8 inch
40 mm /
1 9/16 inch
fig.5462
Proceed as follows:
• Break up the existing floor to a depth of approx. 75 mm and check that the sides of the hole are
tapered outward so that the longest side at the bottom measures 120 mm more than at the top.
⑥
75
a
a + 120
fig.0899
• Make the mould for the plinth.
• Moisten the hole well and apply cement to the sides and bottom.
• 4 bolts must be set into the concrete of the machine base. The bolts need to project 40 mm out
of the base. Pour the concrete into the prepared base mould and make sure that the surface is
level. Check the previous table for the correct position of the bolts.
• The concrete should be left to set for at least two days before mounting the machine on the plinth.