Installation manual
Washer extractor
W575N, W585N, W5105N, W5130N, W5180N,
W5250N, W5330N
Type W3...
438 9055-30/EN
Original instructions
2013.02.21
Страница 1: ...Installation manual Washer extractor W575N W585N W5105N W5130N W5180N W5250N W5330N Type W3 438 9055 30 EN Original instructions 2013 02 21 ...
Страница 2: ......
Страница 3: ...24 6 1 Connection of the hoses 24 6 2 Electrical connection of external dosing system 25 6 2 1 Machine with connectors 25 6 2 2 Machine without connectors 26 6 2 3 Outputs 27 6 2 4 Inputs 28 7 Drain connection 29 8 Electrical connection 30 8 1 Electrical installation 30 8 2 Electrical connections 31 8 3 Machine connection 36 8 3 1 Single phase connection 36 8 3 2 Three phase connection 37 8 4 Func...
Страница 4: ...Contents 11 Function check 47 The manufacturer reserves the right to make changes to design and component specifications ...
Страница 5: ... the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision DO NOT MODIFY THIS APPLIANCE All external equipment which is connected to the machine must be CE EMC approved and connected using an approved shielded cable All external equipment must be connected according to t...
Страница 6: ... 5 Hot water 6 Water re use 7 Drain valve 8 Liquid detergent supply 9 Electrical connection 10 Steam connection mm A B C D E F G H W575N 660 1094 1131 355 686 835 80 1034 W585N 660 1157 1132 355 726 836 80 1035 W5105N 720 1187 1200 365 697 920 80 1119 W5130N 720 1326 1201 365 787 920 80 1119 mm I J K L M N O W575N 217 124 1014 914 278 101 199 W585N 217 124 1015 915 278 103 199 W5105N 224 124 1099 ...
Страница 7: ...g panel 2 Door opening W5180N 395 mm 3 Detergent container 4 Cold water 5 Hot water 6 Water re use 7 Drain valve 8 Liquid detergent supply 9 Electrical connection 10 Steam connection mm A B C D E F G H W5180N 751 1431 1344 435 875 1048 81 1249 mm I J K L M N O P W5180N 297 132 1229 1129 278 104 231 217 ...
Страница 8: ... Detergent container 4 Cold water 5 Hot water 6 Water re use 7 Drain valve 8 Liquid detergent supply 9 Electrical connection 10 Steam connection mm A B C D E F G H W5250N 830 1594 1425 470 949 1129 80 1328 W5330N 910 1679 1464 500 1034 1034 80 1367 mm I J K L M N O P Q W5250N 327 233 1288 1203 278 100 264 162 287 W5330N 347 247 1327 1247 278 104 210 162 287 ...
Страница 9: ...loor load at max extraction kN 1 6 1 9 1 7 3 1 1 9 2 5 2 4 3 1 2 9 3 9 3 8 4 9 4 6 5 6 2 3 Connections W575N W585N W5105N W5130N W5180N W5250N W5330N Water valves DN BSP 20 3 4 20 3 4 20 3 4 20 3 4 20 3 4 20 3 4 20 3 4 Recommended water pressure kPa 200 600 200 600 200 600 200 600 200 600 200 600 200 600 Functioning limits for water valve kPa 50 1000 50 1000 50 1000 50 1000 50 1000 50 1000 50 1000...
Страница 10: ...e is determined by using ISO 3747 2012 According to test code IEC 60704 2 4 the sound power level at extraction and during washing are according to the table W575N W585N W5105N W5130N W5180N W5250N W5330N Wash dB A 65 64 64 64 69 67 68 Extraction dB A 69 69 70 69 72 71 74 ...
Страница 11: ...crate or box Remove packing from the machine Remove the front and rear panel Remove the bolts between the machine and pallet There is one to the right in the front of the machine and another diagonally opposed to it at the back of the machine fig 7651 Remove the machine from the pallet Note When moving the machine handle it with care Place the machine on its final position ...
Страница 12: ...r drain or open drain The machine should be positioned so that there is plenty of room for working both for the user and service personnel The figure shows minimum distance to a wall and or other machines 500 mm 20 inch 25 mm 1 inch 25 mm 1 inch fig W00176D ...
Страница 13: ...p 1 for the expander bolts in the positions shown G H I 1 1 A F D E B C fig 0948A mm A B C D E F G H I W575N 685 660 495 395 115 635 W585N 725 660 495 445 115 665 W5105N 700 720 575 385 120 695 W5130N 785 720 575 495 120 760 W5180N 875 750 635 570 120 855 W5250N 950 830 715 635 125 955 W5330N 1035 910 790 695 135 1050 810 10 95 After the machine has been placed over the other four bolts place the ...
