15
Safety instructions for the
installer
•
This appliance corresponds to the type EN 60
335-2-6 with respect to protection against fire.
Only units of this kind may be fitted one-sided to
adjoining high-level cabinets or walls.
•
When fitted in combustible material, the NIN 2000,
section 4.2.2 and the fire-protection regulations of
the association of local fire insurance companies
must be observed without fail.
•
Limit to room width 550 mm, height 127 mm from
lower side of grill plate, depth 560 mm from rear
with a working surface depth of 600 mm. Combus-
tible walls and ceilings must be provided with a
flame-retardant lining above the grill plate in con-
formity with the official fire regulations for the rele-
vant area.
•
Protection against contact must be ensured by the
installation.
Electrical connection
•
Electrical connection must be made by a certified
installer.
•
The mains connection to the built-in switchbox
must be made with the existing connecting cable
and corresponding to the connection diagram. An
isolating device with at least 3 mm contact open-
ing to disconnect the appliance from the mains
supply at all poles simultaneously should be pro-
vided in the permanent home installation conform-
ing with NIN 2000.
•
Warning!
While being serviced the appliance
must be disconnected from the power supply. The
rating plate is fitted on the underside of the built-in
switchbox.
•
Before putting into operation detach any protective
foil from the grill plate.
•
After connecting to the power supply all grill plates
should be switched on briefly (approx. 2 minutes)
in succession at the 100 °C position to check their
readiness for operation.
Rating plates
Versions with two thermostats
Versions with one thermostat
Model Code
TY 58 CN/Vi
PNC
949 480 191
00
Model Code
TY 38 CN/Vi
PNC
949 480 190
00