Страница 14: ...lance in the drum fig 5463A After the machine has been in use for a while check and re tighten the nuts if necessary Floor In this type of machine the drum is attached directly to the frame As a result the floor under the machine must be stable enough to absorb the dynamic forces generated during spin cycles For that reason the mounting bolts must be cast into the floor material itself When fixing...
Страница 15: ...t the sides of the hole are tapered outward so that the longest side at the bottom measures 120 mm more than at the top 75 a a 120 fig 0899 Make the mould for the plinth Moisten the hole well and apply cement to the sides and bottom 4 bolts must be set into the concrete of the machine base The bolts need to project 40 mm out of the base Pour the concrete into the prepared base mould and make sure ...
Страница 16: ... bolt into the hole so that the glass ampule is broken and its contents mixed 5 Rotate the bolt to correct depth Note Do not rotate the bolt against the concrete bottom Check that the chemicals have filled the hole completely 6 Remove the drilling machine with the mounting tool Hold the bolt with one hand Let the bolt harden before the machine is mounted 1 2 3 4 5 6 fig 5917A Time for hardening du...
Страница 17: ...pply sealant to the hole cut in the vinyl floor covering Insert the washer Use sealant to seal around the washer between the vinyl and the washer 4 Put the machine into place Check that the machine is in level If it is not use spacers where required between floor and machine If chemical anchors are used do not use the nut and washer supplied with them Fix the machine in place using the washers and...
Страница 18: ...to a floor drain or open drain The machine should be positioned so that there is plenty of room for working both for the user and service personnel The figure shows minimum distance to a wall and or other machines 1000 mm 39 3 8 inch 50 mm 1 15 16 inch 50 mm 1 15 16 inch fig W00176E ...
Страница 19: ...ine is placed in level from side to side as well as front to rear If the machine is not properly levelled it may result in out of balance without a real out of balance in the drum fig 5463A After the machine has been in use for a while check and re tighten the nuts if necessary Floor In this type of machine the drum is attached directly to the frame As a result the deck under the machine must be s...
Страница 20: ...eck that the sides of the hole are tapered outward so that the longest side at the bottom measures 120 mm more than at the top 75 a a 120 fig 0899 Make the mould for the plinth Moisten the hole well and apply cement to the sides and bottom 4 bolts must be set into the concrete of the machine base The bolts need to project 40 mm out of the base Pour the concrete into the prepared base mould and mak...
Страница 21: ...5837C mm A B C D E F G H W575N 660 685 495 80 395 115 W585N 660 725 495 80 445 115 W5105N 720 700 575 75 385 120 W5130N 720 785 575 75 495 120 W5180N 750 875 635 55 570 120 W5250N 830 950 715 55 635 125 W5330N 910 1035 790 60 695 135 mm I J K L M W575N 30 455 85 W585N 30 505 85 W5105N 10 30 445 85 W5130N 10 30 555 85 W5180N 10 30 630 90 W5250N 10 30 695 95 W5330N 10 30 755 105 ...
Страница 22: ...ter types to be connected to the machine Information is also available on the panel above the connections Water type Water connection 1 W575N W585N Cold W575N W585N 1 Cold 2 1 W575N W585N W5105N W5130N Cold and hot W575N W585N W5105N W5130N 1 Cold 2 Hot 2 1 3 W5180N W5250N W5330N Cold and hot W5180N W5250N W5330N 1 Cold 2 Hot 3 Cold for detergent container Hot There is also an extra water valve wh...
Страница 23: ...Water connection 23 For installations in UK WRAS approved machines must be equipped with check valves on both cold and hot water inlet ...
Страница 24: ...o the siphon breaker A 17 mm used for external dosing systems or systems for re use of water B 6 mm used for external dosing systems only C Only used for external liquid manifold Separate instructions enclosed when ordering A B C Always connect hoses on connections A with a hose clamp For connections B if the hoses are made of a soft material such as silikon or similair use a cable tie to fasten t...
Страница 25: ...e machine s incoming terminal block or to the edge connectors on the I O board 6 2 1 Machine with connectors Connect the external dosing system to connections A and B on the machine Connect the signal cable to B and the power supply to A A B 1 2 3 4 1 2 3 4 5 7 6 9 fig 6598 1 N 2 L 4 Ground 11 N 18 Program run 12 Signal 1 13 Signal 2 14 Signal 3 15 Signal 4 16 Signal 5 ...
Страница 26: ... to the I O board which is located to the right of the incoming power supply The I O board has edge connectors for connecting external dosing systems Edge connectors on the I O board can be loosened for connecting cables fig 6572 11 N 18 Program run 12 Signal 1 13 Signal 2 14 Signal 3 15 Signal 4 16 Signal 5 ...
Страница 27: ...x load on the outputs 0 5 A Signals for external liquid supplies 1 5 are connected to 12 16 where connector 12 Signal 1 13 Signal 2 14 Signal 3 15 Signal 4 16 Signal 5 fig 6236B 6M14 6F01 6R01 6F02 Other programs Signal 1 Pre wash Pre wash Pre wash Pre wash Signal 2 Main wash Main wash Main wash Main wash Main wash Signal 3 Softener Softener Softener Softener Softener Signal 4 Mop last rinse Desin...
Страница 28: ...y be connected if the program is to pause e g while detergent is being dosed The figure shows an example of engaging a 24V pause signal The program will pause for as long as the pause signal remains activated high Dosing system Common 0V P ause signal 24V DC 3 8 fig 6266 Connection 7 If this is connected an error message will be displayed if any of the chemical tanks are empty The program will con...
Страница 29: ...ber hose to the machine s drain pipe ensuring a downward flow from the machine Avoid sharp bends which may prevent proper draining The drainage pipe should be located over a floor drain drainage channel or the like so that the distance between the outlet and the drain is at least 25 mm fig 5330 ...
Страница 30: ...ised installation company to ensure that the appropriate type of breaker is chosen and that the dimensioning is correct for maximum reliability connect only one machine per earth leakage circuit breaker it is important that the earth wire is properly connected In instances where the machine is not equipped with an omni polar switch one must be installed beforehand In accordance with the wiring rul...
Страница 31: ...240V 1 50 60 4 5 5 4 4 9 5 7 25 220 240V 1 50 60 6 3 7 5 6 6 7 8 35 220 240V 3 50 60 2 5 3 0 2 9 3 3 10 220 240V 3 50 60 4 0 4 3 4 3 4 7 16 220 240V 3 50 60 4 5 5 4 4 9 5 7 16 220 240V 3 50 60 6 3 7 5 6 6 7 8 25 380 415V 3 50 60 2 5 3 0 2 8 3 3 10 380 415V 3 50 60 3 6 4 3 4 0 4 7 10 380 415V 3 50 60 4 5 5 4 4 8 5 7 10 380 415V 3 50 60 6 3 7 5 6 6 7 8 16 440 480V 3 60 7 5 7 8 16 Electric heated 415...
Страница 32: ...4 5 5 4 4 9 5 7 25 220 240V 1 50 60 6 3 7 5 6 6 7 8 35 220 240V 3 50 60 2 5 3 0 2 9 3 3 10 220 240V 3 50 60 4 0 4 3 4 3 4 7 16 220 240V 3 50 60 4 5 5 4 4 9 5 7 16 220 240V 3 50 60 6 3 7 5 6 6 7 8 25 380 415V 3 50 60 2 5 3 0 2 8 3 3 10 380 415V 3 50 60 3 6 4 3 4 0 4 7 10 380 415V 3 50 60 4 5 5 4 4 8 5 7 10 380 415V 3 50 60 6 3 7 5 6 6 7 8 16 440 480V 3 60 7 5 7 8 16 Electric heated 415V 3 240V 1 50...
Страница 33: ... 8 8 10 4 50 220 240V 3 50 60 2 5 3 0 3 0 3 5 16 220 240V 3 50 60 4 4 5 2 4 8 5 7 20 220 240V 3 50 60 6 3 7 5 6 8 8 0 25 220 240V 3 50 60 8 4 10 0 8 8 10 4 35 380 415V 3 50 60 2 5 3 0 3 0 3 4 10 380 415V 3 50 60 4 4 5 8 4 8 5 7 16 380 415V 3 50 60 6 3 7 5 6 7 7 9 16 380 415V 3 50 60 8 3 10 0 8 8 10 4 20 440 480V 3 60 7 5 8 0 16 440 480V 3 60 10 0 10 4 20 415V 3 240V 1 50 60 7 5 5 0 7 9 5 4 16 25 E...
Страница 34: ... 0 3 0 3 4 10 380 415V 3 50 60 4 4 5 2 4 8 5 7 16 380 415V 3 50 60 6 3 7 5 6 7 7 9 16 380 415V 3 50 60 8 3 10 0 8 8 10 4 20 440 480V 3 60 7 5 8 0 16 440 480V 3 60 10 0 10 4 20 415V 3 240V 1 50 60 7 5 5 0 7 9 5 4 16 25 Electric heated 415V 3 240V 1 50 60 10 0 6 7 10 4 6 9 20 35 Non heated Steam heated 200V 3 50 60 0 8 10 W5180N Heating alternative Main voltage Hz Heating power kW Total power kW Rec...
Страница 35: ...3 50 60 1 1 10 Max permitted impendance 0 26 Ohm W5330N Heating alternative Main voltage Hz Heating power kW Total power kW Recommended fuse A 200V 3 50 60 14 4 15 6 50 220 240V 3 50 60 16 6 19 8 17 8 21 0 63 380 415V 3 50 60 16 5 19 7 17 1 20 9 50 Electric heated 440 480V 3 60 21 0 22 8 22 2 24 0 50 200V 3 50 60 1 2 10 Non heated Steam heated 440 480V 3 60 1 2 10 Max permitted impendance 0 26 Ohm...
Страница 36: ...36 Electrical connection 8 3 Machine connection 8 3 1 Single phase connection Connect the earth and other two wires as shown 1NAC T1 T2 T3 L1 N N L2 L3 1AC T1 T2 T3 L1 N N L2 L3 1AC L1 L2 ...
Страница 37: ...Electrical connection 37 8 3 2 Three phase connection Connect the earth neutral and phase wires as shown 3AC T1 T2 T3 L1 N N L2 L3 3AC L1 L2 L3 3N AC T1 T2 T3 L1 N N L2 L3 3N AC N L1 L2 L3 ...
Страница 38: ...chematic can be one of the following 8 4 1 External coin meter Central payment 2A The signal received from external coin meters must be a pulse between 300 3000 ms 500 ms is recommended with a minimum pause of 300 ms 500 ms is recommended between two pulses 21 fig 6606A ...
Страница 39: ...ayment system must transmit a start pulse to the machine The start pulse can be either 230V or 24V In order to receive a feedback signal once the machine has started 230V or 24V must be connected to connection 19 The feedback signal on connection 18 remains active high during the entire program 22 fig 6316A ...
Страница 40: ...hine once permission has been granted to start the machine The signal must remain active high until the machine starts A feedback signal will be present on connection 18 and remain active high whilst the machine door is closed but the program has not started The feedback signal is powered by 230V or 24V from connection 19 23 fig 6313A ...
Страница 41: ...ines with the coin program package By maintaining an active high signal on connection 5 Price red the price of the program can be reduced This function has a number of uses including providing reductions during a specific period of the day Whilst the signal remains active high the price of the program is reduced by the percentage entered in the price programming menu 24 fig 6314A ...
Страница 42: ...Con 108 1 2 Con 109 1 2 3 4 5 6 RE106 RE105 RE104 RE103 RE102 Con 107 1 2 3 RE101 Inp Con 115 Function I O s PTD5 Type of I O card 5V Start permitted Central booking payment 230V 0V 24V 24V Start permitted Central booking payment Neutral Line Com 24V Com 100 240V Blocking of start Heating pause Liq det empty Temporary pause Common outputs Power for outputs Common Liquid det sign 1 Liquid det sign ...
Страница 43: ...mber of uses including providing reductions during a specific period of the day Whilst the signal remains active high the price of the program is reduced by the percentage entered in the price programming menu 26 1 P U M P D R A IN 1 H O T 1 C O L D 1 CPU 2 3 1 2 3 4 1 2 3 4 D R A IN P BUS P BUS 1 2 3 3 In p u t P ric e re d u c tio n 1 C o m 5 2 4 V A C D C 2 C o m 1 0 0 2 4 0 V A C fig 6636 ...
Страница 44: ...of type ISO 1307 1983 or equivalent Connection size at filter DN 15 BSP 1 2 Demount the top panel A Demount the casing B 27 A B fig 6600 Mount the nipple to the steam valve Mount the steam valve on the machine Mount nipple strainer and elbow Note the direction of the strainer Mount steam hose to the elbow Check that there are no sharp angles or bends on the connected steam hose 28 fig 5862A ...
Страница 45: ... Connect ground cable to the terminal ground connection Connect the HEAT cable connector to the HEAT terminal on the I O board 29 HEAT fig 6604 Steam pressure required minimum 50 kPa 0 5 kp cm2 maximum 800 kPa 8 kp cm2 recommended 600 kPa 6 kp cm2 Note A steam heated machine is only intended to use clean steam ...
Страница 46: ...irst time you will be forced to select language for the machine Select language from the list on the display This will be the language that all display messages program names etc will be presented in For more information about changing language and other functions please refer to the programming and configuration manual ...
Страница 47: ... wash and start a program Check that the drum rotates normally and that there are no unusual noises Check that there are no leaks in water supply drain connections Check that water passes through the detergent container Check that the door cannot be opened during a program Ready to use If all tests are OK the machine is now ready to be used If some of the tests failed or deficiencies or errors are...
Страница 48: ...lastpage Electrolux Laundry Systems Sweden AB 341 80 Ljungby Sweden www electrolux com laundrysystems Share more of our thinking at www electrolux com ...